GOLDEN TANDOORS GT -610AG, GT-710AG Installation & Operation Manual

GOLDEN TANDOORS
GAS TANDOOR OVEN
Installation & Operation Manual
GT -610AG & GT-710AG
This manual must be retained for future reference
FOR YOUR SAFETY
Do not store, spray or use gasoline, flammable
appliance while it is operation.
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation and operator’s instructions thoroughly before installing or servicing this equipment.
CAUTIONS
APPROVAL
NUMBER: GMK10422
ANSI / NSF STD 4
SERVICE DATA & CONTACT
GOLDEN TANDOORS
GT-610AG & GT-710AG Tandoor Oven Installaon Manual
SERVICE CONTACT
Service & Technical Support is available through Golden Tandoors Australia. For a list of dealers visit www.goldentandoors.com.au You may call Golden Tandoors Australia for support on +613 9796 4583 between 9:00am - 5:00pm AEST Monday - Friday. After office hours leave a voice mail & we shall revert back to you as soon as possible.
Leave your complete phone number with serial number of the product. You can email us for any query at sales@goldentandoors.com.au
DISCLAIMER
Although the information and recommendations in this manual are presented in good faith and believed to be correct, Golden Tandoors and/its parent company make no representations or warranties as to the completeness/accuracy of the information.
Information is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. In no event will Golden Tandoors and/or its parent company be responsible for damages of any nature whatsoever resulting from the use of or reliance upon information from this site or the products to which the information refers.
Golden Tandoors and/or its parent company does not warrant the accuracy or timeliness of the materials in this manual and has no liability for any errors or omissions in the materials and recipes.
THIS MANUAL IS PROVIDED ON AN "AS IS" BASIS. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCTS TO WHICH INFORMATION REFERS.
GAS CODE LIMITATIONS
The installation of this appliance must conform with local codes, or in the absence of local codes, with the Australian Standard AS4563-2004 Commercial Catering Gas Equipment (Barbeque Grillers) and AS/NZS 5601.1:2013 Gas Installations – Part 1: General Installations, as applicable including: The appliance and its individual shutoff valve (supplied by others) must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ½ psi (3.45kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve (supplied by others) during any pressure testing of the gas supply piping system at test pressure, equal to or less than ½ psi (3.45kPa).
The product comes with an INSTALLATION MANUAL and an
OPERATOR’S MANUAL
READ BOTH MANUALS CAREFULLY BEFORE USING THE PRODUCT
RETAIN BOTH MANUALS FOR FUTURE REFERENCE
GOLDEN TANDOORS
GT-610710AG-2016V1-E
WARNING
Improper installation, adjustment,
alteration, service or maintenance can
cause property damage, or serious injury.
Read the installation, operating
and maintenance instructions thoroughly
before use, installing or servicing this
equipment.
Note: The information contained herein is confidential and is the property of the manufacturer. It is not to be disclosed, disseminated or used except for the purpose for which it is provided.
Contents
Gas Specifications 1
Minimum Clearances 2
Ventilation Requirements 3
Specifications 4
Unpacking 5
Site Requirements 6
Installation Procedures 7
Operation Procedure 8
First Burning 9
Maintenance 10
Troubleshooting 12
Technical Service Contact 13
GT-610AG & GT-710AG Tandoor Oven Installation & Operation Manual
GOLDEN TANDOORS
GT-610AG & GT-710AG Tandoor Oven Installation & Operation Manual
GAS SPECIFICATIONS
GT-610710AG-2016V1-E
1
Gas Inlet
BOTTOM VIEW
Gas Inlet Locaon
Control Box
Towel Hanger
Rear
Clearance
Bumper
Locking Castor Height Adjustable
GOLDEN TANDOORS
GT-610AG & GT-710AG Tandoor Oven Installation & Operation Manual
MINIMUM CLEARANCES
GT-610710AG-2016V1-E
2
Dimensions
Rear Bumper LHS + RHS
110mm Clearance
DO NOT REMOVE
Gas Inlet
SIDE VIEW
TOP VIEW
FRONT VIEW
BOTTOM VIEW
Model
Width (mm)
W
Depth (mm)
D
Height (mm) H Mouth Opening (mm)
M
Weight (Kg)
GT-610AG 610 610 740 315 190
GT-710AG
710 710 740 345 250
GOLDEN TANDOORS
GT-610710AG-2016V1-E
Clearance Requirements
GT-610AG & GT-710AG Tandoor Oven Installation & Operation Manual
Ventilation Requirements
3
SIDE VIEW OF GAS TANDOOR
Diagram not to scale, descriptive only
Gas Hose Restraint
The oven is mounted on
castors, commercial flexible
hose with a minimum of 3/4” (1.9cm) must be used along with a quick connect
device. (Not supplied with
the product)
The restraint supplied with
the Tandoor oven must be
used to limit the movement
of the unit so that no strain
is placed upon the flexible connector. With the restraint fully stretched the connector
should be easy to install and
quick connect.
The restraint should be attached without damaging the building. Do not use gas
piping or electrical conduit
for the attachment of the
permanent end of the
restraint. Use anchor bolts in
concrete or cement block. If
you have a wooden wall do not use the tandoor near it as the tandoor must not be
used near combustible
surfaces or materials
including walls.
Warning !!
If the restraint is disconnected for any reason it must be reconnected when the oven is returned to its original position.
1350mm Clearance minimum required from top of burner to bottom of canopy filter as per AS/NZS Standards.
Ensure left to right minimum clearance of 300mm from wall or any other objects.
NOTE: Appliance must be located on Fire Proof Base
WARNING: Avoid locating Tandoor next to solid fuel, stoves, ovens, or grills.
Installation Requirements
Installer to observe the following standards:
1. Increase minimums to 600mm if butted up close to glass windows, mirrors or display equipment, etc.
2. Kitchen Exhaust Canopy in accordance with AS/NZS 1668 Parts 1 & 2
3. Gas Installation Standard AS/NZS 5601
4. Relevant Authorities (Council, Building, Health, etc.)
Fire Proof Floor
TOP VENTILATION
SIDE VIEW OF GAS TANDOOR
1350mm
110MM
FRONT VIEW OF GAS TANDOOR
300MM300MM
TOP VENTILATION