Mounting strap
(circular)
2ea @3/8 x 3mm 1ea @3/8 x 65mm
Reason why ( missing, scratched, broken glass, bent, bad finish)
This fixture assembled PO:__________ Date: ________
to be filled out by retailer
For Customer Service, contact the place of purchase to arrange for replacement parts.
Company Name:_______________________Co. Account #:_____________
PARTS & ASSEMBLY SHEET
Read and review installation instruction sheet before
assembling the fixture.
Fixture Name: Mirabella 7644-SF GA
Please review the parts listing and check for all parts before assembling the fixture. If any parts are missing or
damaged, please note onthis sheet and contact the place of purchase to arrange for replacement parts.
PARTS LIST
Wire connectors Deco nut
1ea @4" 3ea P4 Orange 5ea 10x 9.5mm
Canopy
1ea @5-5/8"X1-5/8" 2ea 8/32" x 1" 1ea @3/8 x 50mm
Chain Mounting screw
1ea 6ft x3.8mm 2ea 8/32" x 1-1/4" 1ea @3/8 x 40mm x 5mm
Chain connector Hex nut Nipple
2ea @3X38mm
w/ ground screw
1ea 3/4"X4" 2ea @8/32" x 8mm
Part Needed Quantity
Screw
Top loop
Canopy loop
with Collar
(CRYSET-7644-SF)
IXTURE ASSEMBLY INSTRUCTIONS
7644-SF GA
ASSEMBLING THE FIXTURE as Semi flush (Fig. 1)
1. Place shade (N) over the nipple of the Frame (M) and
secure with Deco Nut (E).
2. Attach hooks at both ends of the Decorative Chain (O)
to Frame (M) as shown in the diagram.
3. Install the light bulbs in accordance with the fixture's
specifications.
(DO NOT EXCEED MAXIMUM WATTAGE RATING)
7644-SF GA PartsInstallation_20120406m(ok)

For Customer Service, contact the place of purchase to arrange for replacement parts.
Fixture Name: Mirabella 7644-SF GA
ASSEMBLING THE FIXTURE as Chain hung (Fig. 2)
1. Remove the Circular st r ap from top of Fixture and
replace the long mounting s cr ew s with two short screws
to hold the Deco nuts (E) in place on the fixture
Bottomop cap (M).
2. Feed the fixture wires thr ough the Top loop (J) and
pull the wires until taut.
3. Then screw the Top Loop (J) to the threaded center
column of Frame (M) until tight.
4. Place shade (N) over t he nipple of the Frame (M)
and secure Deco Nut (E).
5. By measuring determine correct number of links
needed for proper hanging height. Use a pair of pliers
to open one link of the Chain (K) then remove the
excess Chain (K) and discard it.
6. Use one chain connector (L) to attach one end of the
chain to the Top loop (J) and close the chain connector.
7. Feed the fixture wires thr ough the Chain (every three
links) and pull the wires until t aut.
8. Slip Canopy loop collar (H) over the chain, then do
the same with the canopy ( G).
9. When ready to complete the installation Use the
other chain connector and attach the other end of the
chain to the canopy loop (F) and close the chain
connector.
10. Make sure the weight of the chandelier will be
supported by the chain-not the electrical wire.
* You may now install the fixture.
Note: Complete these remaining steps after the
fixture is hung.
11. Pull the straight edges of the hook that sits at the
end of decorative chain (N) outward until it opens,
insert crystal ball (Q) into the opening and then close
the hook by pressing the edges together over the
loop at the top of the crystal as shown in the
diagram.
12. Install the light bulbs (not provided) in
accordance with the fixture's specifications.
(DO NOT EXCEED MAXIMUM WATTAGE RATING)
7644-SF GA PartsInstallation_20120406m(ok)

INSTALLATION INSTRUCTIONS
HANGING THE FIXTURE as Semi flush (Fig. 1)
CONNECTING THE WIRES (Fig. 2)
BLACK to BLACK (or SMOOTH) and WHITE to WHITE (or RIBBED).
NOTE: Twist the wires together in the same direction you twist the wire
FINISHING THE INSALLATION (Fig.3)
against the ceiling by threading the decorative nuts on (E) until tight.
THE JUNCTION BOX AND TEST THE FIXTURE.
BARE COPPER
(Ground)
GREEN
(Ground)
FIXTURE WIRES
SMOOTH (BLACK)
RIBBED (WHITE)
BLACK
WHITE
HOUSE WIRES
Fixture Name: Mirabella 7644-SF GA
WARNING ! SHUT OFF POWER AT FUSE OR CIRCUIT BREAKER.
1. Carefully remove the new fixture from the carton and the yellow bag
that holds all your parts. Check that all parts are included as shown in
the illustration and parts list.
2. Shut off power at the circuit breaker and remove the old fixture from
ceiling, including the old mounting strap.
3. The Circular Strap (B) contains several pairs of threaded holes, find
the pair of holes that match the hole spacing in your fixture Canopy (F)
and thread the two Mounting Screws (A) half way into the Mounting
Strap (A) facing down, Secure in place with hex nuts. These will have
their threaded ends protrude through the two holes in the fixture
canopy(F).
4. Place the Mounting Strap (B) over the junction box.
5. Attach the Mounting Strap (B) to the Junction Box using the two
mounting screws (C). Tighten the screws (C) securely with screw
driver.
For Semi Flush / Convertible Light Fixture
6. Attach the power supply wires to the fixture lead wires by connecting
7. Attach the GROUND wire(GREEN or COPPER) from the Junction
Box and the fixture Ground wire to the green Ground Screw on the
Mounting Bracket (B) or connect both wires together using the correct
size of wire connectors.
connector onto the wires.
8. Tuck these wire connections neatly into the Junction Box.
9. Place the fixture’s Canopy (F) over the Mounting Strap (B) and over
the Mounting Screws (A), adjust the fixture Canopy until the Mounting
Screws (A) protrude out from the canopy (D) and secure the fixture
10. Install the light bulbs and glass shade as per the fixture assembly
sheet.
YOUR INSTALLATION IS NOW COMPLETE. RETURN POWER TO
For Customer Service, contact the place of purchase to arrange for replacement parts.

For Customer Service, contact the place of purchase to arrange for replacement parts.
13. Raise Canopy (G) t o the ceiling and secur e in place by tightening the
14. Install the light bulbs and glass shade as per the fixture assembly sheet.
INSTALLATION INSTRUCTIONS
canopy loop and nipple and into the outlet box.
CONNECTING THE WIRES (Fig 2)
BLACK to BLACK (or SMOOTH) and W H ITE to WHITE (or RIBBED).
HANGING THE FIXTURE (Fig.1)
junction box Screws (E). Tighten screw securely with screw driver.
L
B
C
A
JUNCTION BOX
(CEILING)
D
E
F
H
J
CHAIN
G
BARE COPPER
(Ground)
GREEN
(Ground)
FIXTURE WIRES
SMOOTH (BLACK)
RIBBED (WHITE)
BLACK
WHITE
HOUSE WIRES
Fixture Name: Mirabella 7644-SF GA
For Chandelier Light Fixture
WARNING ! SHUT OFF POWER AT FUSE OR CIRCUIT BREAKER.
HANGING THE FIXTURE (Fig. 1)
1. Carefully remove the new fixture fr om the carton and the yellow
1. Carefully remove the new fixture from the c arton and the yellow bag that
bag that holds all parts. Check that all parts are included as shown in
holds all parts . Check that all par ts are included as shown in the illustr ation and
the illustration and parts list.
parts list .
2. Shut off the power at the circuit breaker and remove old f ixtur e
2. Shut off the power at the circuit breaker and remove old fixture from ceiling,
from ceiling, including the old m ounting s trap.
including the old mount ing strap.
3. Thread Nipple(C) into Canopy Loop (F) until snug.
3. Thread Nipple(C) into Canopy Loop (F) until snug.
4. Thread other end of the Nipple (C) with Canopy Loop attached into Mounting
4. Thread other end of the Nipple (C) with Canopy Loop attached
into Mounting Strap (D).
Strap (D).
5. Place Lock Washer (B) over end of Nipple (C) protruding through Mounting
5. Place Lock Washer (B) over end of Nipple (C) protruding thr ough
Mounting Strap (D) and thread Hex Nuts (A) onto Nipple until tight.
Strap (D) and thread Hex Nuts (A) onto Nipple unti l tight.
6. Take this mounting strap assembly and m ount to ceiling juncti on box with
6. Take this mounting strap assem bly and m ount to ceiling junc tion
box with junction box Screws (E). Tighten screw securely with screw
driver.
7. Unscrew the Canopy l oop collar(H )fr om the Canopy loop. Take the canopy
7. Unscrew the Canopy loop collar (H )from the Canopy loop. T ak e
the canopy and pass over the Canopy loop. approx im at ly one half of
and pass over the Canopy loop. approximatly one half of the canopy loop
the canopy loop exterior threads should be ex posed. Adj us t until
exterior threads s hould be exposed. Adjust until desired height is reached. *the
desired height is reached. *the Canopy loop collar should fit snugly
on the Canopy loop after the canopy is installed. Remove Canopy
Canopy loop collar should fit snugly on the Canopy loop af ter the canopy is
and Canopy lock collar.
installed. Remove Canopy and C anopy lock collar.
8. Assemble the fixture and have an assistant or secur e support hold
8. Assemble the fixture and have an assistant or secure support hol d the weight
the weight of the fixture while you complete the wiring c onnec tions.
of the fixture while you complete the wiring connections.
9. Thread the fixture wires and ground wire of the assembled fixture
9. Thread the fixture wi res and ground wire of the as sembled fixture through t he
through the canopy loop and nipple and into the outlet box.
CONNECTING THE WIRES (Fig. 2)
10. Attach the power supply wires to the fixture lead wires by
connecting BLACK to BLACK (or SMOOTH) and WHITE to WHITE
10. Attach the power supply wires to the f ixture lead wires by connec ting
(or RIBBED).
11. Attach the GROUND wire(GREEN or COPPER) f r om the
11. Attach the GROUND w ire(GREEN or COPPER) f rom the Junction Box and
Junction Box and the fixture Ground wire to the green Gr ound Scr ew
on the Mounting Bracket (D) or connect both wires together us ing
the fixture Ground wir e to the green Ground Screw on the Mounting Bracket (D )
the correct size of wire connectors.
NOTE: Twist the wires together in the same direction you twist the
or connect both wires together using the correct size of wire connectors .
wire connector onto the wires.
NOTE: Twist the w ires together in the same direction you twist the wire
12. Tuck these wire connections neatly into the J unct ion Box.
connector onto the wires.
13. Raise Canopy (G) to the ceiling and secure in place by tightening
12. Tuck these wi re connections neatl y into the Junction Box.
the Canopy loop collar (H) into the Canopy Loop (F) .
14. Install the light bulbs and shade as per the fixture assembly
Canopy loop collar(H) into the Canopy Loop(F)
sheet.
YOUR INSTALLATION IS NOW COMPLETE.
RETURN POWER TO THE JUNCTION BOX
AND TEST THE FIXTURE.