
PARTS & ASSEMBLY SHEET
1. Feed the fixture wires through the Top loop (J) and pull the
Fixture Name: Mayfair 7116-3P LC
This fixture assembled PO:__________ Date: ________
Notice:
damaged, please note onthis sheet and contact the place of purchase to arrange for replacement parts.
PARTS LIST
Canopy Mounting Screws Top loop
1ea ∅5-3/4"*H1-1/2" 2ea 8#32-IP*1" 1ea 1/8-IP*H60mm
Chain Wire connectors Nipple
1ea 6ft ∅3.8 3ea P3 Orange 1ea 1/4-IP*H60mm
Chain connector
2ea ∅5.8*H61mm 1ea ∅1-1/8"*H42mm 1ea W4-1/8"*E1"*H5mm
Nipple
1ea 1/8-IP*H120mm 2ea 1-1/2-IP*H2mm
1ea ∅3-1/4"*H25mm 1ea 1/8-IP*H4mm
Please review the parts listing and check for all parts before assembling the fixture. If any parts are missing or
Company Name:_______________________Co. Account #:_____________
to be filled out by retailer
Canopy loop
with Collar
Metal washer &
Plastic washer
Hex NutBottom cap Finial
Mounting strap
Deco Screw
3ea 5/32-IP*H9mm
1ea 1/8-27-IP*H39mm
Part Needed Quantity
Part Needed Quantity
Reason why ( missing, scratched, broken glass, bent, bad finish)
Comments
F
IXTURE ASSEMBLY INSTRUCTIONS
Read and review installation instruction sheet before
assembling the fixture.
ASSEMBLING THE FIXTURE (Fig.1)
wires until taut.
2. Then screw the Top Loop (J) to the threaded center
column of Frame (M) until tight.
3. Gently spread the arms until evenly spaced if arms are
packed closed.
4. Align the top of Scroll arm over the arm connector holes
(X) at top of socket assembly and secure in place with the
Deco screws (U).
NOTE: I
NSTALL THE GLASS ASSEMBLY AFTER
Fig 1
7116-3P LC
THE FIXTURE IS HUNG.
For Customer Service, contact the place of purchase to arrange for replacement parts.
7116-PartsInstallation_20110106m.xls

PARTS & ASSEMBLY SHEET
washer (O), plastic washer (P), glass shade (S) thread the
washer (X), metal washer (Y), hex nut (T) , bottom cap (V)
Fixture Name: Mayfair 7116-3P LC
ASSEMBLING THE FIXTURE (Fig.2)
5. By measuring determine correct number of links needed
for proper hanging height. Use a pair of pliers to open one
link of the Chain (C2) then remove the excess Chain (C2)
and discard it.
6. Use one chain connector (E2) to attach one end of the
chain to the Top loop (J) and close the chain connector.
7. Feed the fixture wires through the Chain (every three
links) and pull the wires until taut.
8. Slip Canopy loop collar (B2) over the chain, then do the
same with the canopy.
9. When ready to complete the installation Use the other
chain connector and attach the other end of the chain to
the canopy loop (A2) and close the chain connector. Make
sure the weight of the chandelier is supported by the chain-
not the electrical wire.
Fig 2
* You may now install the fixture.
Note: Complete these remaining steps after the fixture is
hung.
10. Thread the threaded rod/nipple (N) onto the socket
assembly coupler, secure with a hex nut.
11. Install the light bulbs in accordance with the fixture's
specifications.
12. Thread on the Nipple (N) in this order: hex nut, metal
nipple through the hole in bottom of glass shade, plastic
and secure in place with the finial (Z).
(DO NOT EXCEED MAXIMUM WATTAGE RATING)
For Customer Service, contact the place of purchase to arrange for replacement parts.
7116-PartsInstallation_20110106m.xls

YOUR INSTALLATION IS NOW COMPLETE. RETURN
the weight of the fixture while you complete the wiring connections.
INSTALLATION INSTRUCTIONS
Fixture Name:
Mayfair 7116-3P, 6, GM4, ND3, 9, D5,M1L LC
WARNING ! SHUT OFF POWER AT FUSE OR CIRCUIT BREAKER.
HANGING THE FIXTURE (Fig 1)
1. Carefully remove the new fixture from the carton and the yellow bag
that holds all parts. Check that all parts are included as shown in the
illustration and parts list.
2. Shut off the power at the circuit breaker and remove old fixture from
ceiling, including the old mounting strap.
3. Thread Nipple(C) into Canopy Loop (F) until snug.
4. Thread other end of the Nipple (C) with Canopy Loop attached into
Mounting Strap (D).
5. Place Lock Washer (B) over end of Nipple (C) protruding through
Mounting Strap (D) and thread Hex Nuts (A) onto Nipple until tight.
6. Take this mounting strap assembly and mount to ceiling junction box
with junction box Screws (E). Tighten screw securely with screw driver.
7. Unscrew the Canopy loop collar(H )from the Canopy loop. Take the
canopy and pass over the Canopy loop. approximatly one half of the
canopy loop exterior threads should be exposed. Adjust until desired
height is reached. *the Canopy loop collar should fit snugly on the
Canopy loop after the canopy is installed. Remove Canopy and
Canopy lock collar.
8. Assemble the fixture and have an assistant or secure support hold
For Chandelier Light Fixture
Fig. 1
9.Thread the fixture wires and ground wire of the assembled fixture
through the canopy loop and nipple and into the outlet box.
CONNECTING THE WIRES (Fig 2)
10. Attach the power supply wires to the fixture lead wires by
connecting BLACK to BLACK (or SMOOTH) and WHITE to WHITE (or
RIBBED).
11. Attach the GROUND wire(GREEN or COPPER) from the Junction
Box and the fixture Ground wire to the green Ground Screw on the
Mounting Bracket (D) or connect both wires together using the correct
size of wire connectors.
NOTE: Twist the wires together in the same direction you twist the wire
connector onto the wires.
12. Tuck these wire connections neatly into the Junction Box.
13. Raise Canopy (G) to the ceiling and secure in place by tightening
the Canopy loop collar (H) into the Canopy Loop (F)
14. Install the light bulbs and glass shade as per the fixture assembly
sheet.
For Customer Service, contact the place of purchase to arrange for replacement parts.
Fig. 2
POWER TO THE JUNCTION BOX AND TEST THE
FIXTURE.