PARTS & ASSEMBLY SHEET
1. By measuring determine correct number of rods and
additional Rods may be
Fixture Name: Rockefeller 2488-M1L FI & 3711-M1L CB
This fixture assembled PO:__________ Date: ________
Notice: Please review the parts listing and check for all parts before assembling the fixture. If any parts are missing or
damaged, please note onthis sheet and contact the place of purchase to arrange for replacement parts.
PARTS LIST
Canopy Mounting Screws Top loop
1ea 6-1/2"*H1-1/2" 2ea 8#32-IP*1" 1ea 1/8-IP*H77mm
Chain Wire connectors Nipple
1ea 2ft 3.8 3ea P3 Orange 1ea 1/4-IP*H60mm
Chain connector
2ea 5.8*H61mm 1ea 1-1/8"*H42mm 1ea W4-1/8"*E1"*H5mm
Rod
3ea 11.7*H12"
Part Needed Quantity
Part Needed Quantity Reason why ( missing, scratched, broken glass, bent, bad finish) Comments
Company Name:_______________________Co. Account #:_____________
to be filled out by retailer
Canopy loop with Collar
Mounting strap
FIXTURE ASSEMBLY INSTRUCTIONS
Read and review installation instruction sheet before assembling the fixture.
2488-M1L FI & 3711-M1L CB
ASSEMBLING THE FIXTURE (Fig.1)
chain needed for proper hanging height. There are 2 ft of chain and 2 optional 12" rods included.
2. To shorten the fixture slide the excess 12" rods off the wire.
3. To lengthen the fixture thread the additional rods onto the wire or substitute longer chain for the 2 foot length included.
NOTE: INSTALL THE GLASS ASSEMBLY AFTER
THE FIXTURE IS HUNG.
For Customer Service, contact the place of purchase to arrange for replacement parts.
24883711-PartsInstallation_20110105m.xls
Fig 1
These two Rods may be removed or
added. ROD-12 CB or FI * additional chain may be added. CHAIN-CB or FI * *available for purchase separately
Page 2
chain connector and attach the other end of the chain to the
11. Make sure the weight of the chandelier will be supported
PARTS & ASSEMBLY SHEET
Fixture Name: Rockefeller 2488-M1L FI & 3711-M1L CB
4. Feed the fixture wires through the Top loop (J) and rods
(M), pull the wires until taut.
5. Then screw the Top Loop (J) to the threaded center
column of Frame (M) until tight.
6. By measuring determine correct number of links needed
for proper hanging height. Use a pair of pliers to open one
link of the Chain (C2) then remove the excess Chain (C2)
and discard it.
7. Use one chain connector(E2) to attach one end of the
chain to the Top loop (J) and close the chain connector.
Fig 2ASSEMBLING THE FIXTURE (Fig.2)
Fig 3
8. Feed the fixture wires through the Chain (every three
links) and pull the wires until taut.
9. Slip Canopy loop collar (B2) over the chain, then do the
same with the canopy (F2).
10. When ready to complete the installation Use the other
canopy loop (A2) and close the chain connector.
by the chain-not the electrical wire.
* You may now install the fixture.
Note: Complete these remaining steps after the fixture is
hung.
12. Place the Glass Shades(O) over the Threaded
sockets(P),secure the Glass Shades (O) by
threading by the Socket Rings (N) until tight.
13. Install the light bulbs in accordance with the
fixture's specifications.
(DO NOT EXCEED MAXIMUM WATTAGE RATING)
For Customer Service, contact the place of purchase to arrange for replacement parts.
24883711-PartsInstallation_20110105m.xls
Page 3
YOUR INSTALLATION IS NOW COMPLETE. RETURN
the weight of the fixture while you complete the wiring connections.
INSTALLATION INSTRUCTIONS
Fixture Name: Rockefeller 2488-6, 9, 3P, D5, ND3, M1L FI & 3711-6, 9, 3P, D5, ND3, M1L CB
For Chandelier Light Fixture
WARNING ! SHUT OFF POWER AT FUSE OR CIRCUIT BREAKER.
HANGING THE FIXTURE (Fig.1)
1. Carefully remove the new fixture from the carton and the yellow bag
that holds all parts. Check that all parts are included as shown in the
illustration and parts list.
2. Shut off the power at the circuit breaker and remove old fixture from
ceiling, including the old mounting strap.
3. Thread Nipple(C) into Canopy Loop (F) until snug.
4. Thread other end of the Nipple (C) with Canopy Loop attached into
Mounting Strap (D).
5. Place Lock Washer (B) over end of Nipple (C) protruding through
Mounting Strap (D) and thread Hex Nuts (A) onto Nipple until tight.
6. Take this mounting strap assembly and mount to ceiling junction box
with junction box Screws (E). Tighten screw securely with screw driver.
7. Unscrew the Canopy loop collar(H )from the Canopy loop. Take the
canopy and pass over the Canopy loop. approximatly one half of the
canopy loop exterior threads should be exposed. Adjust until desired
height is reached. *the Canopy loop collar should fit snugly on the
Canopy loop after the canopy is installed. Remove Canopy and
Canopy lock collar.
8. Assemble the fixture and have an assistant or secure support hold
Fig. 1
9.Thread the fixture wires and ground wire of the assembled fixture
through the canopy loop and nipple and into the outlet box.
CONNECTING THE WIRES (Fig 2)
10. Attach the power supply wires to the fixture lead wires by
connecting BLACK to BLACK (or SMOOTH) and WHITE to WHITE (or
RIBBED).
11. Attach the GROUND wire(GREEN or COPPER) from the Junction
Box and the fixture Ground wire to the green Ground Screw on the
Mounting Bracket (D) or connect both wires together using the correct
size of wire connectors.
NOTE: Twist the wires together in the same direction you twist the wire
connector onto the wires.
12. Tuck these wire connections neatly into the Junction Box.
13. Raise Canopy (G) to the ceiling and secure in place by tightening
the Canopy loop collar(H) into the Canopy Loop(F)
14. Install the light bulbs and glass shade as per the fixture assembly
sheet.
For Customer Service, contact the place of purchase to arrange for replacement parts.
Fig. 2
POWER TO THE JUNCTION BOX AND TEST THE
FIXTURE.