Reason why ( missing, scratched, broken glass, bent, bad finish)
For Customer Service, contact the place of purchase to arrange for replacement parts.
Read and review installation instruction sheet before
PARTS & ASSEMBLY SHEET
Company Name:_______________________Co. Account #:_____________
to be filled out by retailer
Fixture Name: Valencia 2049-9 FB
This fixture assembled PO:__________ Date: ________
Notice: Please review the parts listing and check for all pa rts before as sembling the fixture. If any parts are miss ing or
damaged, please note on this s heet a nd c ontac t the place of purchase to arrange for replacement parts.
PARTS LIST
Canopy (G)
1ea 5.2" Dia*1.1"
Chain
1ea 6FT*Φ4.2mm
Chain Connector (I)
2 ea Φ4*H55mm
Mounting Strap (D)
1ea 3/4"*1"
Top Loop (J)
1ea W44*H69mm
Bottom Cap (P)
1ea W38*H22mm
Part Needed Quantity
Hex Nut (B)
2ea 3/8"*H3mm
Threaded Ring (H)
1ea Φ23-16T*H5mm
Screw Collar Loop (F)
1ea 3/8"*H42.4mm
Green Ground Screw
1ea #8-32N*H10mm
Crystal (S)
9ea W21*75Lmm
Finial ( R)
1ea W27xH37mm
Nipple (C)
1ea 3/8"*H45mm
Junction Box Screw (E)
2ea #8-32N*H32mm
Wire Connectors
3ea P3
Center Column (L)
1ea W32xH95mm
Threaded Rod (N)
1ea 3/8"*H440mm
Glass
4ea
W135*H415mm one smaller
FIXTURE ASSEMBLY INSTRUCTIONS
2049-9 FB
assembling the fixture.
1. Remove the Top cap (K) off the center column, slide
the three glass panels (M) down through the top of the
Glass cage and secure with metal clips.
2. Replace the top cap, open the doop to place the
smaller glass panel (M), secure with clips.
NOTE: INSTALL THE GLASS ASSEMBLY BEFORE
THE FIXTURE IS HUNG.

PARTS & ASSEMBLY SHEET
Fixture Name: Valencia 2049-9 FB
ASSEMBLING THE FIXTURE (Fig. 2)
3. Place and tighten the Threaded Nipple (N) on top
of hex nut (O).
4. Then slide the Box (X), Lids (T), Center Column
(L) along with the glass cage (K) on top of each
other accordingly. Settle the Top cap in place.
5. Then tighten everything together with the Top
Loop (J).
NOTE: SOME ADJUSTMENT MAYBE NEEDED ON
THE DECORATIVE METAL SCROLLING OF THE
ARMS. THESE ARE FLEXIBLE, BEND GENTLY
TO DESIRED SHAPE.
6. By measuring determine correct number of links
needed for proper hanging height. Use a pair of
pliers to open one link of the Chain then remove the
excess Chain and discard it.
7. Use one Chain Connector (I) to attach one end of
the Chain to the Top Loop (J) and close the Chain
Connector (I)
8. Feed the fixture wires through the Chain (every
three links) and pull the wires until taut.
9. Slip Canopy Loop Collar (F) over the chain, and
then do the same with the Canopy (G).
10. When ready to complete the installation, Use the
other chain connector and attach the other end of
the chain to the Canopy Loop (I) and close the chain
connector.
11. Feed the wires through Canopy Loop (J) and
Nipple (C) and pull until taut.
* You may now install the fixture.
12. Slide the Candle sleeves (R) on the sockets,
then hang the Crystals (S).
13. Place the Bottom cap (P) over the nipple at
fixture base and secure in place with the Finial (Q).
14. Install the light bulbs in accordance with the
fixture's specifications.
(DO NOT EXCEED THE MAXIMUM WATTAGE RATING)
Fig 2
For Customer Service, contact the place of purchase to arrange for replacement parts.

INSTALLATION INSTRUCTIONS
BARE COPPER
GREEN
(Ground)
FIXTURE WIRES
SMOOTH ( or BLACK)
RIBBED ( or WHITE)
BLACK
(Hot)
WHITE
(Netural)
HOUSE WIRES
G
CHAIN
J
H
F
E
D
JUNCTION BOX
(CEILING)
A
C
B
Fixture Name: Valencia 2049-4P/6/9/M1L FB
For Pendant Light Fixture
WARNING ! SHUT OFF POWER AT FUSE OR CIRCUIT BREAKER.
HANGING THE FIXTURE (Fig. 1)
1. Carefully remove the new fixtur e from the carton and
the yellow bag that holds all par t s. Check that all parts
are included as shown in t he illustrat ion and parts list.
2. Shut off the power at the circuit breaker and remove
old fixture from ceiling, including the old mounting strap.
3. Thread Nipple(C) into Canopy Loop (F) until snug.
4. Thread other end of the Nipple (C) with Canopy Loop
attached into Mounting Strap (D).
5. Place Lock Washer (B) over end of Nipple (C)
protruding through Mounting Strap (D) and thread Hex
Nuts (A) onto Nipple until tight.
6. Take this mounting strap assembly and mount to
ceiling junction box with Mounting screws (E). Tighten
screw securely with screw dr iver.
7. Unscrew the Canopy loop collar( H ) from the
Canopy loop. Take the canopy and pass over the
Canopy loop. approximately one half of the canopy loop
exterior threads should be exposed. Adjust until desired
height is reached. *the Canopy loop collar should fit
snugly on the Canopy loop after t he c anopy is installed.
Remove Canopy and Canopy lock collar.
8. Assemble the fixture and have an assistant or secure
support hold the weight of the fixture while you complete
the wiring connections.
9.Thread the fixture wires and ground wire of the
assembled fixture through the canopy loop and nipple
and into the outlet box.
CONNECTING THE WIRES (Fig 2)
10. Attach the power supply wires to the fixture
wires by connecting BLACK to BLACK (or SMOOTH)
and WHITE to WHITE (or RIBBED).
11. Attach the GROUND wire(GREEN or COPPER)
from the Junction Box and t he fixtur e Ground wire to the
green Ground Screw on t he M ount ing Bracket (D) or
connect both wires together using the correct size of
wire connectors.
NOTE: Twist the wires together in t he same direction
you twist the wire connector onto the wires.
12. Tuck these wire connections neatly into the
Junction Box.
FINISHING T HE INSTALLAT ION
13. Raise the Canopy (G) to t he ceiling. Secure in
place by tightening the Canopy Loop Collar (H) onto the
Canopy Loop (F).
Fig. 1
lead
YOUR INSTALLATION IS NOW COMPLETE.
RETURN POWER TO THE JUNCTION BOX AND
TEST THE FIXTURE.
For Customer Servic e, contact the place of purchase to arrange for re placement parts.