Reason why ( missing, scratched, broken glass, bent, bad finish)
For Customer Servic e, contact the place of purchase t o arrange f or replacement parts.
PARTS & ASSEMBLY SHEET
Read and review installation instruction sheet before
Company Name:_______________________Co. Account #:_____________
to be filled out by retailer
N
O
Bulb
(Not Provided)
M
Fixture Name: Madera 1821-6 BI
This fixture assembled PO:__________ Date: ________
Notice: Please review the parts listing and check for all parts before assembling the fixture. If any parts are missing or
damaged, please note on this sheet and contact the place of purchase to arrange for replacement parts.
PARTS LIST
Canopy Wire Connectors Top Loop
1ea @5-1/2"X1-1/2" 3ea P4 Orange 1ea 90 x 98mm
Chain
1ea 6ft x4.2mm 2ea 8/32" x 1" 1ea @15 x 2mm
Chain Connector Nipple
2ea @4.2X50mm 1ea @3/8 x 40mm x 5mm 1ea @3/8 x 50mm
Mounting Strap
w/ ground screw
Junction Box
Screw
Canopy Loop
with Collar
Hex Nut
Spring Washer
Decorative Chain
(support)
1ea 3/4"X4" 2ea @3/8 x 3mm 3ea
Part Needed Quantity
IXTURE ASSEMBLY INSTRUCTIONS
F
assembling the fixture.
Fig. 1
ASSEMBLING THE FIXTURE (Fig. 1)
1821-6 BI
1. Attach both ends of support chain (N) to the hooks of
Top loop (J) and hooks of fixture body (M) metal curl as
shown in the diagram.
2. Feed the fixture wires through the Top loop (J) and pull
the wires until taut.

PARTS & ASSEMBLY SHEET
Fixture Name:
ASSEMBLING THE FIXTURE (Fig. 2)
4. By measuring determine correct number of links
needed for proper hanging height. Use a pair of
pliers to open one link of the Chain (K) then remove
the excess Chain (K) and discard it.
5. Use one chain connector (L) to attach one end of
the chain to the Top loop (J) and close the chain
connector.
6. Feed the fixture wires thr ough the Chain (every
three links) and pull the wires until taut.
7. Slip Canopy loop collar (H) over the chain, then do the
7. Slip Canopy loop collar (H) over the chain,
same with the canopy (G).
then do the same with the canopy (G).
8. When ready to complete the installation Use the other
chain connector and attach the other end of the chain to
8. When ready to complete the installation Use the
the canopy loop (F) and close the chain connector.
other chain connector and attach the other end of
the chain to the canopy loop (F) and close the
9. Make sure the weight of the chandelier will be
chain connector.
supported by the chain-not the electrical wire.
* You may now install the fixture.
9. Make sure the weight of the chandelier will be
supported by the chain-not the electrical wire.
* You may now install the fixture.
Note: Complete these remaining steps after the
fixture is hung.
10. Install the light bulbs (not provided) in
accordance with the fixture's specifications.
(DO NOT EXCEED MAXIMUM WATTAGE RATING)
Madera 1821-6 BI
Fig. 2
For Customer Service, contact t he place of purchase to arrange for replacement parts.

For Customer Service, contact the place of purchase to arrange for replacement parts.
INSTALLATION INSTRUCTIONS
L
B
C
A
JUNCTION BOX
(CEILING)
D
E
F
H
CHAIN
G
BARE COPPER
(Ground)
GREEN
(Ground)
FIXTURE WIRES
SMOOTH (BLACK)
RIBBED (WHITE)
BLACK
WHITE
HOUSE WIRES
Fixture Name: Maderaa 1821-6 BI
For Chandelier Light Fixture
WARNING ! SHUT OFF POWER AT FUSE OR CIRCUIT BREAKER.
HANGING THE FIXTURE (Fig. 1)
1. Carefully remove the new fixtur e from the carton and the
yellow bag that holds all parts. Check that all parts ar e
included as shown in the illustration and parts list.
2. Shut off the power at the circuit breaker and rem ove old
fixture from ceiling, including the old mounting strap.
3. Thread Nipple(C) into Canopy Loop (F ) until snug.
4. Thread other end of the Nipple (C) with Canopy Loop
attached into Mounting Strap (D).
5. Place Lock Washer (B) over end of Nipple (C) protruding
through Mounting Strap (D) and thread Hex Nuts (A) onto
Nipple until tight.
6. Take this mounting strap assem bly and mount to ceiling
junction box with junction box Screws (E) . T ighten s c rew
securely with screw driver.
7. Unscrew the Canopy loop collar (H )from the Canopy loop.
Take the canopy and pass over the Canopy loop.
approximatly one half of the canopy loop exter ior thr eads
should be exposed. Adjust until desir ed height is r eached.
*the Canopy loop collar should fit snugly on the Canopy loop
after the canopy is installed. Remove Canopy and Canopy
lock collar.
8. Assemble the fixture and have an assis tant or sec ure
support hold the weight of the fixture while you complete the
wiring connections.
9. Thread the fixture wires and ground wire of the ass embled
fixture through the canopy loop and nipple and into the outlet
box.
CONNECTING THE WIRES (Fig. 2)
10. Attach the power supply wires to the fixture lead wires by
connecting BLACK to BLACK (or SMOOTH) and WHITE to
WHITE (or RIBBED).
11. Attach the GROUND wire(GREEN or COPPER) from the
Junction Box and the fixture Ground wire to the green G round
Screw on the Mounting Bracket (D) or connect both wires
together using the correct size of wire connectors.
NOTE: Twist the wires together in the same direction you
twist the wire connector onto the wires.
12. Tuck these wire connections neatly into the J unc tion Box.
13. Raise Canopy (G) to the ceiling and secure in place by
tightening the Canopy loop collar ( H) into the Canopy Loop
(F).
14. Install the light bulbs as per the fixture assem bly sheet.
Fig. 1
Fig. 2
YOUR INSTALLATIO N I S NOW CO MPLETE.
RETURN POWER TO THE JUNCTION BOX
AND TEST THE FIXTURE.