2ea @3/8 x 3mm 3ea @1/2" x 12"
Reason why ( missing, scratched, broken glass, bent, bad finish)
PARTS & ASSEMBLY SHEET
Read and review installation instruction sheet before
assembling the fixture.
This fixture assembled PO:__________ Date: ________
Company Name:_______________________Co. Account #:_____________
to be filled out by retailer
For Customer Service, contact the place of purchase to arrange for replacement parts.
Fixture Name: Pemberly Court 1089-M1L RSB-PRL
Notice: Please review the parts listing and check for all parts before assembling the fixture. If any parts are
missing or damaged, please note on this sheet and contact the place of purchase to arrange for
PARTS LIST
Canopy Wire connectors Top loop
1ea @5-1/2"X1-1/4" 3ea P3 Orange 1ea @3/8 x 45mm
Chain
1ea 1ft x4.2mm 2ea 8/32" x 1" 1ea @15 x 2mm
Chain connector Nipple
2ea @3X38mm 1ea @3/8 x 40mm x 5mm 1ea/3ea @3/8 x 65mm/@3/8 x 25mm
Mounting Strap
w/ ground screw
1ea 3/4"X4"
Part Needed Quantity
Junction Box
Screw
Canopy Loop
with Collar
Hex Nut Rod
Spring Washer
FIXTURE ASSEMBLY INSTRUCTIONS
1089-M1RSB
ASSEMBLING THE FIXTURE (Fig.1)
1. By measuring determine correct number of rods and chain
needed for proper hanging height. There are 2 ft of chain and
2 optional 12" rods included.
2. To shorten the fixture slide the excess 12" rods off the
wire.
3. To lengthen the fixture thread the additional rods onto the
wire or substitute longer chain for the 2 foot length included.
These two Rods
may be removed
or
additional Rods
may be added.
ROD-1089 RSB*
additional chain
may be added.
CHAIN-RSB *
*available for
purchase
separately

For Customer Service, contact the place of purchase to arrange for replacement parts.
ASSEMBLING THE FIXTURE (Fig.2)
Fixture Name: Pemberly Court 1089-M1RSB-PRL
4. Pull the fixture’s wire through the rods until taut.
5. Thread Rod (O) into Frame (M) until tight.
6. Thread additional Rods (O) together using Couplers (N)
between rods until tight. Repeat for any additional rods.
7. Feed the fixture wires through Top Loop (J) and pull the
wires until taut. Screw Top Loop (J) to the rod on the top of
8. Slip Canopy Loop Collar (H) over the chain, then do the
same with the Canopy (G).
9. When ready to complete the installation, use the other
chain connector and attach the other end of the chain to the
Canopy Loop (F). Then, close the chain connector.
10. Make sure the weight of the chandelier will be supported
by the chain-not the electrical wire.
* You may now install the fixture.
Note: Complete these remaining steps after the fixture is
hung.
11. Slide Glass Shade (P) over the socket of Frame (M) and
secure Glass Shade (P) by threading Socket Ring (Q) onto
the socket of Frame (M) until tight.
12. Install the light bulb (not provided) in accordance with the
fixture's specifications.
DO NOT EXCEED MAXIMUM WATTAGE RATING)

For Customer Service, contact the place of purchase to arrange for replacement parts.
HANGING THE FIXTURE (Fig.1)
junction box Screws (E). Tighten scr ew securely with screw driver.
CONNECTING THE WIRES (Fig 2)
BLACK to BLACK (or SMOOTH) and W H ITE to WHITE (or RIBBED).
13. Raise Canopy (G) t o the ceiling and sec ure in place by tighteni ng the
14. Install the light bulbs and glass shade as per the fi xture assembly sheet.
canopy loop and nipple and into the outlet box.
INSTALLATION INSTRUCTIONS
L
B
C
A
JUNCTION BOX
(CEILING)
D
E
F
H
J
CHAIN
G
BARE COPPER
(Ground)
GREEN
(Ground)
FIXTURE WIRES
SMOOTH (BLACK)
RIBBED (WHITE)
BLACK
WHITE
HOUSE WIRES
Fixture Name: Pemberly Court 1089-M1L RSB-PRL
WARNING ! SHUT OFF POWER AT FUSE OR CIRCUIT BREAKER.
1. Carefully remove the new fixture from the carton and the yellow bag that
holds all your part s. Check that all parts are included as shown in the
illustrations and the Parts and Assembly Sheet.
2. Shut off the power at the circuit breaker and remove old f ixture from ceiling,
including the old mount ing strap.
3. Thread Nipple (C) into Canopy Loop (F) until snug.
4. Thread other end of the Nipple (C) with Canopy Loop attached into Mounting
Strap (D).
5. Place Lock Washer (B) over end of Nipple (C) protruding through Mount ing
Strap (D) and thread Hex Nuts (A) onto Nipple until tight.
6. Take this mounting strap assembly and mount to ceiling junction box with
For Chandelier Light Fixture
7. Unscrew Canopy Loop Collar (H) from t he C anopy loop. Take the canopy
and pass over the Canopy loop. approximately one half of the canopy loop
exterior threads s hould be exposed. Adjust until desired height is reached. *the
Canopy loop collar should fit snugly on the Canopy loop after the canopy is
installed. Remove Canopy and C anopy lock collar .
8. Assemble the fixture and have an assist ant or secure support hold the weight
of the fixture while you complete the wiri ng connections.
9. Thread the fixture wi res and ground wire of t he assembled fixture t hrough the
10. Attach the power supply wires to t he fixture lead wires by connecting
11. Attach the GROUND w ire(GREEN or COPPER) from the Junct ion Box and
the fixture Ground wir e to the green Ground Screw on the Mounting Bracket (D)
or connect both wires together usi ng the correct s ize of wire connect ors.
NOTE: Twist the w ires together in the same direction you twist the wire
connector onto the wires.
12. Tuck these wi re connections neat ly into the Junction Box.
Canopy loop collar(H) into the Canopy Loop(F)
YOUR INSTALLATION IS NOW COMPLETE.
RETURN POWER TO THE JUNCTION BOX
AND TEST THE FIXTURE.