Golden Blount Alpine Linear Burner User Manual

INSTALLER! PLEASE LEAVE WITH HOMEOWNER
INST ALLATION AND OPERATING INSTRUCTIONS
Please Note: It is important that you read instructions before installing or operating this appliance
GENERAL INFORMATION
This appliance is to be burned only in an approved woodburning Fireplace with adequate chimney draft. When burning, the chimney damper must be FULLY OPEN. This appliance must be installed in a fireplace which operates properly when wood fires are burned.
For best results, natural gas pressure must be 7” to 10-1/2” water column.
If you smell gas:
1. Open Windows.
2. Don’t touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
If used with glass fireplace doors, burn with doors in open position.
Do not burn wood or other items with this appliance.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
FOR YOUR SAFETY
IMPORT ANT INFORMATION
CHECK TO BE SURE APPLIANCE IS FOR PROPER GAS TYPE.
This appliance is designed for use with Natural Gas unless clearly labeled for Propane (LP). Never use Propane Gas in an appliance designed for Natural Gas or Natural Gas in an appliance designed for use of Propane Gas.
The installation, including provisions for combustion and ventilation air, must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-1988 and NFPA54-1988.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system when testing at test pressures in excess of 1/2 psig.
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of gas-supply system at test pressures equal to or less than 1/2 psig. This is accomplished by closing the gas supply line valve, which is required by NFPA 54, section 5.54
The minimum inlet gas supply pressure for the purpose of input adjustment is 7” WC for Natural Gas and 11” WC for Propane Gas.
The maximum inlet gas supply pressure for this burner is 10.5” for Natural Gas and 13” for Propane Gas.
MANUFACTURED BY :
4301 WESTGROVE DRIVE
ADDISON, TX 75001
ALPINE LINEAR BURNER SPECIFICA TIONS
MODEL # MINIMUM FIREBOX BTU/HR
WIDTH AT 7” DEEP
FROM FRONT FIREBOX ALB24NAT 26” 22,500 ALB30NAT 32” 25,250 ALB36NAT 38” 34,000
ALB42NAT 44” 39,600 ALB48NAT 50” 44,352 ALB60NAT 62” 56,175 ALB72NAT 74” 68,000 ALB24LP 26” 20,500 ALB30LP 32” 31,000 ALB36LP 38” 37,750 ALB42LP 44” 43,800 ALB48LP 50” 49,000 ALB60LP 62” 62,250 ALB72LP 74” 75,500
COMPONENTS PARTS
ITEM
1. Alpine Linear Burner
2. Silica Sand
3. Vermiculite
4. Black Volcanic Cinders
5. Glowing Embers
6. Gas Connector
7. Damper Clamp
6”
6”
1
Width same as Model
Unit Dimensions
*The gas fittings supplied are for what the factory considers a normal installation. Some installations may require a longer connector tube or other fittings available in most hardware stores.