Gold Apollo AL-A26 Programming Manual

Page 1
Alpha-Numeric Display Pager
MODEL::AL-A26
Page 2
PAGER PROGRAMMING SOFTWARE
May 17, 2007 V1.0
ALA26
Contents
GETTING STARTED..................................................................................................................................................................1
E
QUIPMENT REQUIRED
-------------------------------------------------------------------------------------------------------------------------1
E
QUIPMENT SETUP
------------------------------------------------------------------------------------------------------------------------------1
INSTALLING PROGRAMMER SOFTWARE......................................................................................................................... 3
I
NSTALLATION
-----------------------------------------------------------------------------------------------------------------------------------3
R
UNNING
----------------------------------------------------------------------------------------------------------------------------------------- 7
ALA26 PROGRAMMING ..........................................................................................................................................................8
I
NTRODUCTION
----------------------------------------------------------------------------------------------------------------------------------8
S
TARTING THE PROGRAMMER
-----------------------------------------------------------------------------------------------------------------8
M
AIN MENU
----------------------------------------------------------------------------------------------------------------------------------- 10
M
ENU BAR
------------------------------------------------------------------------------------------------------------------------------------- 10
F
REQ. & CODES
------------------------------------------------------------------------------------------------------------------------------- 12
Frequency------------------------------------------------------------------------------------------------------------------------------ 12 Capcode (Decimal Address)--------------------------------------------------------------------------------------------------------- 13 Message Type Status------------------------------------------------------------------------------------------------------------------ 15 Auto Increase 1 after write ---------------------------------------------------------------------------------------------------------- 16
A
LERTS & STATUS
----------------------------------------------------------------------------------------------------------------------------- 17
Alerts and Status---------------------------------------------------------------------------------------------------------------------- 18 Manu Of Pager ----------------------------------------------------------------------------------------------------------------------- 21 Manual Write-------------------------------------------------------------------------------------------------------------------------- 22 Prompts -------------------------------------------------------------------------------------------------------------------------------- 22
P
ROMPTS EDIT
--------------------------------------------------------------------------------------------------------------------------------- 23
S
OURCE PROMPTS
----------------------------------------------------------------------------------------------------------------------------- 24
Page 3
PAGER PROGRAMMING SOFTWARE
Getting Started
May 17, 2007 1
ALA26
Getting Started
The ALA26 Pager Programming software, provides the flexibility to program ALA26 pagers to meet individual requirements. To obtain the best results from the product, please take a few minutes to read this instruction guide.
Equipment Required
To install and operate the programmer, you need a system that meets the following minimum requirements:
An personal computer (PC) with printer port, or compatible Windows 98 SE or above operating system (XP Recommended) 256 MB of RAM ALA26 Programmer An USB cable ALA26 Pager Programming Software
Equipment Setup
Refer to Figure 1 while performing the follows:
1. At the rear of the PC, connect the USB cable to the usb port on your computer.
2. Plug end of the USB cable into the ALA26 programmer.
3. Hardware installation is complete.
Page 4
PAGER PROGRAMMING SOFTWARE
Getting Started
May 17, 2007 2
ALA26
Figure
FigureFigure
Figure 1
1 1
1 Programmer Hardware Connections
Programmer Hardware Connections Programmer Hardware Connections
Programmer Hardware Connections
Page 5
PAGER PROGRAMMING SOFTWARE
Installing Programmer Software
May 17, 2007 3
ALA26
Installing Programmer Software
Installation
Install the programmer software into a PC as follows:
1. Uncompress the ALA26(USB)V505.zip and save them in a temporary directory.
2. Double click the setup.exe file. Click on “Y”.
3. Click “Next” on the Welcome screen.
Page 6
PAGER PROGRAMMING SOFTWARE
Installing Programmer Software
May 17, 2007 4
ALA26
4. Enter your user information and click “Next”. (Note: you must enter at least a single character "into the company field)
5. Choose where the program should be installed and click “Next”.
Page 7
PAGER PROGRAMMING SOFTWARE
Installing Programmer Software
May 17, 2007 5
ALA26
6. On the Select Program Folder screen choose where you would like the program to show up in your start menu and click “Install”.
Page 8
PAGER PROGRAMMING SOFTWARE
Installing Programmer Software
May 17, 2007 6
ALA26
7. If you had installed USB driver then select reboot now and click “Finish” on the setup complete screen.
8. If you did not install USB driver, click “OK” to install USB driver.
Page 9
PAGER PROGRAMMING SOFTWARE
Installing Programmer Software
May 17, 2007 7
ALA26
9. Please reboot your computer after USB driver and programming software installed.
Running
You now have the program installed. To run it from the Start menu/ Programs/ Gold Apollo /ALA26 Pager Programmer
Page 10
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 8
ALA26
ALA26 Programming
Introduction
Preparing a Pager for Reading or Programming:
1. Establish a computer hardware configuration.
2. Run the programming software of ALA26.
3. A Power LED illuminates on the Programming Interface to indicate proper contact. If the Power LED did not illuminate then you must check the configuration and restart the programming software of ALA26.
4. Align the pager contact pin holes with the contact pins of the ALA26 Programmer.
5. Press down on the pager until it is tight in the fixture.
6. Turn the pager off or wait the pager until standby mode. The pager is now ready to read or program.
Starting the Programmer
1. The application can be launched from Start Programs Gold Apollo ALA26 Pager Programmer. The following window appears:
2. Input your password. If key in wrong password for 3 times, the system shuts off automatically. If the password is correct, the following window appears:
Page 11
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 9
ALA26
3. Now, the system examines that the ALA26 programmer is well installed. If any questions, the following window appears:
4. Please re-check the ALA26 programmer and printer port are well installed or not. If connection succeeds with the ALA26 programmer, the system enters the Main Menu.
Page 12
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 10
ALA26
Main Menu
Menu bar
In the menu bar, there are main menus with submenus like those conventionally used in Windows applications.
G File | Open
Open the AL924 code-plug file. The file has the extension “.tbl”.
G File | Save
Save the current code-plug data to a file.
G File | Save As
Save the current code-plug data to a file with different filename.
G Pager | Write
Write the current code-plug data to the pager.
Page 13
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 11
ALA26
G Pager | Read
Read code-plug data from the pager.
G Pager | Verify
Verify the pager data.
G Help
Information about the AL26 pager programming version.
Page 14
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 12
ALA26
Freq. & Codes
Frequency
4 Range Of Frequency
You can select the range of frequency and all setting will load default value.
4 Frequency Of Pager
The frequency is on which the pager operates.
4 POCSAG Signal Baud Rate
The baud rate is on which the pager operates.
Page 15
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 13
ALA26
Capcode (Decimal Address)
4 Cap #1
Please input 1st Capcode (7 Dec digits between 8 and 2097151).
ON
Enable or disable 2nd Capcode (address).
4 Fun. Bit
Click to set function bit(ABCD) message control.
Page 16
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 14
ALA26
ִ Disable & Disp.
Function Bit(ABCD) Message Display:
N: STD Number.
P: PRC Number.
A: Alpha number.
I: Ideographic.
T: Tone only
D: Disable
ִ Priority
Function Bit(ABCD) Priority Alert: V is Enable, - is disable.
ִ Type
Function Bit(ABCD) Message Type:
P: Personal.  1 to 9: Mail Drop 1 to Mail Drop 9.  A to E: Mail Drop A to Mail Drop E.  G: Group.
Page 17
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 15
ALA26
Message Type Status
4 Alert Length Select
Click to set personal and mail drop(1~9A~E) alert length.
Page 18
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 16
ALA26
ִ Personal and Group Alert Length
The available selections for all personal and group call messages alerts are:
02: 2 sec.
08: 8 sec.
16: 16 sec.
32: 32 sec.
CT: continuous.
ִ Mail Drop Alert Length
The available selections for mail drop messages alerts are:
--: Disable.
BP: Short Beep.
01: 1 sec.
16: 16 sec.
Auto Increase 1 after write
1st Capcode Auto Increase
1st capcode always increment by one after write.
2nd Capcode Auto Increase
2nd capcode always increment by one after write.
Page 19
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 17
ALA26
Alerts & Status
Page 20
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 18
ALA26
Alerts and Status
Duplicate Msg. Detect
If it is selected, duplication detection is performed on all personal messages with the same message type as the new message, on a character by character basis. Error characters are ignored during the check. If all non-error characters in both messages match, the existing matching message is flagged as a duplicate. The message with the least number of errors is stored and the other messages are discarded. Duplication is not performed on mail-drop messages.
Discard Error Msg.
If it is selected, error message will be discarded.
Disp. Source Addr. ON
If it is selected, the message will show the address source at last.
4 Battery Gauge Level-High
This value represents the battery voltage level necessary for the battery gauge to display a full battery. If the battery voltage is higher or equal to this value, the full battery gauge icon is displayed. Valid selections are: 1.58V, 1.53V, 1.48V, 1.43V,
1.39V, 1.35V, 1.29V, 1.23V, 1.19V, 1.14V, 1.09V, 1.05V, and 1.00V. The High level must be greater than the Med level, and the Med level Must be greater than the Low level. None of the levels can be equal to each other.
Page 21
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 19
ALA26
4 Battery Gauge Level-Med
This value represents the battery voltage level necessary for the battery gauge to display a full battery. If the battery voltage is higher or equal to this value, the full battery gauge icon is displayed. Valid selections are: 1.58V, 1.53V, 1.48V, 1.43V,
1.39V, 1.35V, 1.29V, 1.23V, 1.19V, 1.14V, 1.09V, 1.05V, and 1.00V. The High level must be greater than the Med level, and the Med level Must be greater than the Low level. None of the levels can be equal to each other.
4 Battery Gauge Level-Low
This value represents the battery voltage level necessary for the battery gauge to display a full battery. If the battery voltage is higher or equal to this value, the full battery gauge icon is displayed. Valid selections are: 1.58V, 1.53V, 1.48V, 1.43V,
1.39V, 1.35V, 1.29V, 1.23V, 1.19V, 1.14V, 1.09V, 1.05V, and 1.00V. The High level must be greater than the Med level, and the Med level Must be greater than the Low level. None of the levels can be equal to each other.
Push Key Lamp On Enable
If it is selected, the back-light will turn on after any key be pressed.
RD Key Delete Enable
If it is selected, the RD key can use as delete feature at read message moment.
RD Key Pager Off
If it is selected, the RD key can use as Pager off feature at time display moment.
Long Message Control Enable.
If it is selected, then the message most length is 2,000 characters, otherwise the length only can be 300 characters.
Beep And Vibration
If it is selected, beep and vibration will active together.
4 Paging Display
If “Direct” is selected then the message will show on the display at a message received. Otherwise it only shows a message location icon on the display.
Direct Show Lamp On
When the paging display is “Direct”, if it is selected, the back-light will turn on at a message received.
Page 22
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 20
ALA26
Lowcell Alert ON
If it is selected, the pager emits a, low battery cell alert when the battery reaches a low cell state.
4 Polarity
It select the RF signal polarity is normal or invert.
4 Sequential Lockout
The value is a sequential lockout timer begins when a message arrives and is flagged as being sequentially locked out. If duplicate messages arrive, one of the messages is disregarded and not flagged as a duplicate. Valid selections are disabled, 30 seconds, 60 seconds, 120 seconds, 175 seconds and 240 seconds.
4 Reminder Duration
With this option selected, the time period begins with a newly arrived message and is reset every time a new message is received. Once the time period expires, the pager does not emit any more reminder alerts until a new message arrives. Valid time period selections are: Disable, 2 minutes, 10 minutes and 60 minutes.
4 Out-of Service Control
With an out-of-service time specified by the code plug, the pager is considered “out of service” when it does not detect a POCSAG synchronization word for that time period. The out-of-service icon displays at this time. Valid selections are: disabled, 1 min, 2 min, 5 min and 10 min.
4 Read Time Out
The current pager display changes after the selected time frame has expired. Valid selections are: 8 sec, 12 sec, 20 sec, 30 sec.
4 Password (4 Dec)
It is used for the user’s manual programming.
4 Screen Contrast
It selects the LCD display contract level.
Counter Out Enable
If it is selected, the message will indicate the counter number at first.
Page 23
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 21
ALA26
Manu Of Pager
Zoom In/Out Disable
If it is selected, menu of zoom function will be disabled.
Set Scroll Disable
If it is selected, menu of scroll is disabled.
Set Time Disable
If it is selected, menu of set time is disabled.
Set Alarm Disable
If it is selected, menu of set alarm is disabled.
Set Alert Disable
If it is selected, menu of set alert is disabled then you must select one of 5 type alerts as your default.
Power Off Disable
If it is selected, menu of pager off is disabled.
Auto Sleep Disable
If it is selected, menu of auto sleep is disabled.
Page 24
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 22
ALA26
Manual Write
Manual Write Enable
If it is selected, manual write enable.
Frequency Modification Enable
If it is selected, frequency modification is enabled at manual programming.
Password Required Enable
If it is selected, enters manual programming password is required.
Password Modification Enable
If it is selected, enters manual programming password can be modification.
Prompts
Page 25
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 23
ALA26
Prompts Edit
Each prompt can be customized in the code-lug, if desired, or the defaults can be used.
Page 26
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 24
ALA26
Source Prompts
Page 27
PAGER PROGRAMMING SOFTWARE
ALA26 Programming
May 17, 2007 25
ALA26
4 Prompt Control
Each prompt can be customized in the code-lug, if desired, or the defaults can be used. If selected, the text programmed is displayed at the first of the message or end of message.