Godox K-150A, K-180A Instruction Manual

Page 1
Mini Master Series Studio Strobe
K-150A/K-180A
小霸王闪光灯
Instruction Manual
使用说明书
705-K180A0-00
Made In China
地址/Add: 深圳市宝安区福永镇福洲大道西新和村华发工业园A4栋 Building A4, Xinhe Huafa Industrial Zone, Fuzhou RD West, Fuyong Town, Baoan District, Shenzhen 518103, China 电话/Tel: +86-755-29609320(8062) 传真/Fax: +86-755-25723423 邮箱/E-mail: godox@godox.com http://www.godox.com
深圳市神牛摄影器材有限公司
GODOX Photo Equipment Co., Ltd.
Page 2
07 Foreword
08 Warning
08 Caution
09 Names of Parts
09
Body
09
Accessories
10 Instructions for Use
10
Flash Preparation
10
Power Connection
10
Modeling Lamp
10
Flash Output Control
10
Test Button
10
Sync Triggering
11
Slave Trigger Model
11
Tube Replacement
11 Technical Data
12 Maintenance
Contents
Foreword
Thank you for purchasing Mini Master Series Studio Strobe. This device is designed for photographers seeking a high quality studio equipment at an affordable price. With its well-chosen key components and parts, the product is of high quality, stability and reliability for all portrait, fashion, wedding art, advertisement photography and video shooting etc.
87
To prevent damage to the product or injury to you or to others, read the following warnings in their entirety before using this product. Keep these Warning where users can read them for ready reference.
Do not disassemble or modify. Should the product break down, send the defective back to the authorized service center for inspection and
maintenance.
Keep dry. Do not handle with wet hands, immerse in water, or expose to rain.
Keep out of reach of children.
Please put the device in a ventilation environment and keep the parts of lighting and heat dissipation holes are unobstructed. Do not use in flammable environment.
As this product adopts make and break device, please keep it easy to be used.
No touching the heating parts of this product.
Please turn off the power and wear insulated gloves before installing and connecting accessories. When replacing the tube or modeling lamp, please make sure that the tube is cool and wear insulated gloves to prevent burns.
Do not flash directly towards naked eyes (especially those of babies), otherwise it may lead to visual impairment.
Disconnect from the power supply when it will not be used for an extended period.
Warning
Caution
After 30 continuous flashes at full power, the flash should be cooled down for
about 3 minutes. Overheating will occur if it is used continuously without cooling
down.
Do not keep using the modeling lamp for a long time; otherwise flammable
accessories attaching to flash head, e.g. softbox will get burnt. A 10-minute time
is recommended in this case. After 10 minutes, cool it down for 1 minute.
When using a snoot, do not keep the modeling lamp on for a long time or fire
too frequently (not over six times for one minute). Overheating will result in
damages for strobe housing and/or studio light.
Avoid sudden impacts as this can damage the flash tube and/or modeling lamp.
Page 3
109
(1) Power Socket (2) Fuse (3) Power Switch (4) Test Button (5) Flash Output Controller (6) Light Sensor (7) Charging LED Indicator (8) Modeling Light Switch (9) Sync Cord Jack (10)Mounting Bracket (11)Umbrella Input
1
2
3
4
5 6 7
8
9
11
10
Instructions for Use
Power Connection
Use the power cord to connect the flash to an AC power source and turn on the power switch (3). The charging indicator lamp (7) is off when it is charging, no flash at this moment. The unit is ready to fire until the charging indicator lamp (7) is on, meaning it is fully charged. Set the power switch on O position when it is not in use.
Modeling lamp
Modeling lamp switch (8) decides whether the modeling lamp is on or off: Downwards (O position), it’s off; upwards (I position), it’s on. (NOTE: Do not keep long time in using the modeling lamp. It’s better to be cooled down for 1 minute after 5 minutes continuous use.)
Flash Output Control
Flash output controller (5) controls the power radio, adjustable stepless power from 1/8 to full. It can satisfy the light requirements in different environment. (Note: When adjusting the power from full power to a lower setting, press the test button to release the power in the capacitor, so when recharged, the flash output will be in the corresponding setting.)
Test Button
To fire the flash without taking a picture, push the test button. It can also adjust the brightness when combined with the flash output controller (5).
Sync Triggering
A sync cord (9) is provided with your flash unit, and the input is a Φ
3.5mm mini plug. Insert a trigger plug here and the flash will be fired synchronously.
Flash Preparation
Mount the flash unit on an appropriate light stand and adjust the mounting bracket (10). Make sure it’s tightened and fixed. The umbrella input (11) is applicable for any studio umbrella.
Names of Parts
Accessories
Body
Modeling Lamp Power Cord
Instruction Manual
Page 4
1211
Technical Data
Slave Trigger Model
The flash will be fired synchronously with one external flash. This model can act as an auxiliary lamp, offering various effects of light and shadow.
Tube Replacement
Turn down the power before replacing the flash tube and wear insulated gloves. Then, loosen the iron wire on the tube, keep a balanced hold on the two feet of the flash tube and pull out the old tube gently. Take down the feet casing to put it on the new one. Hold two feet of the new tube, and target directly towards the two copper outlets, then push them slightly in. Tighten the iron wire to fix the flash tube.
Model
K-150A
K-180A
Flash Output 150WS 180WS Guide Number (m ISO 100) 42 45 Color Temperature 5600±200K Power Voltage
AC220/60Hz or 100V/60Hz
Flash Power Control stepless Modeling Lamp
75WS
Recharging Time 0.5 -3 sec Flash Triggering Method Sync cord, Test button, Slave Flash Duration 1/2000-1/800s Fuse 5A Dimension 190*150*105mm Weight Approx 0.59KG
Shut down the device immediately when it works abnormally and
find out the reason.
Avoid sudden impacts and the lamp should be dedusted usually.
It’s normal for lamp being warm when in use. Avoid continuous flashes
when it is not necessary.
Maintenance of all the flashes is up to our authorized maintenance
department which can provide original accessories.
One year warranty period will be canceled when any unauthorized
maintenance is found.
If the product had failures or is wetted, it can be continuously used only
after it is repaired by professionals.
Disconnect the power when doing maintenance work or cleaning.
New changes made to the specification may not be updated in this
manual.