GN Resound 6060-DI, 4060-VI, Danalogic 6 6060-DI, Danalogic 6 4060-VI User Manual

USER GUIDE
Danalogic 6 BTE 6060-DI 4060-VI
DANALOGIC 6 MINI BEHIND-THE-EAR PERSONAL HEARING SYSTEM
Congratulations with your new fully-digital GN ReSound hearing instrument!
This booklet describes the functionality of all mini-BTE (Behind-The-Ear) models in the Danalogic 6 product line. The functionality depends on the model; your hearing care professional will highlight the features of your particular hearing instrument.
GN ReSound’s advanced technology and customized programmes, selected by your hearing care profes­sional, will bring the best possible hearing solution to your family life, and your professional and social activ­ities.
Your hearing instrument has been adjusted to your individual hearing loss. Please familiarize yourself with the information in this booklet. Proper understanding and use of your new GN ReSound hearing instrument will allow you to derive maximum hearing benefit.
This instruction covers the following Danalogic 6 mini BTE products: 6060-DI and 4060-VI.
Danalogic 6 is a trademark of GN ReSound.
2
Contents page
Your Danalogic 6 mini Hearing Instrument 4
Programme Selector 8
Your Programme Environments 8
Directionality 9
Stand-by Function 9
On/Off Function 10
SmartStart 10
Volume Control 11
Direct Audio Input (DAI) 12
Inserting and removing the Instrument 13
Low Battery Warning 15
Changing the Battery 15
Battery Warning Information 16
Daily Maintenance 17
Cleaning the Ear Mould and replacing Sound Outlet Filter 18
Cleaning the Thin Tube and Dome 20
The Domes 21
How to mount the Tulip-Dome 21
Telephone Use 23
Using Assistive Listening Systems 24
Repairs 24
Troubleshooting Guide 26
General Precautions 28
Technical Data 29
Key Word Index 30
3
4
Your Danalogic 6 mini Hearing Instrument
1. Programme Selector
2. Battery Compartment & On/Off Switch
3. Sound Outlet
4. 1
st
Microphone Sound Inlet
5. 2
nd
Microphone Sound Inlet (6060-DI)
6. Volume Control (4060-VI)
2
3
4
1
5
6060-DI
2
3
4
1
6
4060-VI
5
8. Left/Right indicator (Right=Red, Left=Blue)
9. Battery lock
10. Model
11. Manufacturer
9
10
8
11
6060-DI
6
Your Danalogic 6 mini Thin Tube Hearing Instrument
1. Programme Selector
2. Battery Compartment & On/Off Switch
3. Thin Tube Adaptor
4. 1st Microphone Sound Inlet
5. 2nd Microphone Sound inlet (6060-DI)
6. Thin Tube with standard dome
7. Volume Control (4060-VI)
4
2
1
3
6
5
4
2
1
3
6
7
6060-DI
4060-VI
7
8. Left/Right indicator (Right=Red, Left=Blue)
9. Battery lock
10. Model
11. Manufacturer
9
10
8
6060-DI
11
8
Programme Selector
Your hearing care professional has most likely programmed multiple programmes into your instrument. You can select programmes simply by depressing the programme selector once. You will then hear one or more “beeps”, indicating which programme you have selected. Your hearing instru­ment will switch programmes as follows:
Examples: 3 programmes: 1
2, 2 3, 3 1
With optional telecoil: 1
2, 2 3, 3 T, T → 1
With Direct Audio Input: 1
2, 2 3, 3 DAI, DAI 1
You can always return to programme 1 by turning your instrument off and then on again or by placing it in stand­by mode and then returning to its operating mode.
Your Programme Environments
Programme Description of when to use
9
Telecoil
See section “Telephone Use” for a detailed description of this function. ReSound Danalogic 6 BTE instruments are all equipped with a telecoil in their standard version.
Directionality
ReSound Danalogic 6 6060-DI mini is equipped with two microphones and thus offers directionality. That is a function which enables better speech understanding in noisy situations. This function focuses on speech in front of you while sounds coming from the back or the side are sup­pressed. Directionality is available as an option in the custom programmes. Please ask your hearing care professional about this feature.
Stand-by Function
To put the instrument into stand-by mode, hold down the programme selector for 5 seconds. You will hear a series of beeps, and the device is now in stand-by mode. Before returning to functional mode, you will need to wait approx­imately 5 seconds. After waiting, press the programme selector down once. Please note that the instrument is using a small amount of power when it is in stand-by mode.
10
On/Off Function
ReSound Danalogic 6 mini is equipped with an on/off switch integrated into the battery compartment. When the battery compartment is fully closed, the instrument is turned on in its functional mode and programme 1 will be activated. Partially open the battery door until it snaps into the off­position. The instrument is then switched off. Whenever you are not wearing the instrument, remember to turn it off to reduce battery consumption.
SmartStart
SmartStart allows you to put the instrument on the ear with­out annoying sounds like squealing. It delays the switch on time 10 seconds after closing the battery compartment, and is indicated by a beep every second after closing the battery compartment. This function can be activated or deactivated by your hearing care professional.
Loading...
+ 22 hidden pages