Gnatus Water Unit Syncrus G1 User manual

PRESENTATION OF MANUAL
INSTRUCTIONS FOR USE
Technical Name: Odontological cuspidor
Brand: Gnatus
Trade Name: Water Unit Syncrus G1
Manufacturer / Distribuitor:
GNATUS - EQUIPAMENTOS MÉDICO-ODONTOLÓGICOS LTDA. Rod. Abrão Assed , Km 53+450m - Cx. Postal 782 CEP 14097-500 Ribeirão Preto - S.P. - Brasil Fone +55 (16) 2102-5000 - Fax +55 (16) 2102-5001 C.N.P.J. 48.015.119/0001-64 - Insc. Est. 582.329.957.115 www.gnatus.com.br - gnatus@gnatus.com.br Technical Duties: Gilberto Henrique Canesin Nomelini CREA-SP: 0600891412
Registration ANVISA nº: 10229030062
ATTENTION
For greater safety:
Read and understand all the instructions contained in these
Instructions for Use before installing or operating this Equipment.
Note: These Instructions for Use must be read by all the operators
of this Equipment.
2
INDEX
PRESENTATION OF MANUAL .......................................................................... 02
IDENTIFICATION OF EQUIPMENT ................................................................... 04
- Indication of Equipment .................................................................................. 04
- Principles and fundamentals applied to the product functioning .............................. 04
- Equipment Description ..................................................................................... 05
MODULES, ACCESSORIES, OPTIONALS AND CONSUMPTION MATERIALS ......... 07
TECHNICAL SPECIFICATIONS ......................................................................... 11
- Technical features of the Unit and its accessories ................................................. 11
- Standards applied ........................................................................................... 12
- Electromagnetic emissions ................................................................................ 13
- Dimensions .................................................................................................... 16
- Packing symbols ............................................................................................. 17
- Product symbols ............................................................................................. 17
- Content of accessible and non-accessible demarcations ....................................... 18
INSTALLATION OF EQUIPMENT ...................................................................... 18
OPERATION OF EQUIPMENT ........................................................................... 19
PRECAUTIONS, RESTRICTIONS AND WARNINGS ............................................ 23
- Transportation, storage and operation ................................................................ 23
- Sensitivity to environmental conditions in normal situations of use ......................... 23
- Precautions and warnings “during the installation” of equipment ............................ 23
- Recommendations for the dental equipment maintenance. .................................... 24
- Precautions and warnings “during the use” of equipment ...................................... 24
- Precautions and warnings “after” the use of equipment ........................................ 24
- Precautions and warnings during the “cleaning and disinfection” of equipment ......... 25
- Precautions in case of alteration in the functioning of equipment ............................ 25
- Precautions to be adopted against foreseeable or uncommon risks,
related to the deactivation and abandoning of equipment ........................................ 25
CORRECTIVE AND PREVENTIVE MAINTENANCE AND PRESERVATION.............. 26
- Additional procedures for reuse ......................................................................... 26
- Cleaning ........................................................................................................ 26
- Disinfection .................................................................................................... 26
- Preventive maintenance ................................................................................... 29
- Corrective maintenance.................................................................................... 29
UNFORESEEN EVENTS – SOLUTION OF PROBLEMS .......................................... 30
EQUIPMENT’S WARRANTY .............................................................................. 32
FINAL CONSIDERATIONS ................................................................................ 32
33
IDENTIFICATION OF EQUIPMENT
Dear Customer
Congratulations. You have made a good choice when you decided to buy a GNATUS QUALITY product comparable to the best products available in the World. This manual is a general presentation of your product and it will give you important details to help you to solve possible problems.
Please, read it and keep this with you.
Indication of Equipment
This equipment is for dental use use only. It must be operated and utilized by specialized
professional (certied professional, according to the legislation of the country) and following
the instructions of the manual. The operation of the equipment required, for the professional, the utilization of correct instruments and it should to be in perfect conditions of the use, and to protect the professional, the patients and others, in the eventual danger situation.
Principles and fundamentals applied to the product functioning
Auxiliary waste collector unit, has suctors which suction is caused by venturi system or vacuum pump with compressed air.
Identication
Technical Name: Odontological cuspidor
Brand: Gnatus
Trade Name: Water Unit Syncrus G1
4
IDENTIFICATION OF EQUIPMENT
Equipment Description
Water unit for dental purposes and for auxiliary tasks such as water supply for waste collection and activation of the spittoon and the dental suction unit; ambidextrous (serves right-handed and left-handed); coupled to the chair.
Housing structure built in Steel with the body coated in high-impact polystyrene and UV
protection. High-brightness epoxy-based at painting, polymerized in an oven at 250ºC,
phosphate treated and corrosion and cleaning products resistant.
*It has 90º moving, prioritizing ergonomy and allowing the auxiliary approximation.
Ceramic spittoon cube; deep and easy-to-remove for hygiene and asepsis, comes with drain for solid retention.
Plain, rounded, light and exible hoses, without grooves and with a quick tting that
easily connects without the necessity for tools.
Water conductors that wash the cube and cup holder corrosion resistant.
With waste lter making cleaning and disinfection easier.
Activating record and water regulation in the cube and *coaster.
*Electric controls for activating the water in the cube, coaster, Bio-System and water heating at the triple syringe.
Suction units with easy-to-use individual triggering that allows an excellent operational performance; a better visualization of the operatory field to the professional with contamination risk reducing by the aerosol and for higher comfort to the patient.
*High power suction units with electric low voltage individual activating, allows smoothness and precision on the activation.
*Triple syringe with a removable and autoclavable rotary nozzle.
*Reaching arm: terminal support with wide horizontal moving that allows an ideal
approximation to the operatory eld and great accessibility to the available resources.
Optimizes the work prioritizing ergonomy and biosafety.
EN ISO 9001/2000 and EN ISO 13485/2003 Quality System, assuryng the products are manufactured under standart procedures.
Products manufactured in agreement with RDC 59/00 - ANVISA - (Sanitary Surveillance National Agency).
*Curing Light
Product Features:
Designed to carry out curing resin material through a curing process. The wavelength
of 440nm - 460nm associated with high energy emitted by Curing Light enables the multifunctionality of this device.
It has high power LED with efcient coupling and optical distribution, providing speed
and security procedures. Ensures proper photo-activation of materials without wasting light.
The LED system of this machine has long service life, equivalent to 36 million 10-second
cycles without loss of power and efciency in the photo activation.
The reduced weight of the pen and its anatomical design ensure a more comfortable and practical professional work.
Operation control with display and buttons on the pen itself.
Programmable operating time.
- 10, 20, 40, 60, 80 and 90 seconds with sound signal (beep) every 10 seconds.
- Shows the elapsed time and the end of the operation.
- No special optical lters.
- Low power consumption.
* Optional item
55
IDENTIFICATION OF EQUIPMENT
- Low cost of replacement.
The cold light does not emit heat as conventional bulbs - Low temperature light polymerizes the resin without damaging the tooth pulp and prevents thermal expansion problems.
- The forced ventilation system, transmitting unpleasant noise is not necessary.
- High strength piece
Conductive light removable tip, made of high strength polymer and easy maintenance
- Suitable for single bleaching or up to three teeth.
Swivel eye protection - Ensures full protection without compromising the visual eld.
*Bicarbonate jet SET/ Hand Jet
Product Features:
See Owner's Manual – Hand jet
* Optional item
6
MODULES, ACCESSORIES, OPTIONALS AND CONSUMP TION MATERIALS
The content on this page is informative; the equipment can be different from those illustrated. Therefore, when purchasing the product check the technical compatibility between equipment, coupling and accessories.
04
06
03
07
B
02
01
A
10
11
12 13
09
0805
A
A
16
B
14
15
01 - Water conductor cup holder
* *
02 - Water conductor bowl 03 - Bowl 04 - Drain 05 - Triple syringe
*
06 - Venturi type suctor
*
07 - Vacuum pump suctor
*
08 - Driving to the water in the bowl
*
09 - Water cupller activation
*
* Optional item
10 - Cupller 11 - Bowl ush adjustment 12 - Sucker lter
*
13 - Cupller ush adjustment
*
14 - Air output
*
15 - Water output
*
16 - Bio System
*
* Items 08 and 09 with programmable timer for water triggering in the cube and in the coaster for
an interval previously dened by the professional.
77
MODULES, ACCESSORIES, OPTIONALS AND CONSUMP TION MATERIALS
01
04
10
02
05 06
0807 09
11
03
12
13 14 15
8
MODULES, ACCESSORIES, OPTIONALS AND CONSUMP TION MATERIALS
01.Terminals:
*
16
17
The drawing illustrates all optional items (page 08 and 09). Therefore, your equipment will consist only of the chosen items selected during your purchase option.
The use of any part, accessory or material
not specied or provided
in these instructions is of entire responsibility of the user.
TB: Borden terminal TM: Midwest terminal
FO: Optical ber Terminal
MME: Electric microengine Terminal
02.Curing light + tip for 3 teeth
*
03.Water triggering pedal for the bowl or cup
*
holder.
04.Bicarbonate jet kit “Jet Hand”
*
05.Arm reach coupling with capacity for 5 tips
* *
06. Arm reach coupling with capacity for 3 tips
07. Seringa tríplice com corpo totalmente metálico
*
ou com manopla injetada em termoplástico "Kit aquecedor opcional"
08. Triple syringe with a fully metallic body or
*
with an injected handle in thermoplastic "Optional heater Kit"
09.Aspirators:
*
Venturi type aspirator Bigger Aspirator for Vacuum Pump Smaller Aspirator for Vacuum Pump Aspirator cleaning brush Aspiration cannula
Obs: Suction units available with fully metallic cups
*
10. Bio-System triggering
*
11.Water selection valve - reservoir/network
*
12.Master valve (System that allows the cutting of
*
the water and air ow to the ofce.)
13.Arm reach coupling with capacity for 2 tips
*
14. Water conductors that wash the cube and
*
the Stainless Steel coaster, removable and autoclavable.
15.Cube made of injected material
*
16.Lid the drain
*
17. Bigger lter
*
99
MODULES, ACCESSORIES, OPTIONALS AND CONSUMP TION MATERIALS
Units may be made composed by:
Optional Acronyms
1 BV sucker 1 Venturi sucker
1 Venturi sucker + 1 BV sucker 2 Venturi suckers 2 BV suckers 1 Syringe + 1 Venturi sucker 1 Syringe + 1 BV sucker 1 Syringe + 1 Venturi sucker +1 BV sucker 1 Syringe + 2 Venturi sucker 1 Syringe + 2 BV sucker 1 Syringe + 1 Photo +1 Terminal High Speed + 1 Terminal micro motor +
1 Venturi sucker 1 Syringe + 1 Photo + 1 Terminal High Speed + Terminal micro motor
+ 1 BV sucker Curing Light Cup holder Intra Oral Camera Arm reach Complete equipment
TBV TV
2T 2 TV 2T BV S TV S TBV 3T 3T V 3T BV 5T
5T BV
OPTI E CAM ALC FULL
Identication label "responsible eld to identify the product conguration."
10
TECHNICAL SPECIFICATIONS
Technical features of the Unit and its accessories General
Classication of Equipment as per ANVISA:
Class II
Classication of Equipment as per standard IEC 60601-1:
Protection against Electric Shock - Type B and Class I Equipment (IEC 60601-1)
Power Supply
Inlet air pressure 60 - 80 PSI ±2 Voltage in equipment (coming from dental chair) 12V~ and 24 V~
Other specications
Net weight (complete version) 3 Kg Gross weight (complete version) 3,5 Kg Venturi suction system – Maximum vacuum
220 mm/Hg
Venturi suction system – Volumetric displacement 30 l/min
Specications of Curring Light
Power 5,2VA Light source 1 LED Active medium Semicondutor Led (InGaN) Wavelength 440nm - 460nm Timer 90 seconds
1111
Loading...