UNFORESEEN EVENTS – SOLUTION OF PROBLEMS ........................................30
WARRANTY OF EQUIPMENT ..........................................................................31
FINAL CONSIDERATIONS ..............................................................................31
33
DESCRIPTION OF THE EQUIPMENT
Dear Customer
Congratulations. You have made a good choice when you decided to buy a GNATUS
QUALITY product comparable to the best products available in the World. This manual is a
general presentation of your product and it will give you important details to help you to
solve possible problems.
Please, read it and keep this with you.
Identication
Technical Name: Odontological cuspidor
Brand: Gnatus
Trade Name: Syncrus L - POP Water Unit
4
DESCRIPTION OF THE EQUIPMENT
Principles and bases applied to the functioning of the product
Unit for auxiliary work as water supply for waste collection and activation of spitting
bowls and aspirator, It has ejectors, with suction activated by a venturi system or vacuum
pump with compressed air.
Description of Equipment
Water unit for dental use, for auxiliary work such as supply water for collecting waste
and activating the rinsing bowl and saliva ejectors; ambidextrous (serves both right-handers
and left-handers), couple to the dental chair.
Activation stopcock and adjustment of the water in the bowl. Electrical controls for the
outow of the water in the cup ller (available in the Water Unit model Syncrus L E TV, LE
2T and L E 2 TV).
Removable round rinsing bowl, with a diameter of 220mm, provides perfect disinfection.
Body of the unit made of steel and coated with high impact polystyrene.
Structure of the unit made of steel, with glossy smooth paint with a base of epoxy,
polymerized in an oven at 250ºC, with a phosphatized treatment resistant to corrosion and
cleaning materials, a structure coated with high impact polystyrene with rounded edges.
Flexible, light rounded hoses and quick coupling which connect and disconnect easily
without requiring tools.
Water conduits which wash the non-autoclavable bowl and cup ller. Strainer to retain
solids.
Saliva ejector with automatic activation easy to use, which provides an excellent
operational performance, allowing the professional to see operational eld better with a
reduced risk of contamination from aerosol and greater comfort for the patient.
High power ejectors with electrical activation of a low individual voltage, providing
lightness and accuracy upon activation (available in the Syncrus L 2T and L E 2T Water Units).
ISO 9001/2000 and ISO 13485/2003 Quality System, assuryng the products are
manufactured under standart procedures. Products manufactured in agreement with RDC-
59 - ANVISA (Sanitary Surveillance National Agency) with guarantees accomplishiment
to the sanitary legislation according to BPF (Good Manufacturing Procedures). In order to
comply with directive 93/42/EEC for CE Mark purpose, it is dened that the life span of this
product is estimated in 05 years provided that the enduser follows the requirements and
instructions of this manual.
IMPORTANT:
• This equipment is for dental use use only. It must be operated and utilized by specialized
professional (certied professional, according to the legislation of the country) and following
the instructions of the manual. The operation of the equipment required, for the professional,
the utilization of correct instruments and it should to be in perfect conditions of the use,
and to protect the professional, the patients and others, in the eventual danger situation.
• This equipment can’t be used in the presence of inammable anesthetics or products
that may cause explosion.
• After nish life-cycle of the equipment, this equipment is throw way, so it should to be
destroyed in appropriate area (according to the legislation of the country).
•To guarantee the safe functioning of your equipment, use only the assemble
congurations (Dental Chair, Dental and Water Units and Dental Light) supplied by Gnatus
authorized Dealers / Technical Assistance.
55
DESCRIPTION OF THE EQUIPMENT
The Water Units are composed according to list below:
Water Units Syncrus L TV
- 1 Ejector type Venturi
Water Unit Syncrus L E TV
- 1 Ejector type Venturi
Water Units Syncrus L 2 T
- 1 Ejector type Venturi
- 1 Ejector for Vacuum Pump
Water Unit Syncrus L E 2 T
- 1 Ejector type Venturi
- 1 Ejector for Vacuum Pump
Water Units Syncrus L 2 TV
- 2 Ejectors for Vacuum Pump
Water Unit Syncrus L E 2 TV
- 2 Ejectors for Vacuum Pump
Indication of Equipment
This equipment is for dental use use only. It must be operated and utilized by specialized
professional (certied professional, according to the legislation of the country) and following
the instructions of the manual. The operation of the equipment required, for the professional,
the utilization of correct instruments and it should to be in perfect conditions of the use,
and to protect the professional, the patients and others, in the eventual danger situation.
6
MODULES, ACCESSORIES, OPTIONS AND MATERIALS
OF CONSUMPTION
Syncrus L TV Water Unit
04
03
02
05
06
07
13
01
The contents of this page are of an
informative nature, the equipment
being able to differ from that
illustrated. So, upon acquiring
the product check the technical
compatibilty between equipment,
coupling and accessories.
01- Ejector type Venturi
02 - Drain plug
03 - Bowl
04 - Bowl ush spout
05 - Water unit body
06 - Bowl ush adjustment
07 - Sucker lter
13 - Driving to the water in the basin (optional)
The Drawing illustrates
the equipment with all
the optional items. Your
delivery unit will only be
composed of the items
chosen during your
purchase option.
77
MODULES, ACCESSORIES, OPTIONS AND MATERIALS
OF CONSUMPTION
Syncrus L E TV Water Unit
06
The contents of this page are of an
informative nature, the equipment
being able to differ from that
illustrated. So, upon acquiring
the product check the technical
compatibilty between equipment,
coupling and accessories.
07
01- Ejector type Venturi
02 - Drain plug
03 - Bowl
04 - Bowl ush spout
05 - Water unit body
06 - Bowl ush adjustment
07 - Sucker lter
08 - Water cupller conductor
09 - Cupller
10 - Water cupller activation
11 - Cupller ush adjustment
13 - Driving to the water in the basin (optional)
11
01
02
03
04
08
09
10
05
13
The Drawing illustrates
the equipment with all
the optional items. Your
delivery unit will only be
composed of the items
chosen during your
purchase option.
8
MODULES, ACCESSORIES, OPTIONS AND MATERIALS
OF CONSUMPTION
Syncrus L 2 T Water Unit
0607
01
The contents of this page are of an
informative nature, the equipment
being able to differ from that
illustrated. So, upon acquiring
the product check the technical
compatibilty between equipment,
coupling and accessories.
01- Ejector type Venturi
02 - Drain plug
03 - Bowl
04 - Bowl ush spout
05 - Water unit body
06 - Bowl ush adjustment
07 - Sucker lter
12 - Ejector for vacuum pump
13 - Driving to the water in the basin (optional)
04
03
02
05
13
12
The Drawing illustrates
the equipment with all
the optional items. Your
delivery unit will only be
composed of the items
chosen during your
purchase option.
99
MODULES, ACCESSORIES, OPTIONS AND MATERIALS
OF CONSUMPTION
Syncrus L E 2 T Water Unit
04
03
08
0607
11
01
The contents of this page are of an
informative nature, the equipment
being able to differ from that
illustrated. So, upon acquiring
the product check the technical
compatibilty between equipment,
coupling and accessories.
01- Ejector type Venturi
02 - Drain plug
03 - Bowl
04 - Bowl ush spout
05 - Water unit body
06 - Bowl ush adjustment
07 - Sucker lter
08 - Water cup ller conductor
09 - Cupller
10 - Water cup ller activation
11 - Cupller ush adjustment
12 - Ejector for vacuum pump
13 - Driving to the water in the basin (optional)
12
02
09
10
05
13
The Drawing illustrates
the equipment with all
the optional items. Your
delivery unit will only be
composed of the items
chosen during your
purchase option.
10
MODULES, ACCESSORIES, OPTIONS AND MATERIALS
OF CONSUMPTION
Syncrus L 2 TV Water Unit
04
03
02
06
07
01
The contents of this page are of an
informative nature, the equipment
being able to differ from that
illustrated. So, upon acquiring
the product check the technical
compatibilty between equipment,
coupling and accessories.
01- Ejectors type Venturi
02 - Drain plug
03 - Bowl
04 - Bowl ush spout
05 - Water unit body
06 - Bowl ush adjustment
07 - Suckers lter
13 - Driving to the water in the basin (optional)
05
13
The Drawing illustrates
the equipment with all
the optional items. Your
delivery unit will only be
composed of the items
chosen during your
purchase option.
1111
MODULES, ACCESSORIES, OPTIONS AND MATERIALS
OF CONSUMPTION
Syncrus L E 2 TV Water Unit
02
06
07
The contents of this page are of an
informative nature, the equipment
being able to differ from that
illustrated. So, upon acquiring
the product check the technical
compatibilty between equipment,
coupling and accessories.
01- Ejectors type Venturi
02 - Drain plug
03 - Bowl
04 - Bowl ush spout
05 - Water unit body
06 - Bowl ush adjustment
07 - Suckers lter
08 - Water cupller conductor
09 - Cupller
10 - Water cup ller activation
11 - Cupller ush adjustment
13 - Driving to the water in the basin (optional)
11
01
03
04
08
09
10
05
13
The Drawing illustrates
the equipment with all
the optional items. Your
delivery unit will only be
composed of the items
chosen during your
purchase option.
12
TECHNICAL SPECIFICATIONS
General
Product classication
In compliance with NBR IEC 60601-1
Inlet air pressure
80 PSI (5,52 BAR)
Air
Use dry and ltered air
Power inlet
12V~ and 24V~ (from Syncrus chair)
Electric shock protection type
Class one equipment
Degree of protection against electric shock
B type
Operation mode
Continuous with intermittent load
Water leak protection
IPX 0
Application together with anesthetic products that could be inammable in the
presence of air, oxygen or nitrous oxide:
Not recommended
Net Weight
Syncrus L TV Water units ............. 3,0 kg Syncrus L E TV Water units 3,2 kg
Syncrus L 2T Water units ............. 3,0 kg Syncrus L E 2T Water units 3,2 kg
Syncrus L 2 TV Water units .......... 3,0 kg Syncrus L E 2 TV Water units 3,2 kg
Gross Weight
Syncrus L TV Water units ............. 3,5 kg Syncrus L E TV Water units 3,7 kg
Syncrus L 2T Water units ............. 3,5 kg Syncrus L E 2T Water units 3,7 kg
Syncrus L 2 TV Water units .......... 3,5 kg Syncrus L E 2 TV Water units 3,7 kg
The materials used to produce the equipment are Biocompatible.
1313
TECHNICAL SPECIFICATIONS
Electromagnetic Emissions
Use of different cables, transducers and accessories from those specied may result
in increased emissions or decreased immunity of the equipment.
14
TECHNICAL SPECIFICATIONS
Electromagnetic Emissions
1515
TECHNICAL SPECIFICATIONS
Electromagnetic Emissions
16
TECHNICAL SPECIFICATIONS
Electromagnetic Emissions
List of pieces and circuit scheme
Gnatus Company declares that the supply of the circuit scheme, list of pieces or any
other information that propitiate technical attendance for the user, can be request if there
is an agreement between the user and Gnatus Company.
Standards applied:
NBR 60601-1:1997 - Equipamento Eletromédico- Parte 1: Prescrições gerais para segurança;
NBR ISO 14971:2004- Medical devices - application of risk management medical devices;
NBR ISO 9687: 2005 - Dental equipment - graphical symbols;
EN ISO 13485-2003 - Quality systems - medical devices;
IEC 60601-1-2:2007 - Compatibilidade Eletromagnética.
1717
TECHNICAL SPECIFICATIONS
Dimensions (mm)
Note: Drawing above represents a Syncrus L E TV Water Unit. All other
models have identical dimensions.
18
TECHNICAL SPECIFICATIONS
Packing symbols
It determines the maximum
quantity of boxes which can be
stacked during transportation
and storage “as per packaging”.
Packing to be transported and / or
stored with the harrows up.
Packing to be transported and /
or stored with care (should not
suffer drop and neither receive
impact).
Product symbols
Careful : It indi cates an important
instruction for the operation of the
product. Not following it can cause
dangerous malfunctioning.
Note: It indi cates useful
information for operation of the
product.
Packing to be transported and
/ or stored avoiding humidity,
rains and wet oor.
The packing must be stored and
transported away from direct
sun light exposure.
Temperature limit for the
packing to be stored or
transported.
Ejector type Venturi
B type equipment
Important: It indicates an
instruction of safety for operation
of the product. Not following it,
can lead to serious danger to the
patient.
Landing (in many parts of the
equipment) indicates the condition
of being landed.
BV ejector
Bowl’s water ow
Authorized representative in
the European Community
Warning - Consult the manual
Cup lling
1919
TECHNICAL SPECIFICATIONS
Content of accessible and non-accessible demarcations
INSTALLATION OF EQUIPMENT
The installation of this equipment requires specialized technical
assistance (Gnatus).
OBS: These information also make part of the Manual of Installation
and Maintenance of the equipment that can be found with the
authorized Gnatus technician.
- This equipment shall only be able to be unpacked and installed by a Gnatus authorized
technician, under penalty of losing the warranty, as only (s)he has the information, suitable
tools and training required to execute this task.
- Gnatus bears no responsibility for damages or accidents caused by poor installation
executed by a technician not authorized by Gnatus.
- Only after the equipment has been installed and duly tested by the authorized technician
representing Gnatus, will it be ready to start work operations.
20
OPERATION OF EQUIPMENT
Ejectors operation
The ejectors (both BV and Venturi) start
working automatically when retired from the
tips supportThe BV ejectors feature suction ow
adjustment , and its regulated moving the lever
located at the ejector up or down.
Replacement of the standard of cannula coupling
If there is the necessity of using the 6.5mm cannula in the BV suctor, make the
replacement of the cannula coupling, as the procedure below:
• Remove the coupling of 11 mm (A) by unscrewing it from.
• Screw the coupling of 6.5 mm (B) in the aspirator BV set and attach the coupling tube.
B
Coupling of tube of 6.5 mm
The curve of the coupling of the cannula was
designed for better handling, but can also be cut
at the location indicated with the aid of a knife.
A
2121
OPERATION OF EQUIPMENT
Driving and regulation of water basin
Basin water is available on all models.
To regulate the ow of water in the basin use the register (06) and to drive the ow,
press the button (13) and press it again to disable.
10
13
06
11
Driving and regulation of water in the cup holder
Water in Cup Holder (available in the L E TV, L E 2 T e L E 2 TV Syncrus Water Unit).
To drive ow of water in the cup holder, hold the button (10) until the desired amount,
to regulate the ow of water, use the register (11).
22
PRECAUTIONS, RESTRICTIONS AND WARNINGS
Transportation, storage and operation
This equipment must be transported and stored observing the following directions:
- Avoid falls and impacts;
- Keep it dry, do not expose it to rain, water drops or wet oor;
- Keep it away from water and direct sunlight, and in it original wrapping;
- Don’t move it over irregular surfaces, protect it from rain and observe the maximum
stack quantity specied in the packaging;
- Transportation and storage temperature range: -12°C to 50°C.
- Ambient temperature range recommended by Gnatus +10 ° C to +35 ° C.
The Equipment maintains its condition of safety and efcacy, provided that it is
maintained (stored) as mentioned in this instruction of use. Thus, the equipment
will not lose or alter its physical and dimensional features.
Sensitivity to environmental conditions in normal situations of use
The equipment has been planned not to be sensitive to interference such as magnetic
elds, external electrical factors, electrostatic discharge, pressure or variance of pressure,
provided that the equipment is installed, maintained, clean, preserved, transported and
operated as per this instruction for use.
Precautions and warnings “during the installation” of quipment
- The equipment should only be installed by Gnatus authorized technical assistance or
technicians.
- Position the unit in a place where it will not get wet.
- Install the unit in a place where it will not be damaged by the pressure, temperature,
humidity, direct sunlight, dust, salts, or sulfur compounds.
- The unit should not be submitted to inclination, excessive vibrations, or blows (including
during transportation and handling).
- This equipment was not planned for use in an environment where vapors, anesthetic
mixtures inammable with air, or oxygen and nitrous oxide can be detected.
- Before the rst use and/or after long interruptions from work such as vacations, clean
and disinfect the equipment; eliminate air and water deposited in the internal hoses.
These information also make part of the Manual of Installation and
Maintenance of the equipment that can be found with the authorized
Gnatus technician.
2323
PRECAUTIONS, RESTRICTIONS AND WARNINGS
Recommendations for the dental equipment maintenance.
Your Gnatus equipment has been designed and developed according to the standards
of modern techology. Similarly to other kinds of equipment, it requires special care, which
is many times neglected due to several reasons and circunstances.
Therefore, here are some important reminders for your daily routine. Try to follow these
simple rules, which will save you a lot of time and will avoid unnecessary expenses once
they start making part of your working procedure.
Precautions and warnings “during the use” of equipment
- The equipment should only be operated by duly enabled and trained technicians (Dental
Surgeons, Capacitated Professionals)
- If any maintenance should be required, only use services of the Gnatus Authorized
Technical Assistance.
- The equipment has been manufactured to handle both continuous and intermittent
operation; so follow the cycles described in these Instructions for Use.
- Although this equipment has been planned in accordance with the standards of
electromagnetic compatibility, it can, in very extreme conditions, cause interference with
other equipment. Do not use this equipment together with other devices very sensitive to
interference or with devices which create high electromagnetic disturbance.
- Do not expose the plastic parts to contact with chemical substances, use in the routines
of dental treatment, such as: acids, mercury, acrylic liquids, amalgams, etc.
Gnatus shall not be responsible for:
- Use of the equipment differing from that for which it is intended.
- Damages caused to the equipment, the professional and/or the patient by the incorrect
installation and erroneous procedures of maintenance, differing from those described in
these Instructions for use which come with the equipment or by the incorrect operation of it.
Precautions and warnings “after” the use of equipment
- Turn off the main switch of the dental set when it is not in use for an extended period
of time.
- Always maintain the equipment clean for the next operation.
- Do not modify any part of the equipment. Do not disconnect the cable or other
connections without need.
- After using the equipment, clean and disinfect all the parts which may be in contact
with the patient.
- Upon noticing irremovable stains, splits or cracks in the light conductor or in the eye
protector, replace the damaged components.
24
PRECAUTIONS, RESTRICTIONS AND WARNINGS
Precautions and warnings during the “cleaning and disinfection”
of equipment
Unidad:
- Before cleaning the equipment, turn off the main switch.
- Avoid spilling water, even accidentally, or other liquids inside the equipment, which
could cause short circuits.
- Do not use microabrasive material or steel wool when cleaning, or employ organic
solvents or detergents which contain solvents such as ether, stain remover, gasoline etc.
Precautions in case of alteration in the functioning of equipment
- If the equipment has any abnormality, check if the problem is related to any item
listed in the topic of unforeseen events (failures, causes and solutions). If it is not possible
to resolve the problem, turn off the equipment, remove the power supply cable from the
socket and contact your representative (Gnatus).
Precautions to be adopted against foreseeable or uncommon
risks, related to the deactivation and abandoning of equipment
In order to avoid environmental contamination or undue use of the Equipment after it
has become useless, it should be discarded in the suitable place (as per the local legislation
of the country).
- Pay attention to the local legislation of the country for the conditions of installation
and disposal of residue.
2525
CORRECTIVE AND PREVENTIVE MAINTENANCE AND
PRESERVATION
Additional procedures for reuse
The equipment can be reused in undetermined, i.e. unlimited, quantities, only needing
to be cleaned and disinfected.
Cleaning and Disinfection
Important: In order to execute cleaning or any type of maintenance, ensure that the
equipment is disconnected from the electrical network.
The cleaning procedure below should be executed at the start of the
working day and after each patient.
Always turn off the main switch before executing the procedures of
daily maintenance.
To clean the equipment, we recommend the use of “BactSpray
(Reg nº MS: 3.2079.0041.001-5) or any other similar product:
Active component: Benzalkonium chloride (tri-quaternary
For more information concerning cleaning procedures, see
manufacturer’s instructions.
WARNING:
- In order to prevent risks and damages to equipment, make sure
that the liquid does not enter into the unit.
- The application of other solvent-based cleaning products or
sodium hypochloride isn’t recommended, because they may damage
the equipment.
NOTE: The registration at the Ministry of Health of the “BactSpray” is executed separately
from the product described in this manual, as the “BactSpray” is not manufactured by
Gnatus.
Disinfection
Use clean and soft cloth dampened in alcohol 70% to disinfection of the equipment.
Never use corrosive disinfectants or solvents.
Note: Use gloves and other
systems of protection,
during the disinfection.
26
CORRECTIVE AND PREVENTIVE MAINTENANCE AND
PRESERVATION
Cleaning
Gnatus suggests performing a daily suction of the clearance
and disinfectant solution, avoiding the risk of cross contamination
and increasing equipment service life. To perform the disinfection
of your equipment we recommend the use of the “Sugclean” (MS
Reg. No.: 31.080.003-2) product.
• Indication: It is indicated for clearance of sucker and hose
suction system. It is important to perform the suction solution in
all suction terminals, which it is also important to be open. Then,
remove suckers from hose for asepsis.
• Preparing the Solution: Add “Sugclean” 30mL in 1 liter of
water. Aspirate the solution with maximum power of the suckers,
and also put the liquid in the water unit bowl.
In the rst use of “Sugclean” product, we suggest adding 60mL
of concentrated product in 1 liter of water during the rst 5 days
in order to remove accumulated residues.
• Composition:
• Active Drug: Phosphoric Acid 13.6%
• Excipients: Isopropyl Alcohol, Acidulant, Dye and
Thickener.
Warning: do not use foaming product.
NOTE: The registration at the Ministry of Health of the
“Sugclean” is executed separately from the product described
in this manual, as the “Sugclean” is not manufactured by
Gnatus.
Fig.A
Preventive Maintenance
The equipment should be calibrated routinely, as per the legislation in force in the country.
But never with a period exceeding 3 years.
In order to protect your equipment, seek Gnatus technical assistance for periodic revisions
of preventive maintenance.
Corrective Maintenance
If the equipment has any abnormality, check if the problem is related to any of the items
listed in the item Unforeseen Events (situation, cause and solution).
If it is not possible to solve the problem, turn off the equipment, and request Gnatus
technical assistance.
2727
CORRECTIVE AND PREVENTIVE MAINTENANCE AND
PRESERVATION
Basin cleaning
In order to obtain better results in the clean the
bowl in your water unit, we strong recommedn the
use of the product “Easy-Off Bang” or similar, nº
Reg. MS: 3.00227-0.
Chemical composition: Glycolic Acid, Maleic
Anhydride, Citric Acid, Ethoxyled Fatty Alcohol,
Essence and Water.
Apply the “Easy-Off Bang” in the water unit bowl
along with a smooth cloth up to clean it.
If you want additional information regarding
cleaness, please look at the instructions from the
product.
Cleaning of the sucker
and lters
After the suction of the solution
through the suctor, take the lid
(12) and the lter (13 or 15) and
wash them in running water.
Cleaning of the drain
Pull the drain (14) with a
tweezer, clean.
WARNING:
ALWAYS USE PROTECTION
GLOVES WHEN MANIPULATING
FILTERS AND DRAINAGES.
DISCARD WASTE AND
CONTAMINATED PRODUCTS IN
BIOLOGICAL WASTE CONTAINERS.
Filtro (A) available in all models
(Ejector type Venturi)
12
13
12
15
14
Filtro (B) available
in all models with
(Ejector for vacuum
pump)
28
UNFORESEEN EVENTS – SOLUTION OF PROBLEMS
Upon coming across any problem in operation, follow the instructions below to
check and repair the problem, and/or get in touch with your representative.
ProblemProbable causeSolution
- Ejector without suction- Insufficient air pressure
from compressor
- Filter clogged with particles
- Filter lid misplaced
- Adjust air ow
- Remove and clean lter
- Remove lid and place it
correctly
- Bowl’s water fl ow not
operating.
- Bowl’s water ow and cup
lling are not operating
- Vacuum Pump Water Valve
is closed.
- Vacuum pump is turned off.
- Lack of water
- Water valve is closed
- Lack of water
- Water valve is closed
- Power cut
- Chair’s fuse is burned
- Chair’s main switch is turn
off
- Open the Vacuum Pump
Water Valve.
- Turn on the vacuum pump.
- Check the water supply
- Open the water valve
- Check the water supply
- Open the water valve
- Check the energy supply
- Replace the chair’s fuse
- Turn on chair’s switch
2929
WARRANTY OF EQUIPMENT
This equipment is covered by the warranty terms counting from the date of installation,
as speci ed below; provided that the defect has occurred in normal conditions of use and
that the equipment has not remained stored for more than 06 months counting from the
issue date of the sales document until the date of the actual installation.
- WARRANTY TERMS: Verify the guarantee certicate;
- LOSS OF THE WARRANTY:
A) Attempt to repair using an inadequate tool or by unauthorized technicians;
B) Installation of the equipment by an unauthorized technician;
C) Damage arising from inappropriate storage or signs of infringement;
D) Incorrect use of the equipment;
E) Use of a cleaning product not indicated by the factory;
F) Falls or blows which the equipment may undergo or lack of observation of an compliance
with the guidelines of the Owner’s Manual, which was delivered with the present document,
together with the equipment. Repair or replacement of parts during the warranty period
shall not extend the validity term of their warranty.
- This warranty doe snot exempt the customer from paying the service charge for the visit
and the travel expenses of the technician, except when the customer sends the equipment
to execute the maintenance inside the establishment of the technical assistance. “Consumer
Defense Code - art. 50, unique paragraph”.
- The Warranty Certi cate comes with the product and must be lled in upon the date
of installation by the Gnatus Authorized Technician.
- Queries and information: GNATUS Help Desk (+55) 16 2102-5000.
- Check the warranty term attached to this manual.
FINAL CONSIDERATIONS
The most important aspect related to equipment care is that concerning spare parts.
To guarantee the life span of your equipment, use only original Gnatus spare parts.
They are sure to follow the technical specications and standards required by Gnatus.
We must also point out to you our chain of authorized dealers. Only dealers that make part
of this chain will be able to keep your equipment constantly new for they count on technical
assistants who have been trained and on spedic tools for the correct maintenance of your
equipment.
Doubts and information: GNATUS Call center (55-16) 2102-5000.