UNFORESEEN EVENTS – SOLUTION OF PROBLEMS ........................................55
WARRANTY OF EQUIPMENT ..........................................................................57
FINAL CONSIDERATIONS ..............................................................................57
4
IDENTIFICATION OF EQUIPMENT
Dear Customer
Congratulations. You have made a good choice when you decided to buy a GNATUS
QUALITY product comparable to the best products available in the World. This manual is a
general presentation of your product and it will give you important details to help you to
solve possible problems.
Please, read it and keep this with you.
Identication
Technical Name: Odontological cuspidor
Brand: Gnatus
Trade Name: Syncrus G8 Water Unit
55
IDENTIFICATION OF EQUIPMENT
Principles and bases applied to the functioning of the product
Unit for auxiliary work as water supply for waste collection and activation of spitting
bowls and aspirator, It has ejectors, with suction activated by a venturi system or vacuum
pump with compressed air.
Description of Equipment
Water unit for dental use, for auxiliary work as cup water supply and waste collection,
and activation of aspirators and spitting devices.
Coupled to the chair, with electronic control panel, which activates the functions water
in the basin, water in the cup holder, Bio-drive system activation, emergency stop of the
chair, *water heater and *reservoirs luminosity.
Programmable timer for water in cup holder and spitting bowl activation for a time
interval set by the professional, providing great water savings in the ofce.
The frame is manufactured with steel structure, ABS injected body with anti-UV protection.
Smooth high glossy paint, epoxy-based, cured in an oven at 250° C, with phosphate treatment
resistant to rust, corrosion and cleaning chemicals.
Upper part of the unit with suitable location for the best spitting position, 180° foldable
bowl providing total patient comfort.
Ceramic bowl spittoon, deep and easily removable for hygiene and asepsis, supplied
with strainer drain for solids retention.
Water ux regulating system allowing ne-tuning in the bowl and the cup holder water
ux.
Smooth, rounded, light and exible hoses and with quick release that is easily connected,
without the need of tools.
Has a debris lter easy to clean and disinfection.
Ejectors with automatic drive easy to use, they provide an excellent operating
performance, allow professionals to work with better visualization of the operative eld and
reduce the risk of contamination by aerosol and greater patient comfort.
*High power electric Ejectors with individual low voltage drive, provide lightness and
accuracy in the drive.
*Triple syringe swivel spout, removable and autoclavable.
*Double system for water supply (network/reservoir).
*Master valve (key for water cut).
*Amalgam separator: A system that consists in separate amalgam secretion particles.
Heavy metal extremely harmful to environment.
Arm Reach with Bilateral Catcher: terminal support with wide horizontal movement
that enables optimal approach to the surgical eld and excellent accessibility to the various
resources available. Optimizes work prioritizing the ergonomics and biosafety.
Automatic selection of tips through individual pneumatic valves, allowing light handling.
Translucent water tanks for syringe and spray tips and chlorinated water Bio-System.
*Bio-System: disinfection system, which provides the internal hose and terminals cleaning
through liquid bactericide, preventing risk of cross contamination.
EN ISO 9001/2000 and EN ISO 13485/2003 Quality System, assuryng the products
are manufactured under standart procedures.
Products manufactured in agreement with RDC 59/00 - ANVISA - (Sanitary Surveillance
National Agency).
* Optional item
6
IDENTIFICATION OF EQUIPMENT
Curing light (optional item) – Features of the product:
The Curing Light belongs to the newest generation of LED photo-activation devices. This
abbreviation stands for Light Emitting Diode, a totally different type of light emission, if
compared to conventional halogen equipment.
Unlike traditional devices, which generate wide-spectrum light and heat, this technology
uses a cold light of the precise wave length needed to activate various dental products.
LED technology, which was recently introduced in Dentistry, brought about several useful
features to those light-curing devices used in composite resin restoration. Besides being
more durable, LED technology turned devices more compact, ergonomic and easier to install
and transport. The emission of cold light within a precise wave length range ensures the
safe cure of camphorquinone-activated composites, preventing dental heating, pulp damage
or discomfort for both patient and dentist. Although being relatively new, this technology
is nowadays in its second generation. LED safety and efciency, now allied to high-energy
emission, are available to all clinic procedures which require light-curing power, including
bleaching treatments.
The light of 440nm-460nm wave length, allied to the high energy emitted by Curing
Light, makes possible the multi-functionality of this device:
- Direct restoration procedures: composite resins, ionomers and adhesives.
- Indirect restorations: adhesive cementation of laminates, inlays, esthetic pins and
metal-free crowns.
- Dental Bleaching: activation of bleaching gel and polymerization of gingival barriers.
Compatible with 35% hydrogen peroxide-based bleaching gels.
- Attachment of braces and orthodontic accessories.
- Activation of light-cure materials, such as sealants, surgical cements and covering
bases.
Designed and built with cutting-edge technology, it meets the highest standards specied
by world’s dental authorities.
Operation control display in handpiece, sound alarm with beep every 10 seconds and 4
beeps at the end of the cycle.
Advantages offered by Curing Light:
• More spectrally-selective light than conventional lamps.
• Cold light, it doesn’t heat up the resin nor the tooth.
• Light compact equipment that provides handling comfort.
• Low power consumption.
• Longer useful life of the light emitting diode (equivalent to 36.000.000 cycles of 10
seconds).
• It does not use optical lter.
• It does not require forced ventilation, thus avoiding noise emission.
We noted that the light emitted by the Curing Light is completely contained within the
absorption interval of the photo starter, therefore it’s 100% used, whereas the conventional
equipment running on halogen lamps has non-used wave-length regions.
The Curing Light doesn’t generate heat since it uses light emitting diodes.
The light conductor is removable, made out of high resistance polymer and of easy
maintenance.
77
IDENTIFICATION OF EQUIPMENT
Intra-oral camera (optional item) – Features of the product:
• Allows installation on Television set / Monitor with video / VGA Monitor input;
• Freezing of images performed through key available on the handpiece; allows the
operator greater freedom in usage;
• Installation on Computer through USB device; allows storage and management of
images through specic software;
• Image selection made through Remote Control; allows selection one by one, or four
simultaneous images directly on the television set or monitor;
• Lighting system through white LEDs with cold light, providing an image with a maximum
degree of reality;
• Built in protective lens, protects the optic components against small accidents, scratches
and dust;
• Handpiece with anatomical format; allows capturing images in any quadrant of the
mouth and allows the use of devices for prevention of cross contamination;
• Comes together with handpiece holder with automatic electromagnetic switch; allows
positioning in the most diverse locations, such as: LCD Monitors, sides of delivery unit, water
unit, cabinets, etc. Provides practicality, time and electrical power savings, turning on/off
automatically upon being removed / placed in a different position in the holder.
• Light table module, compact and functional with interfaces for diverse applications;
allows connections in VGA monitors, TV and Computer.
• Remote control with programming and image selection functions; allows greater mobility
in control and storage of captured images;
• Handpiece communication cable in highly exible material; allows exibility and does
not have the fragility found in ber optic cables;
• On/off switch placed on the handpiece, providing ease in activation;
Bicarbonate Jet Set – Jet Hand (optional item) - Product Features:
Refer to Owner's Manual of Jet Hand (available for viewing and downloading via www.
gnatus.com.br/manuais).
Indication of Equipment
This equipment is for dental use use only. It must be operated and utilized by specialized
professional (certied professional, according to the legislation of the country) and following
the instructions of the manual. The operation of the equipment required, for the professional,
the utilization of correct instruments and it should to be in perfect conditions of the use,
and to protect the professional, the patients and others, in the eventual danger situation.
8
MODULES, ACCESSORIES, OPTIONS AND MATERIALS
OF CONSUMPTION
The contents of this page are of an informative
nature, the equipment being able to differ from that
illustrated. So, upon acquiring the product check the
technical compatibilty between equipment, coupling
and accessories.
09
23
10
13
11
01 - Bilateral Catcher
*
02 - Intra oral camera
*
03 - Curing Light
*
04 - Triple syringe
*
05 - Ejectors for Vacuum Pump
06 - Control panel
07 - Alcance lid
08 - Bowl
09 - Cup holder
10 - Cabinet body
11 - Arm Alcance
*
12 - USB output
13 - Aspirator(s) lter(s)
14 - Water reservoir
Basic conguration of the product (FIT Version)
1-BV Ejector, 1-Ejector venturi.
16
17
18
08
07
06
12
03
19
2021
05
04
02
01
15 - Bio-System reservoir
16 - Cup lling
17 - Cup f Bowl ush
*
18 - Power supply
*
19 - Air output
*
20 - Water output
*
21 - Water selector valve - reservoir /net
*
22 - Master Valve - releases/blocks water input in
the dental set.
*
23 - Optical Sensor
* optional
1415
22
99
MODULES, ACCESSORIES, OPTIONS AND MATERIALS
OF CONSUMPTION
01
04
06
09
02
05
0708
10
03
abc
11
12
13
14
10
MODULES, ACCESSORIES, OPTIONS AND MATERIALS
OF CONSUMPTION
1516
* 01.Terminals:
- Borden terminal (TB)
- Midwest Terminal (TM)
- Fiber Optic Terminal (FO)
- Electric micro motor Terminal (MME)
* 02. Curing Light + 3 teeth tip
* 03. Amalgam separator
* 04. Bicarbonate jet kit “Jet Hand”
* 05. Rear panel
* a. USB output
* b. Water selector valve - reservoir /net
* c. Master Valve (System which allows cutting the ow of water and
air to the dental set)
* 06. Triple syringe with fully metal body or injected thermoplastic handle
* 07. Triple syringe with fully injected thermoplastic body
* 08. Ejectors with fully metal body or injected thermoplastic:
- Venturi ejector
- High performance Venturi type ejector
- Large ejector for Vacuum Pump
- Small ejector for Vacuum Pump
- Cleaning brush ejector
- Cannula ejector
* 09. Water bowl manufactured with injected material
* 10. Kit Chromotherapy (Programmable, multi colored LED lighting
system)
* Optional item
*Aspirators’ hoses available
in smooth and corrugated
versions.
1111
MODULES, ACCESSORIES, OPTIONS AND MATERIALS
OF CONSUMPTION
* 11. Intra oral Camera Kit
* 12. Integrated paddle "Chip Blower"
* 13. Progressive paddle
* 14. Progressive paddle with water activation/cut
* 15. Optical sensor to actuate the water supply to the bowl
* 16. Heating kit for triple syringe
Warning
- The drawing illustrates all optional items (page 10 and 11). Therefore,
your equipment will consist only of the chosen items selected during
your purchase option.
- The use of any part, accessory or material not specied or provided in
these instructions is of entire responsibility of the user.
* Optional item
12
0499
CONFIGURAÇÃO CONFIGURATIONCONFIGURACIÓN
GNATUS EQUIPAMENTOS MÉDICO ODONTOLÓGICOS S/A.
EQUIPAMENTO DE CLASSE l
CLASS l EQUIPMENT
EQUIPAMIENTO DE CLASSE l
Contínuo, com carga intermitente
Continuous, with intermittent load
Continuo, con carga intermitente
FREQUÊNCIA FREQUENCY
FRECUENCIA
12/24 V~
50/60 Hz
NUM. REG. ANVISA
APARELHO
EQUIPMENT
APARATO
OPERAÇÃO
OPERATION
OPERACIÓN
TENSÃO
TENSIONTENSIÓN
Wellkang Ltd
LONDON, W1G 9QR, U.K.
Suite B, 29 Harley Street
EC REP
MODULES, ACCESSORIES, OPTIONS AND MATERIALS
OF CONSUMPTION
+ 1 Venturi ejector
1 Syringe +1 Photo + 1 Terminal High Speed + Terminal micro motor +
1 BV ejector
Curing Light
Cup holder
Intra Oral Camera
Arm reach
Activation by electronic panel
Complete equipment
TBV
TV
2T
2 TV
2T BV
S TV
S TBV
3T
3T V
3T BV
5T
5T BV
OPTI
E
CAM
ALC
P
FULL
Identication label "responsible
eld to identify the product
conguration."
1313
TECHNICAL SPECIFICATIONS
Technical features of the Unit and its accessories
General
Model
Syncrus G8 Water Unit
Classication of Equipment as per ANVISA:
Class II
Classication of Equipment as per standard IEC 60601-1:
Protection against Electric Shock - Type B and Class I Equipment (IEC 60601-1)
Degree of safety of application in presence:
Equipment not suited to an anesthetic mixture inammable with air, oxygen or nitrous
oxide.
Mode of Operation
Continuous operation with intermittent load
Power Supply
Inlet air pressure
80 PSI (5,52 BAR)
Power Supply Voltage
24 V~
Frequency
50/60 Hz
Power
50 VA
Other specications
Capacity of water reservoir
1000ml
High rotation air consumption
9 l/min
High rotation water consumption
0,02 l/min
Inlet air pressure - Syringe
40 PSI (2,76 BAR)
14
TECHNICAL SPECIFICATIONS
Syringe air consumption
17 l/min
Syringe water consumption
0,1 l/min
Net weight (complete version)
39 Kg
Gross weight (complete version)
45 Kg
Venturi suction system – Maximum vacuum
220 mm/Hg
Venturi suction system – Volumetric displacement
30 l/min
“Bio Vac II Vacuum Pump” suction system – Maximum vacuum
400 mm/Hg
“Bio Vac II Vacuum Pump” suction system – Volumetric displacement
120 l/min
“Bio Vac IV Vacuum Pump” suction system – Maximum vacuum
550 mm/Hg
“Bio Vac IV Vacuum Pump” suction system – Volumetric displacement
350 l/min
Specications of Curring Light
Power
5,2VA
Light source
1 LED
Active medium
Semicondutor Led (InGaN)
Wavelength
440nm - 460nm
Timer
90 seconds
Timer alarm
sound alarm with beep every 10 seconds and 4 beeps at the end of the cycle
1515
TECHNICAL SPECIFICATIONS
Activation
Through the hand-piece button
Light conductor
Made out of special polymer, rotational, removable and reuse sable.
Hand-piece body
ABS injected
Specications of Intra Oral Camera
Capture element
1/4” Color CCD
Gain control
Automatic
Power
14VA
Video output
1.0Vp-p Composite/75ohm
Resolution
480 TV Line
Electronic shutter
Automatic,1/60(1/50)~ 1/100,000seg
Focal Distance
2mm - 40mm
Freezing
On the handpiece button. 60 blown-up frozen images total or on the “Grids” mode, 240
images.
Input/Output
Digital 16bits
Signal
52Db
Power supply of the module
DC 5V
Digital resolution
8 Bit 256 Grad, 512x1024 pixels
16
TECHNICAL SPECIFICATIONS
Lighting
6 LEDs
Handpiece weight
89g
The materials used to produce the equipment are Biocompatible.
Electromagnetic Emissions
Use of different cables, transducers and accessories from those specied may result
in increased emissions or decreased immunity of the equipment.
1717
TECHNICAL SPECIFICATIONS
Electromagnetic Emissions
18
Loading...
+ 42 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.