Gnatus Syncrus G8 User manual

PRESENTATION OF MANUAL
INSTRUCTIONS FOR USE
Technical Name: Odontological cuspidor
Brand: Gnatus
Trade Name: Syncrus G8 Water Unit
Manufacturer/ Distribuitor:
GNATUS - EQUIPAMENTOS MÉDICO ODONTOLÓGICOS S/A. Rod. Abrão Assed , Km 53+450m - Cx. Postal 782 CEP 14097-500 Ribeirão Preto - S.P. - Brasil Fone +55 (16) 2102-5000 - Fax +55 (16) 2102-5001 C.N.P.J. 48.015.119/0001-64 - Insc. Est. 582.329.957.115 www.gnatus.com.br - gnatus@gnatus.com.br Technical Duties: Ricardo J. Ravaneli CREA-SP: 5060714523
Registration ANVISA nº: 10229030067
ATTENTION
For greater safety:
Read and understand all the instructions contained in these
instructions for use before installing or operating this equipment.
Note: These instructions for use must be read by all the operators
of this equipment.
2
INDEX
PRESENTATION OF MANUAL ........................................................................02
IDENTIFICATION OF EQUIPMENT .................................................................05
Principles and bases applied to the functioning of the product ................................06
Description of Equipment ..................................................................................06
Indication of Equipment ...................................................................................08
MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION .....09
TECHNICAL SPECIFICATIONS .......................................................................14
- Technical features of the Unit and its accessories ...............................................14
- Electromagnetic Emissions ..............................................................................17
- List of pieces and circuit scheme .....................................................................20
- Standards applied: ........................................................................................20
- Dimensions ..................................................................................................21
- Packing symbols ............................................................................................22
- Product symbols ...........................................................................................22
- Content of accessible and non-accessible demarcations ......................................24
INSTALLATION OF EQUIPMENT ....................................................................24
OPERATION OF EQUIPMENT .........................................................................25
- Control panel ................................................................................................25
- Activation of the Terminals .............................................................................25
- Adjustment of Spray ......................................................................................26
- Ejectors operation .........................................................................................26
- Use of 3-Way Syringe ....................................................................................26
- Replacement of the standard of cannula coupling ..............................................27
- Curing Light Activation ...................................................................................28
- Water ow adjustment ...................................................................................29
- Regulation of the water selecting valve .............................................................29
- Master Valve .................................................................................................29
- How to provision the reservoirs .......................................................................29
- Amalgam separator .......................................................................................30
- Intra Oral camera ..........................................................................................31
- Water Heating ...............................................................................................31
- Brightness of the reservoirs ............................................................................31
PRECAUTIONS, RESTRICTIONS AND WARNINGS ..........................................47
- Transportation, storage and operation ..............................................................47
- Sensitivity to environmental conditions in normal situations of use .......................47
- Precautions and warnings “during the installation” of equipment ..........................47
- Recommendations for the dental equipment maintenance. ..................................48
- Precautions and warnings “during the use” of equipment ....................................48
- Precautions and warnings “after” the use of equipment ......................................48
- Precautions and warnings during the “cleaning and disinfection” of equipment .......49
- Precautions in case of alteration in the functioning of equipment ..........................49
- Precautions to be adopted against foreseeable or uncommon risks,
related to the deactivation and abandoning of equipment ......................................49
CORRECTIVE AND PREVENTIVE MAINTENANCE AND PRESERVATION............50
- Additional procedures for reuse .......................................................................50
- Cleaning and Disinfection ...............................................................................50
- Reservoirs ....................................................................................................52
33
INDEX
- Curring Light ................................................................................................52
- Triple syringe ................................................................................................52
- Cleaning of the sucker and lters .....................................................................52
- Cleaning of the drain .....................................................................................52
- Basin cleaning ..............................................................................................53
- Bio-System ..................................................................................................53
- Amalgam collecting vessel replacement ............................................................54
- Bicarbonate Jet "Jet Hand" .............................................................................54
- Preventive Maintenance .................................................................................54
- Corrective Maintenance ..................................................................................54
UNFORESEEN EVENTS – SOLUTION OF PROBLEMS ........................................55
WARRANTY OF EQUIPMENT ..........................................................................57
FINAL CONSIDERATIONS ..............................................................................57
4
IDENTIFICATION OF EQUIPMENT
Dear Customer
Congratulations. You have made a good choice when you decided to buy a GNATUS QUALITY product comparable to the best products available in the World. This manual is a general presentation of your product and it will give you important details to help you to solve possible problems.
Please, read it and keep this with you.
Identication
Technical Name: Odontological cuspidor Brand: Gnatus Trade Name: Syncrus G8 Water Unit
55
IDENTIFICATION OF EQUIPMENT
Principles and bases applied to the functioning of the product
Unit for auxiliary work as water supply for waste collection and activation of spitting bowls and aspirator, It has ejectors, with suction activated by a venturi system or vacuum pump with compressed air.
Description of Equipment
Water unit for dental use, for auxiliary work as cup water supply and waste collection, and activation of aspirators and spitting devices.
Coupled to the chair, with electronic control panel, which activates the functions water in the basin, water in the cup holder, Bio-drive system activation, emergency stop of the chair, *water heater and *reservoirs luminosity.
Programmable timer for water in cup holder and spitting bowl activation for a time
interval set by the professional, providing great water savings in the ofce.
The frame is manufactured with steel structure, ABS injected body with anti-UV protection. Smooth high glossy paint, epoxy-based, cured in an oven at 250° C, with phosphate treatment resistant to rust, corrosion and cleaning chemicals.
Upper part of the unit with suitable location for the best spitting position, 180° foldable bowl providing total patient comfort.
Ceramic bowl spittoon, deep and easily removable for hygiene and asepsis, supplied with strainer drain for solids retention.
Water ux regulating system allowing ne-tuning in the bowl and the cup holder water ux.
Smooth, rounded, light and exible hoses and with quick release that is easily connected,
without the need of tools.
Has a debris lter easy to clean and disinfection.
Ejectors with automatic drive easy to use, they provide an excellent operating
performance, allow professionals to work with better visualization of the operative eld and
reduce the risk of contamination by aerosol and greater patient comfort.
*High power electric Ejectors with individual low voltage drive, provide lightness and accuracy in the drive.
*Triple syringe swivel spout, removable and autoclavable.
*Double system for water supply (network/reservoir).
*Master valve (key for water cut).
*Amalgam separator: A system that consists in separate amalgam secretion particles. Heavy metal extremely harmful to environment.
Arm Reach with Bilateral Catcher: terminal support with wide horizontal movement
that enables optimal approach to the surgical eld and excellent accessibility to the various
resources available. Optimizes work prioritizing the ergonomics and biosafety.
Automatic selection of tips through individual pneumatic valves, allowing light handling.
Translucent water tanks for syringe and spray tips and chlorinated water Bio-System.
*Bio-System: disinfection system, which provides the internal hose and terminals cleaning through liquid bactericide, preventing risk of cross contamination.
EN ISO 9001/2000 and EN ISO 13485/2003 Quality System, assuryng the products are manufactured under standart procedures.
Products manufactured in agreement with RDC 59/00 - ANVISA - (Sanitary Surveillance National Agency).
* Optional item
6
IDENTIFICATION OF EQUIPMENT
Curing light (optional item) – Features of the product:
The Curing Light belongs to the newest generation of LED photo-activation devices. This abbreviation stands for Light Emitting Diode, a totally different type of light emission, if compared to conventional halogen equipment.
Unlike traditional devices, which generate wide-spectrum light and heat, this technology uses a cold light of the precise wave length needed to activate various dental products.
LED technology, which was recently introduced in Dentistry, brought about several useful features to those light-curing devices used in composite resin restoration. Besides being more durable, LED technology turned devices more compact, ergonomic and easier to install and transport. The emission of cold light within a precise wave length range ensures the safe cure of camphorquinone-activated composites, preventing dental heating, pulp damage or discomfort for both patient and dentist. Although being relatively new, this technology
is nowadays in its second generation. LED safety and efciency, now allied to high-energy
emission, are available to all clinic procedures which require light-curing power, including bleaching treatments.
The light of 440nm-460nm wave length, allied to the high energy emitted by Curing Light, makes possible the multi-functionality of this device:
- Direct restoration procedures: composite resins, ionomers and adhesives.
- Indirect restorations: adhesive cementation of laminates, inlays, esthetic pins and
metal-free crowns.
- Dental Bleaching: activation of bleaching gel and polymerization of gingival barriers.
Compatible with 35% hydrogen peroxide-based bleaching gels.
- Attachment of braces and orthodontic accessories.
- Activation of light-cure materials, such as sealants, surgical cements and covering
bases.
Designed and built with cutting-edge technology, it meets the highest standards specied
by world’s dental authorities.
Operation control display in handpiece, sound alarm with beep every 10 seconds and 4 beeps at the end of the cycle.
Advantages offered by Curing Light:
• More spectrally-selective light than conventional lamps.
• Cold light, it doesn’t heat up the resin nor the tooth.
• Light compact equipment that provides handling comfort.
• Low power consumption.
• Longer useful life of the light emitting diode (equivalent to 36.000.000 cycles of 10
seconds).
• It does not use optical lter.
• It does not require forced ventilation, thus avoiding noise emission.
We noted that the light emitted by the Curing Light is completely contained within the absorption interval of the photo starter, therefore it’s 100% used, whereas the conventional equipment running on halogen lamps has non-used wave-length regions.
The Curing Light doesn’t generate heat since it uses light emitting diodes.
The light conductor is removable, made out of high resistance polymer and of easy maintenance.
77
IDENTIFICATION OF EQUIPMENT
Intra-oral camera (optional item) – Features of the product:
• Allows installation on Television set / Monitor with video / VGA Monitor input;
• Freezing of images performed through key available on the handpiece; allows the
operator greater freedom in usage;
• Installation on Computer through USB device; allows storage and management of
images through specic software;
• Image selection made through Remote Control; allows selection one by one, or four
simultaneous images directly on the television set or monitor;
• Lighting system through white LEDs with cold light, providing an image with a maximum
degree of reality;
• Built in protective lens, protects the optic components against small accidents, scratches
and dust;
• Handpiece with anatomical format; allows capturing images in any quadrant of the
mouth and allows the use of devices for prevention of cross contamination;
• Comes together with handpiece holder with automatic electromagnetic switch; allows
positioning in the most diverse locations, such as: LCD Monitors, sides of delivery unit, water unit, cabinets, etc. Provides practicality, time and electrical power savings, turning on/off automatically upon being removed / placed in a different position in the holder.
• Light table module, compact and functional with interfaces for diverse applications;
allows connections in VGA monitors, TV and Computer.
• Remote control with programming and image selection functions; allows greater mobility
in control and storage of captured images;
• Handpiece communication cable in highly exible material; allows exibility and does
not have the fragility found in ber optic cables;
• On/off switch placed on the handpiece, providing ease in activation;
Bicarbonate Jet Set – Jet Hand (optional item) - Product Features:
Refer to Owner's Manual of Jet Hand (available for viewing and downloading via www. gnatus.com.br/manuais).
Indication of Equipment
This equipment is for dental use use only. It must be operated and utilized by specialized
professional (certied professional, according to the legislation of the country) and following
the instructions of the manual. The operation of the equipment required, for the professional, the utilization of correct instruments and it should to be in perfect conditions of the use, and to protect the professional, the patients and others, in the eventual danger situation.
8
MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION
The contents of this page are of an informative nature, the equipment being able to differ from that illustrated. So, upon acquiring the product check the technical compatibilty between equipment, coupling and accessories.
09
23
10
13
11
01 - Bilateral Catcher
*
02 - Intra oral camera
*
03 - Curing Light
*
04 - Triple syringe
*
05 - Ejectors for Vacuum Pump 06 - Control panel 07 - Alcance lid 08 - Bowl 09 - Cup holder 10 - Cabinet body 11 - Arm Alcance
*
12 - USB output
13 - Aspirator(s) lter(s)
14 - Water reservoir
Basic conguration of the product (FIT Version)
1-BV Ejector, 1-Ejector venturi.
16
17
18
08
07
06
12
03
19
20 21
05
04
02
01
15 - Bio-System reservoir
16 - Cup lling 17 - Cup f Bowl ush
*
18 - Power supply
*
19 - Air output
*
20 - Water output
*
21 - Water selector valve - reservoir /net
*
22 - Master Valve - releases/blocks water input in
the dental set.
*
23 - Optical Sensor
* optional
1415
22
99
MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION
01
04
06
09
02
05
07 08
10
03
a b c
11
12
13
14
10
MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION
15 16
* 01.Terminals:
- Borden terminal (TB)
- Midwest Terminal (TM)
- Fiber Optic Terminal (FO)
- Electric micro motor Terminal (MME)
* 02. Curing Light + 3 teeth tip
* 03. Amalgam separator
* 04. Bicarbonate jet kit “Jet Hand”
* 05. Rear panel * a. USB output * b. Water selector valve - reservoir /net
* c. Master Valve (System which allows cutting the ow of water and
air to the dental set)
* 06. Triple syringe with fully metal body or injected thermoplastic handle
* 07. Triple syringe with fully injected thermoplastic body
* 08. Ejectors with fully metal body or injected thermoplastic:
- Venturi ejector
- High performance Venturi type ejector
- Large ejector for Vacuum Pump
- Small ejector for Vacuum Pump
- Cleaning brush ejector
- Cannula ejector
* 09. Water bowl manufactured with injected material
* 10. Kit Chromotherapy (Programmable, multi colored LED lighting system)
* Optional item
*Aspirators’ hoses available in smooth and corrugated versions.
1111
MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION
* 11. Intra oral Camera Kit
* 12. Integrated paddle "Chip Blower"
* 13. Progressive paddle
* 14. Progressive paddle with water activation/cut
* 15. Optical sensor to actuate the water supply to the bowl
* 16. Heating kit for triple syringe
Warning
- The drawing illustrates all optional items (page 10 and 11). Therefore, your equipment will consist only of the chosen items selected during your purchase option.
- The use of any part, accessory or material not specied or provided in
these instructions is of entire responsibility of the user.
* Optional item
12
0499
CONFIGURAÇÃO CONFIGURATIONCONFIGURACIÓN
GNATUS EQUIPAMENTOS MÉDICO ODONTOLÓGICOS S/A.
EQUIPAMENTO DE CLASSE l
CLASS l EQUIPMENT
EQUIPAMIENTO DE CLASSE l
Contínuo, com carga intermitente Continuous, with intermittent load Continuo, con carga intermitente
FREQUÊNCIA FREQUENCY
FRECUENCIA
12/24 V~
50/60 Hz
NUM. REG. ANVISA
APARELHO
EQUIPMENT
APARATO
OPERAÇÃO
OPERATION
OPERACIÓN
TENSÃO
TENSIONTENSIÓN
Wellkang Ltd
LONDON, W1G 9QR, U.K.
Suite B, 29 Harley Street
EC REP
MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION
Units may be made composed by:
Optional Acronyms
1 BV ejector 1 Venturi ejector
1 Venturi ejector + 1 BV ejector 2 Venturi ejectors 2 BV ejectors 1 Syringe + 1 Venturi ejector 1 Syringe + 1 BV ejector 1 Syringe + 1 Venturi ejector +1 BV ejector 1 Syringe + 2 Venturi ejector 1 Syringe + 2 BV ejector 1 Syringe + 1 Photo +1 Terminal High Speed + 1 Terminal micro motor
+ 1 Venturi ejector 1 Syringe +1 Photo + 1 Terminal High Speed + Terminal micro motor +
1 BV ejector Curing Light Cup holder Intra Oral Camera Arm reach Activation by electronic panel Complete equipment
TBV TV
2T 2 TV 2T BV S TV S TBV 3T 3T V 3T BV 5T
5T BV
OPTI E CAM ALC P FULL
Identication label "responsible eld to identify the product conguration."
1313
TECHNICAL SPECIFICATIONS
Technical features of the Unit and its accessories
General
Model Syncrus G8 Water Unit
Classication of Equipment as per ANVISA:
Class II
Classication of Equipment as per standard IEC 60601-1:
Protection against Electric Shock - Type B and Class I Equipment (IEC 60601-1) Degree of safety of application in presence:
Equipment not suited to an anesthetic mixture inammable with air, oxygen or nitrous
oxide. Mode of Operation Continuous operation with intermittent load
Power Supply
Inlet air pressure 80 PSI (5,52 BAR) Power Supply Voltage 24 V~ Frequency 50/60 Hz Power 50 VA
Other specications
Capacity of water reservoir 1000ml High rotation air consumption 9 l/min High rotation water consumption 0,02 l/min Inlet air pressure - Syringe 40 PSI (2,76 BAR)
14
TECHNICAL SPECIFICATIONS
Syringe air consumption 17 l/min Syringe water consumption 0,1 l/min Net weight (complete version) 39 Kg Gross weight (complete version) 45 Kg
Venturi suction system – Maximum vacuum
220 mm/Hg
Venturi suction system – Volumetric displacement 30 l/min “Bio Vac II Vacuum Pump” suction system – Maximum vacuum
400 mm/Hg
“Bio Vac II Vacuum Pump” suction system – Volumetric displacement
120 l/min
“Bio Vac IV Vacuum Pump” suction system – Maximum vacuum
550 mm/Hg
“Bio Vac IV Vacuum Pump” suction system – Volumetric displacement
350 l/min
Specications of Curring Light
Power 5,2VA Light source 1 LED Active medium Semicondutor Led (InGaN) Wavelength 440nm - 460nm Timer 90 seconds Timer alarm sound alarm with beep every 10 seconds and 4 beeps at the end of the cycle
1515
TECHNICAL SPECIFICATIONS
Activation Through the hand-piece button Light conductor Made out of special polymer, rotational, removable and reuse sable. Hand-piece body ABS injected
Specications of Intra Oral Camera
Capture element 1/4” Color CCD Gain control
Automatic
Power
14VA Video output
1.0Vp-p Composite/75ohm Resolution 480 TV Line
Electronic shutter
Automatic,1/60(1/50)~ 1/100,000seg
Focal Distance
2mm - 40mm
Freezing On the handpiece button. 60 blown-up frozen images total or on the “Grids” mode, 240
images. Input/Output
Digital 16bits Signal 52Db
Power supply of the module
DC 5V
Digital resolution
8 Bit 256 Grad, 512x1024 pixels
16
TECHNICAL SPECIFICATIONS
Lighting
6 LEDs
Handpiece weight
89g
The materials used to produce the equipment are Biocompatible.
Electromagnetic Emissions
Use of different cables, transducers and accessories from those specied may result
in increased emissions or decreased immunity of the equipment.
1717
TECHNICAL SPECIFICATIONS
Electromagnetic Emissions
18
Loading...
+ 42 hidden pages