In order to preclude any danger to the operator, the following instructions
should be followed:
a)In case any damage or malfunction is detected, take the unit out of operation without delay.
b)Before disassembling the unit, disconnect all inputs / outputs and the supply voltage. When
mounting the unit and the connections, make sure all live components are protected from
being touched directly.
c)Comply with the usual regulations and safety provisions for low and high current systems, in
d)The maximum admissible potential existing between the pin groups as well as to the external
protective conductor must not be exceeded. Refer to the unit´s identification label.
e)When connecting the unit to other devices (e.g. PCs), the connection must be carefully
planned. Internal connections in external units (e.g. GND connected to protective earth) may
cause excessive voltage potential.
f)This device must be grounded! For low voltage 12VDC and 24V
Units with a.c. supply voltage must be connected the protective conductor.
g)Make sure that the unit is property mounted before connection and power on !
In order to preclude any damage to the unit, the following items must be
taken into account:
The maximum admissible potential between the pin groups must not be exceeded.
This applies in particular to high voltage tests.
Refer to the instruction manual !
systems use screened cable.
DC
Warning: Hazardous live voltage !
WARNING:
There is always hazardous voltage present in certain parts during the operation of electrical equipment.
Non-observance of the safety instructions can result in severe personal injury or damage to property. Only qualified personnel should
work on this equipment. The successful and safe operation of this equipment is dependant on proper transport, storage, set-up,
installation and careful operation and maintenance.
QUALIFIED PERSONNEL
Are personnel who are familiar with the set-up, installation, commissioning and operation of the product and have the qualifications
corresponding to their activities, e.g.:
- Are trained and authorised to energise, de-energise, clear, ground and tag circuits and equipment / systems in accordance with
established safety standards.
- Are trained in the proper care and use of protective equipment in accordance with established safety practices.
- Are trained in first aid.
Safety according to EN 61010-1, VDE 0411
CAT III > 150 V [ 300 V
Pollution degree:2; indoor use; altitude <2000 m; relative humidity <80 % up to 31 °C;
T emperature:5 °C to 40 °C;
Table of Contents
page
I. IPP 144 - 40 G / IPP 144 - 40 GE 3 - 60
1.General Features3 - 5
2.Technical Data6 - 9
2.1. Basic Version6 - 8
2.2. Version E9
3.Design and Installation10 - 11
4.Connection11 - 17
4.1. Pin assignment11 - 13
4.2. Interface selection14
4.3. Connecting Diagram serial15 - 17
5.Operation18 - 23
5.1. Operating Controls18 - 19
5.2. Replacing the paper roll20
5.3. Menu program21 - 23
6.Adjustments24 - 29
6.1. General Functions24 - 25
6.2. Serial Interfaces25 - 26
6.3. Date / Time26 - 28
6.4. Date / Time Output28 - 29
7.Functional Description30 - 35
7.1. Start Printing30
7.2. Addressing30 - 31
7.3. Handshakes Messages31 - 33
7.4. Version E (IPP 144-40 GE)33 - 35
7.4.1. Texts Entry33 - 34
7.4.2. Texts Output35
page
8.Appendix36 - 56
8.1.Menu program complete Selection36 - 37
8.2.Character Sets38 - 40
8.3.Details of Printer Control41 - 53
Commands
8.3.1. Short View of Control
Commands41
8.3.2. Print Character Commands41 - 44
8.3.3. Print Position Commands44 - 45
8.3.4. Bitmap image Commands45 - 49
8.3.5. Line Feed Commands49
8.3.6. Barcode Commands50 - 53
8.4.Connection Examples
for GMW instruments54 - 55
8.4.1. Connection with DPM / MF54
8.4.2. Coupling with DAA55
8.5.Examples for Automatic
Text Insert Mode56
II.Paper Reroll
Mechanism IPP - AW57 - 60
1.General information57 - 58
Design / Installation58
2.Technical data59
3.Operation60
III.Accessories61
1
Index
page
Accessories61
Addressing26, 30
Addressing & protocol / text31
Basic version5
Baudrate25
Barcode Commands50
Bitmap image Commands45
Character set24, 38
Connection diagrams11
Connection Examples54
Control characters38
Data format - serial25
Date / time - output via interface II28
Date / time - setting26
End of paper indication18
Environmental conditions7
Enhanced version (E - version)5
Graphic print-out directly19
from WINDOWS®
Handshake serial - RTS / DTR31
Handshake serial - XON / XOFF32
Headline data & time29
Input buffer7
Installation10
Interface selection14
Key LINE FEED / ENTER18
Key lock19
Key MENU / SELECT18
KEY RESET19
Line Feed Commands49
Line with (character per line)24
Mechanical data8
Menu program - complete selection36
Menu program - entry21
Menu program - quitting22
Model types4
page
Operating controls, general18
Paper6
Paper reroll mechanism57
Parameters, changing22, 23
Parameters, printing the current21
Parity25
Pin assignment current loop16
Pin assignment - interface I15
Pin assignment - interface II17
Print Character Commands41
Print Control Commands40
Print format24
Print interval - serial32
Print interval - setting24
Print mechanism6
Print Position Commands44
Protocol - serial29
Replacing the paper roll20
Snap lock18
Software version8
Start printing30
Technical Data6
Text adding, overwrite33
Text call with measured data, serial34
Text - deleting33
Text entry33
Text entry - block34
Text entry - wildcards28
Text output35
Voltage supply7
Wildcards for measure value34
Windows programming software5
2
I. IPP 144 - 40 G / IPP 144 - 40 GE
1. General Features
The Thermal Graphics Printer IPP 144-40 G (Industrial Process
Printer) is a device designed for outputting text, data and
graphics, i.e. measured value, machine and process states, error
messages, production data, etc.
T wo application examples:
.
If connected to a digital voltmeter , the IPP 144-40 G records
the measuring values (with date/time for the E version).
.
Its integrated interface allow the use of the IPP 144-40 G as
a peripheral for all PLCs (RS 232 C; RS 422; RS 485; USB;
Profibus DP).
The Thermal Graphics Printer is a DIN size panel mounting unit
which is able to print line widths of up to 48 characters per line.
The 14m paper roll (commercial grade document proof thermal
paper) is located inside the housing and can be easily replaced
by means of a swivel type front panel. Án end of paper indicator
lights up if the printer runs out of paper .
3
Each printer is addressable, which allows the connection of
up to 31 devices to one sender device via a data line at the
RS 485 interface, e.g. to a PLC.
Review of the
model types
Model
IPP 144-40 G
IPP 144-40 GE 232
IPP 144-40 GE 485
IPP 144-40 GE PB
IPP 144-40 GE USB
There are two version of the printer: The Basic V ersion
IPP 144-40 G with the interface I and the Enhanced V ersion
IPP 144-40 GE with the interfaces I and II.
There are three option for the voltage supply: 12V DC (10V ...19V
DC) or 24V DC (19V ...36V DC) or 1 10V/230V AC (switch-mode
power supply: 85V ...265V AC)
There are four option for the interface IIl :
RS 232 C, RS 485, ProfiBus or USB
Supply Voltage
12V DC 24V DC110/230V AC
12V DC 24V DC110/230V AC
12V DC 24V DC110/230V AC
12V DC 24V DC110/230V AC
12V DC 24V DC110/230V AC
Interface I
Yes
Yes
Yes
Yes
Yes
The connector for the interface II of RS 232 C, RS 485 and
ProfiBus is a 9 pin D-Sub-socket. It is possible to change this
interface card in the factory . The interface option USB has a
special USB-B-socket. It is not possible to change this
interface card with the other cards. Special adapter cables
and converters are used in this situation.
4
WindowsProgramming
software
A Windows-Programming software has been developed.This
software will be available to progam the GE text memory , transfer
user defined fonts or symbols and set the printer configuration
parameters. Also this software package includes actual
Windows printer drivers.
The software will be on CD-ROM.
Basic Version
IPP 144-40 G
Enhanced
Version
IPP 144-40 GE
The basic version IPP 144-40 G provides one serial interface
capable of receiving only. Return (handshake) messages to
the sender are sent via hardware line. Texts and measuring
value to be printed must be transmitted from the sender device
since the basic version does not have an internal text memory .
It is possible to print with the basic version bitmap image and
barcodes. The bitmap image files and the barcode files are
generated with printer control commands in a terminal emulation
program.These files are transmitted by interface I to the
printer. It is possible to download this file onto the font ROM
chip in the printer. For the printer control commands and
download commands see section 8.3. in this manual.
Note: The cyrillic character set is on the font ROM chip.
If user defined fonts or symbols are downloaded onto the font
ROM chip, the cyrillic character set will be overwritten, and
the cyrillic character set will no longer be available.
The enhanced version IPP 144 - 40 GE provides a second,
bi-directinal serial interface capable of outputting return
messages under program control in compliance with a protocol.
In addition, this model includes a text memory capable of
storing up to 15 texts which are called by specifying the
corresponding text number. Moreover, date and time may be
printed with texts and data.
The printer interfaces of the IPP 144-40 GE can be set in the
menu program as serial transfer or standard Windows printer
drivers. So it is possible to print data (e.g.user defined fonts
and symbols) directly with Windows.
It is not possible for the user to upgrade the basic version to
the enhanced version; as this is a different factory version.
5
2. Technical Data
2.1.Basic Version
Print
mechanism
Paper
Type of printingFixed head thermal line
Character representation576 dots/line, 8 dots/mm
Print speed approx.15 line/s (standard text mode)
Character/line48 characters
24 characters
16 characters
8 characters
Character height 3 mm at 48 characters
4 mm at 24 characters
9 mm at 16 characters
18 mm at 8 characters
Character setsASC II, german,
french, danish,
norwegian,
swedish / finnish,
spanish, english, cyrillic
Service lifemin. 10x106 Impulse or 50 km
T yp ecommercial grade,
document proof
thermal paper
Width80 mm (+0 / -1 mm)
Lengthapprox. 14 m
(approx. 4.600 line
up to 48 characters per line)
Max. outer roll diameter40 mm
Min. inner roll diameter1 1,5 mm
Temperaturestandard paper: 0 °C to 60 °C
6
Input buffer
Serial
Interface I
Serial16 kB
T y p eRS 232 C; RS 422; RS 485
or Current loop
Baudrate110; 150; 300; 600; 1200;
2400; 4800;9600;19200;
38400
Data format7 bit / 8 bit
1)
Parity biteven, odd, mark, space, no
1)
Voltage
supply
Ambient
conditions
Standards
Safetyacc. to EN 61010-1:2001
CA T III > 150 V ≤ 300 V
pollution degree 2
DC10 V ... 19 V
approx. 20 V A
2)
19 V ... 36 V
approx. 18 V A
2)
AC85 V ... 265 V , 45 - 65 Hz,
approx. 15 W
switch-mode power supply
Storage temperature range-20 °C to +60 °C
Operating temperature range 0 °C to +45 °C
Climaterelative humidity < 80 %
up to 31 °C
Protection typeacc. to EN 60529/VDE 0470
housingIP 50
terminalsIP 00
Insulation groupC acc. to VDE 0110
Mech. strengthacc. to IEC 1010
EMC
EmissionEN 5501 1, Class A
EN 55022, Class B
SusceptibilityEN 61000-4-2 B
EN 61000-4-3 A
EN 61000-4-4 B
CE
1)
See setting transmission parameters of the sender at page 9.
2)
Starting current approx. 1,2 A (10 V ... 19 V) or approx. 0,8 A
(19 V ... 36 V).
This value can be used to rate the external fuse.
Connection for paper
reroll mechanism4pin MASCON, MLAS
Connection for
Alarm relay output
Screw type/terminal
fixed:0,2 to 4 mm²
flexible:0,2 to 2,5 mm²
AWG:24 to 12
normally open
50 V AC, 2 A
30 V DC, 2 A
Miscellaneous
8
Dimensions
(W x H x D)144 x 72 x 159 mm
Switchboard mountingscrews against rear side
of switchboard
Internal fuse
( on power supply board)12V DC: T 3,15 A
24V DC: T 2 A
1 10V - 230V AC : T 2 A
This operating manual applies to software version
5.01.05 and higher
2.2. V ersion E
Serial
Interface II
Text entry for
texts to be
stored
Text memory
Internal clock
Warning !
T y p eRS 232 C or RS 485
1)
ProfiBus or USB
Baudrate110: 150; 300; 600; 1200;
2400; 4800; 9600;19200;38400
Data format7 bit / 8 bit
Parity biteven, odd, mark, space, no
2)
2)
separate configuration
by interface II
T yp eCMOS-RAM, battery buffered
3)
Battery life10 years typical
Memory size600 Byte = 15 texts
T yp eCMOS, battery buffered
Accuracy± 10 ppm = 0,8 sec / day
1)
Please specify when ordering; if nothing is specified, RS 232 C is
supplied.
2)
See Setting transmission parameters of the sender
3)
Lithium battery: 3 V
type:VARTA CR 2/3 AA Typ 6237
PANASONIC BR 2/3 A 1 P
^
3)
^
This product contains a Lithium battery which must not be
cut open, incinerated, exposed to temperature above
+60 °C or recharged.
Dispose of in accordance with national regulations.
9
Design
3. Design and Installation
Front
10
1 Paper and cutting edge
2 Key: LINE / FEED / Enter
3 Key: MENU / Select
4 Alarm LED (paper end indicator)
5 Serial interface
Interface II (only version E)
6 Serial Interface I
7 Voltage supply
Make sure that the unit is properly
mounted before connection and power on.
8 Alarm contact
(paper end only version E)
9 Snap lock
10 Mounting screws
11 Protective conductor
connection. Must be
connected to ground.
12 Connection / paper reroll
mechanism IPP-AW
Installation
The IPP 144 - 40 G fits into a DIN standard panel cut out. It
is inserted into the switchboard opening from the front side
and is fixed against the switchboard rear using mounting
screws. The switchboard thickness must not exceed 12 mm.
4. Connection
4.1. Pin assignments
Pin
assignment
WARNING: This device must be grounded -ACHTUNG: Dieses Gerät muss geerdet werden !
IPP 144 - 40 G
Opt.: . . . . . . .
EN 61010 -1:2001 CAT III
.
CE
Alarm
-
+
LN
1
85 V...265 V AC; 45...60Hz ; 15W
19 V...36 V DC; 18 VA
10 V...19 V DC; 20 VA
Interface II
RS 232 C
RS485
Profi Bus
USB
IPP-AW
Interface I
5
5
Sig GND
9
Sig GND
RXD (-
)
9
TXD
RTS
DTR
CLA
+5Vis
RTS
RTS
DTR
RXD
GND
1
6
GND
RXD (+)
1
6
DTR
Serien Nr.:
Serial No.:
No.de serie
Lithium battery inside ( VERSION E )
TXD
Connect the unit as shown in the connection diagramms.
Observe all national safety regulations, especially for the supply power
connections.
11
Serial
Interface I
PinSignal
1GNDGround (shield)
2RXD (+)Receive data
3+5 VOutput +5 V / 20 mA
4n.c.
5RXD (-)Signal ground
6DT ROpen collector; active if
DTR is +8 V
12
7DT R(Data Terminal Ready)
+8 V: ready to receive
-7 V: not ready to receive
8RTS(Request To Send)
+8 V: ready to receive
-7 V: not ready to receive
(text buffer is full)
9RTSOpen Collector; active if
RTS is +8 V
The serial interface I has been designed to allow the
implementation of all widely used interfaces:
RS 232 C; RS 422; RS 485 and Current loop.
See chapter 4.3.: Connecting diagram
Serial
Interface II
(only
IPP 144 -40 GE)
PinSignal
1G NDGround (shield)
2RXD (+)Receive data
3n.c.
4TXDTransmit data
5RXD (-)Signal ground
6n.c.
7D T R(Data T erminal Ready)
+8 V: ready to receive
-7 V: not ready to receive
8R TS(Request T o Send)
+8 V: ready to receive
-7 V: not ready to receive
9n.c.
This interface can either be operated under hardware
handshake (DTR, RTS) or software handshake
(XON / XOFF - Protocol). This does not require special
settings.
See chapter 4.3.: Connecting diagram
13
4.2. Interface selection (Interface I)
Slide snap lock to the right hand side, swivel front door out.
Now you can see the switch S 101 on the printed circuit
board.
-For RS 232 C, RS 422 and RS 485 set switch S 101
to the right hand side.
-For Current loop, set switch S 101 to the left hand
side.
14
IMPORTANT:
This switching only applies to interface I.
If the printer is connected to the sender device
(e.g. to a PLC) the interface parameters must be
matched to those at the sender device.
See chapter 6.2. which describes the setting of
the baudrate, data format, stop bit and parity bit.
RS 232 C
RS 422
4.3. Connecting diagram
Interface I
Set slider switch S 101 to the right hand side !
(see „Interface selection“ 4.2.)
RS 485
SenderIPP 144
See explanation on page 17
15
Current loop
Sender active,
IPP 144 - 40 G
passive
Sender passive
IPP 144 - 40 G
active
Set slider switch S 101to the left hand side !
(see „Interface selection“ 4.2.)
Sender activeIPP 144-40G passive
Sender passiveIPP 144-40G active
16
100 Ohm
„I“identifies the direction in which the current flows (20 mA)
RS 232 C
RS 485
(Option)
ProfiBus
(Option)
Interface II
USB
(Option)
Sender / receiverIPP 144-40 GE
Explanation concerning the signal names underRS 485.
The names A, B, C correspond to the EIA 485 - Standard:
inactive or logical „1“; A > B
logical „0“: B > A
If an interface does not comply with that standard, the
connections of A and B must be interchanged.
Standard USB chassis socket type B
pin 1 +5V
pin 2 U SBD M
pin 3 USBDP
pin 4 G N D
17
5. Operation
5.1. Operating Controls
The numbers with the operating controls refer to the
diagrams in chapter 3.
LED
„Alarm“
(4)
LINE FEED /
ENTER
(2)
The ALARM LED has two functions.
1. T o indicate „end of paper“ or „no p aper“
2. To indicate the front door is open
Examples:
1. The front door is closed.
If this LED is lit, the printer has run out of paper . Insert a
new paper roll; see section 5.2. „Replacing the Paper Roll“.
the front press-button switches (LINE FEED & MENU keys)
are deactivated.
2. The front door is open.
The LED is lit. Printing may continue until the input buffer is
empty , and then the data transmission goes to st andby.
3. The front door is open and the printer has run out of
paper .
The LED lit. The printer stops printing and the front pressbutton switches are deactivated.
After replacing the paper roll the front press-button
switches are active. The ALARM LED remains ON until the
front door is closed. The printer can start working.
This key has two functions:
LINE FEED:
During operation used for manual paper feed.
In the menu program it is used to accept and save
the parameters selected via „Select“.
MENU /
SELECT
(3)
18
This key has two functions:
MENU:
If during operation this key is pressed continuously
for more than 3s, the printer switches to menu
program mode in which device parameters are printed
out and can be modified.
Select:
Within the menu program it is used for selecting the
device parameters.