GMTCNT GOP43-070ET, GOP43-070ETE Installation Instruction

Bağlantı
Standart RJ45 ethernet kablosu.
Port
Fonksiyonu
Port Program yükleme / alma, onlne simülasyon, bu port üzerinden birden çok HMI birbirlerine bağlanabilir. HMI PLC arasında ethernet portu ile haberleşme sağlanabilir.
Bağlantı
Standart USB kablosu ile bilgisayara bağlayınız
Port
Fonksiyonu
Program download/upload yapılabilir.
Pin
Symbol
COM0
PLC
[RS-485]4wire
COM0
PLC
[RS-485]2wire
COM0
PLC
[RS-232]
COM2
PC/PLC
[RS-232]
1
Rx-(B)
RS-485 Rx
RS485 B
2
RxD_PL
C
RS-232 Rx
3
TxD_PL
C
RS-232 Tx
4
Tx-
RS-485 Tx
5 GND
Signal Ground
6
Rx+(A)
RS-485 Rx
RS485 A
7
RxD_PC
RS-232 Rx
8
TxD_PC
RS-232 Tx
9
Tx+
RS-485 Tx
Bağlantı
Standart USB kablosu ile bilgisayara bağlayınız
Port
Fonksiyonu
Bu port ile USB klavye, Mouse ve yazıcı bağlanabilir. Harici flash disk bağlantısı ile program yükleme/alma ve data kayıt yapılabilir.
GMTCNT GOP43-070ET/ETE
Human Machine Interface Operatör Panel
Kullanım Talimatları
1. Kurulum Hakkında Notlar
2. Montaj Açıklamaları
3. Bağlantı Diyagramı
Elektriksel, elektrostatik
veya elektromanyetik gürültünün bulunduğu
Güç kayanağına yakın
ortamlarda ekranlama yapınız.
Doğrudan güneş ışığının alındığı Hızlı sıcaklık değişiminin veya yüksek
nemin olduğu
Patlama tehlikesi olan  Yanıcı gazların bulunduğu Buharlı ve tozlu  Sarsıntılı veya titreşimli
ortamlarda kullanmayınız.
4. İşletim Modu
1.1 Çevre Şartları
Cihazın montajı yapılırken, AC güç kablolarının, PLC çıkış modüllerinin, kontaktörlerin, rölelerin ve buna benzer diğer elektriksel birimlerin cihazın arka bölgesinden uzakta olmasına özen gösterilmelidir.
1 2 3 4 5 6 7 8 9
1.2 Güç Gereksinimleri
Giriş Gerilimi: 12~28VDC;
Ürün ve konverterler veya kesintisiz güç kaynağı arasında yeterli mesafe olmalıdır. Bu
DC kaynaklar ana AC güç kaynağından izole edilmelidir. . Sürekli yük veya kontrol cihazının giriş devresi ile ortak güç kullanmayınız.
İçerdeki sigorta aşırı gerilim durumunda cihazın zarar görmesini
önleyecektir. Ancak, içerdeki elektronik parçaların zarar görmeyeceği
garanti edilmemektedir.
2.3 Güç Bağlantıları
Güç kaynağı kabloları için lütfen güvenlik şartnamelerine uygun olan dielektrik değere
ve akım değerlerine sahip kablolar seçiniz. Güç terminalleri paketleme kutularının içerisinde paketlenmiş haldedir.
DC hattının artısını ‘DC24V’ terminaline ve eksisini de ‘-’ terminaline bağlayınız.
3.1 USB SLAVE
3.2 COM0&COM2
9 pinli erkek D-SUB’un COM0 RS–232/485/422 destekler COM2 RS232 destekler. bağlamak için kullanılır.
2.1 Ebatlar (mm)
2.2 Montaj Talimatları
Cihazı yuva kesiti içerisine yerleştiriniz. Kutunun etrafındaki 4 adet tutturma aparatını kaydırın. Vidaları eşit bir şekilde, operatör panelin içine sağlam bir şekilde tutturulduğunda emin oluncaya kadar sıkınız
3.3 USB HOST
3.4 Ethernet (GOP43-070ETE)
4.1 İşletim mode seçim penceresime giriş
Cihaza enerji verilmeden önce ekrana basılı tutulup enerji verildiğinde seçim penceresi
görünecektir.
4.2 İşletim mode seçim penceresi modları
NEMA–4 özelliklerinin ayarlarını yapmak için, tüm montaj aparatları
kullanılmalıdır ve panel eğilmemelidir.
Montaj aparatlarını aşırı derecede sıkmamaya özen gösteriniz!
System Setup Bu menüden açılış penceresi numarası, screen saver zamanı , buzzer actik pasif ,parlalklık gibi ayarlamalar yapabilirsniz.
Firmware UpdateFirmware güncelleme için kullanılan bu menu bilinçli kullanılmalıdır. Touch CalibrationDokunmatik ekran kalibrasyonu menüsüdr. Stop timer: 20s lik zamanlayıcıyı durdurmak için kullanılar. Zamanlayıcı herhnagi birr işlme
yapılamdığ zman bekleme süresidir.
GMT Endüstriyel Elektronik San. ve Tic. Ltd. Şti. Kavacık Mah. Yurtsever Sk. No:2 Beykoz / İstanbul -Turkey
Tel : +90 216 668 0006 Pbx. Fax : +90 216 668 0008 url : www.gmtcontrol.com
Pin
Signal
PLC
[RS-485]4wire
PLC
[RS-485]2wire
PLC
[RS-232]
PLC
[RS-232]
1
Rx-(B)
RS-485 Rx
RS485 B
2
RD_PLC
RS-232 Rx
3
TD_PLC
RS-232 Ex
4 Ex-
RS-485 Ex
5 GND
Signal Ground
6
Rx+(A)
RS-485 Rx
RS485 A
7
RD_PC
RS-232 Rx
8
TD_PC
RS-232 Ex
9
Ex+
RS-485 Ex
Connection
Connect with USB interface devices or U disks
Port
Function
This interface can be connected with USB keyboard, mouse and printers,
and the U disk can be used for user’s configuration uploading/ downloading
as well as data storage.
Connection
With a standard RJ45 interface cable connected to the Ethernet device.
Port
Function
The port can be used for upload/download of HMI configuration, setting of system parameters and online simulations of configurations. It can connect multiple HMIs via the Ethernet to form an HMI network. Furthermore, it can implement communications between HMI and PLC via the Ethernet, as well as communications with a PC via the Ethernet port.
Connection
USB Slave port can be connected with a PC
Port
Function
The port is only used to download user configuration program to the HMI and to set HMI system parameters.
1. Installation Note
2. Installation Description
Please take shielding measures in the following places:
Places that exist electrostatic
or other kinds of noise
Places of strong
electromagnetic
Places that may be exposed
to rays
Places near the power
Please do not use in the following places:
Places direct in sunlight  Surrounding temperature and humidity beyond
the specifications
Places of temperature change sharply and
easily cause condensation
Places that exist corrosive gas and combustible
gas
Places of much dust, dirt, salt and iron powder  Places that will be splashed water, oil and drugs
3. External Interface
GMTCNT GOP43-070ET/ETE
Human Machine Interface
Installation Instruction
4. Operation Mode
1.1 Environmental Requirement
Please make sure that AC power, PLC output modules, starters, relays and other types of electrical interface device are far away from the back of this product.
1.2 Power Requirement
Input voltage: 1228VDC. Particularly note that there must be enough distance between this product and
converters or switch mode power supply. Make sure that the input and output cables of that kind equipment are shield cable and the shielding network is connected with the ground.
Make sure that the DC power and AC power is isolated.  Do not use common power with perceptual load or input circuit of the controller.
An Internal fuse will prevent damage for over voltage condition, however
it isn’t guaranteed the internal electronic components are not damaged.
Chassis ground must be used.
2.1 Dimensional Drawing
To seal to NEMA-4 specifications, all supplied mounting clamps must be
used and panel cannot flex more than 0.010"
Do not over-tighten mounting clamps!
2.3 Power Connections
Before connecting the power, please make sure all local and national electrical standards are met. For power cables, please select cables with their dielectric strength values and current values in compliance with the safety specifications.
First find the power terminal at the back of the product and loosen the screw according to counterclockwise, then insert the power cables and tighten the screw up.
Connect positive DC line to the ‘+24V’ terminal and the DC ground to the ‘0V’ terminal.
3.1 USB SLAVE
3.2 COM0&COM2
Pin assignment of the 9-pin male, D-SUB, COM0.This port is used To connect the MT4414TE to controller with RS-232/485/422 port. Note: RS232/485/422 communication functions are supported by COM0.
COM2 supports RS232 communication function.
2.2 Fixed Screw Installation Instructions
Put the unit through the panel cut out. Slide the clamps into the 4 holes provided around the case. Tighten the clamping screws in an even pattern until the unit is secured in the panel.
3.3 USB HOST
3.4 Ethernet (MT4434TE Support)
Ethernet interface can adaptive 10 M/ 100 M.
4.1 Instructions for entering Operation Mode selection window
Press and hold the touch panel before power on HMI,then power on HMI.Release your help after HMI enter operation mode selection window,then select the operation mode.If no any operation in 20s after entering operation mode selection window,HMI will enter touch Calibration mode automatically.
4.2 Descriptions of functions in Operation Mode selection window
After entering operation mode selection window,it will popup a menu.Follows are the
descriptions of the functions in the menu:
Loading...
+ 1 hidden pages