D5000 - D5200 Series
INSTRUCTION MANUAL
INSTRUCTION MANUAL
D5D5000 000 -- D5200 SERIESD5200 SERIES
DINDIN--RAIL, POWER BUS,RAIL, POWER BUS,
TERMINATION BOARD MOUNTING TERMINATION BOARD MOUNTING
INTRINSICALLY SAFE ISOLATORSINTRINSICALLY SAFE ISOLATORS
ANDAND SAFETY RELAYSSAFETY RELAYS
D5000 - D5200 Series - Intrinsically Safe Isolators and Safety Relays ISM0121-1
Index
D5000 - D5200 Intrinsically Safe Isolators and Safety Relays
Mechanical features ......................................................................................................................................................................... 3
Mounting and removing modules from DIN-Rail .............................................................................................................................. 4
Power Bus connector ....................................................................................................................................................................... 6
Mounting modules on Power Bus connector .................................................................................................................................... 8
Ordering information ........................................................................................................................................................................ 8
Removing and mounting Main Case Top Cover .............................................................................................................................. 9
Transparent Cover ......................................................................................................................................................................... 10
Terminal Blocks Connection Data .................................................................................................................................................. 11
Installation and removing modules from Termination Board .......................................................................................................... 12
Mounting Termination Board .......................................................................................................................................................... 14
Mounting and removing Termination Board onto DIN-Rail ............................................................................................................ 14
Termination Boards Characteristic ................................................................................................................................................. 15
Approvals and Certifications .......................................................................................................................................................... 16
Storage ........................................................................................................................................................................................... 16
Disposal ......................................................................................................................................................................................... 16
Maintenance and Repair ................................................................................................................................................................ 16
Installation of electronic equipments in cabinet .............................................................................................................................. 17
Heat dissipation in cabinets ........................................................................................................................................................... 18
Calculation of radiant surfaces in closed cabinets ......................................................................................................................... 19
Placement of Isolators in cabinet ................................................................................................................................................... 20
2
D5000 - D5200 Series - Intrinsically Safe Isolators and Safety Relays
Technology for safety
Mechanical features
Mounting Dimensions (D5000) Dimensions (D5200)
T35 DIN-Rail according to EN50022
with or without Power Bus connector
or on Termination Board
Width 12.5 mm
Depth 123.0 mm
Height 120.0 mm
Width 22.5 mm
Depth 123.0 mm
Height 120.0 mm
Case material Blister packing size (D5000) Blister packing size (D5200)
PA66 - Polyamide (Nylon) 66
Width 24.0 mm
Depth 132.0 mm
Height 138.0 mm
Width 34.0 mm
Depth 132.0 mm
Height 138.0 mm
Side D5000 - D5200
Terminal Blocks
tagging zone
123 mm
Laser engraving on entire enclosure
to provide Intrinsic Safety parameters,
schematic diagrams, connections
and instructions
Front D5000
120 mm
12.5 mm
LEDs for power,
status and fault
indication
Hazardous Area/
Field Side
Terminal Blocks
indicator
Front D5200
120 mm
22.5 mm
LEDs for power,
status and fault
indication
Hazardous Area/
Field Side
Terminal Blocks
indicator
Enclosure Characteristics
High channel density results from
innovative circuit design using
advanced surface mount components.
Plug-in screw terminal blocks to secure
2
terminations up to 2.5 mm
.
Configuration components are easily
accessed by removing side cover.
High packing density
35 mm (Top Hat) DIN-Rail.
Ultra slim 2 channels 12 mm wide DIN-Rail
and Termination Board mounting modules.
Power and fault on bus connectors.
6 mm per channel means
50% space reduction.
Technology for safety
D5000 - D5200 Series - Intrinsically Safe Isolators and Safety Relays
3
Mounting
Mounting and removing modules from DIN-Rail
Fig. 1
Push
to
engage
T35 DIN-Rail
Fig. 2
T35 DIN-Rail
To mount Series D5000-D5200 on 35 mm DIN-Rail,
hook one side of the mounting foot over the rail’s lip and press
the barrier down firmly until fixed (see Fig.1 and Fig.2).
Removing
Fig. 3
Screwdriver
T35 DIN-Rail
To remove a barrier from the mounting rail, insert a blade screwdriver in the mounting foot and lever against the side of the barrier casing
(see Fig.3 and Fig.4).
4
D5000 - D5200 Series - Intrinsically Safe Isolators and Safety Relays
Technology for safety
Fig. 4
Pull the module upwards
and remove from DIN-Rail
T35 DIN-Rail
Fig. 5
T35 DIN-Rail
Fig. 6
T35 DIN-Rail Dimensions (millimeters)
Technology for safety
D5000 - D5200 Series - Intrinsically Safe Isolators and Safety Relays
5
Power Bus connector
Power Supply Voltage 24 Vdc can be applied to the module, by connecting directly the voltage to the plug-in Terminal Block of each module,
or via the Power Bus System. The system consists of standard DIN-Rail modules mounted on optional DIN-Rail Power Bus connectors.
The maximum allowed powering capacity is 8 A. It is always possible to remove modules, without disconnecting the bus connector
which remains attached to the DIN-Rail.
Cumulative Fault Alarm indication is provided on the Power Bus connection.
Power Bus system need the accessories shown below, in order to be operative:
JDFT049: D5000 Power Bus Connector (12mm)
Push
To
engage
T35 DIN-Rail
T35 DIN-Rail
F
Power Supply
and Fault
F
Power Supply
and Fault
Modbus RS485
for diagnostic
only
JDFT050: D5200 Power Bus Connector (22mm)
Push
To
engage
T35 DIN-Rail T35 DIN-Rail
Modbus RS485
for diagnostic
only
6
D5000 - D5200 Series - Intrinsically Safe Isolators and Safety Relays
Technology for safety