9 Index ......................................................................................................................27
GLP German Light Production (V1.25)4
1 Description of Device
1
4
1. Moving Head
2. Carrying handles
3. Base
4. Arm
3
2
5. Up- button
6. Down- button
7. Enter- button
8. Mode- button
9. LED- Display
10. Software-Update
connector
11. Microphone- Intensity
12. DMX- Input
13. DMX- Output
14. Power On/Off
15. Fuse F3,15 A
16. Fan (air inlet)
12
11
10
9
87 65
DMX IN DMX OUT
MaxMin
Mic Sensitive
Serial
number:
MODE EN TER UP DOWN
O
M
D
E
E
R
3
H
S
12
Software Update
D
O
W
N
E
N
T
13
FUSE:
T3.1 5A @2 50V
LAMP:
U
P
1.Ground
2.Data-
3.Data+
U
P
MSD 250W
Power input
14
POWER
210V~
230V~
250V~
50Hz
60Hz
Fuse
FUSE
15
16
GLP German Light Production (V1.25)5
1.1 Safety Instructions
The YYPPOOCC 557755 is a High-Tech Product. To guarantee a smooth
operation, it is necessary to keep following rules.
The manufacturer of this device will not take responsibility of
damages through disregard of the information in this manual.
Warranty adjustments will be canceled.
1. Make sure before putting into operation, that the fan and the air inlets are
clean and not blocked by anything.
2. Attention: Don’t touch the device during the operation. This can cause
injuries or damages.
3. Unplug the YYPPOOCC 557755 from the AC outlet before any service.
4. It is necessary to wait at least 30 minutes after disconnecting the AC before
you open the YYPPOOCC 557755. Please do not touch the bulb of the lamp if you are
not absolutely sure it is cold. -Danger of BURNING-
5. Never look directly into the beam of the lamp. You risk injury of your retina and
blindness.
6. Pay attention of the maximum lamp operation time. You have to change it if
the lamp shows any deformations or damages. The same is with all glass
components, color filters, lenses and mirrors.
7. To allow a secure operation, follow also the Installation guide described in
chapter 2. Operating the YYPPOOCC 557755 without suited safety aids like Safety
cables or clamps/hooks can increase the risk of an accident.
8. The installation should be done by qualified staff only. You need to pay
attention to the common rules of technology that are not explicit mentioned in
this manual.
9. Use only original spare parts. Any structural modification will cancel all
warranty adjustments.
Attention: Laser of class 3R may
injure your retina after a short resi-
LASE RSTRAHLUNG
NICHT IN DEN STRAHL BLICKEN
LASER KLASSE 3R
NACH DIN-EN 60825-1/11:2001
λ
P 5mW; = 635-650 nm
0
dence time even without any optical
instrument. Avoid any direct ex-posure of your eyes!
GLP German Light Production (V1.25)6
2 Preparation and Installation
2.1 Mounting
The YYPPOOCC 557755 is fully operational whether it hangs or is mounted to the wall. It
can also be operated while standing on the floor. Keep a safety distance of 0.5 m
towards any easy inflammable materials (decoration etc.). Install a safety wire that
can hold at least 10 times the weight of the fixture. Never use the carrying handles
for secondary attachment.
Pay attention to the regulations of: BGV C1 (former VBG 70)
and DIN VDE 0711-217. Regulations of show laser BGV B2
(11.2001), E DIN 56912 part 6, DIN-EN 60825 part 1+2.
2.1.1 Clamps
There are two major possibilities to mount the YYPPOOCC 557755 together with
clamps. Camlock system or direct mounting of clamps. In both cases you
have to regard a sufficient stability of the system. For installation
instructions please see also printing on the backside of the case.
a) Camlock System: This system allows you a fast and efficient setup of
clamps. Attach the two camlocks to designated position on the backside
GLP German Light Production (V1.25)7
The installation should be done by qualified staff only.
of the case and close the locks by turning them 90°. Verify the secure fit
of the camlock system. The clamps themselves are directly attached
permanently on the camlocks.
90°
b) Use two clamps direct on the backside of the YYPPOOCC 557755 to mount the
unit on a truss (each two opposite threads max. M10x20).
4x M10x20mm
4x Camlock
2.2 Secure the YYPPOOCC 557755
Regardless of the rigging of the YYPPOOCC 557755 you have to use a stipulated safety
wire. Therefore you have to thread to safety wire through to two provided holes on
the backside of the fixture and connect it with the truss-support. Pay attention to a
safe and proper fastening.
GLP German Light Production (V1.25)8
2.3 Connections
2.3.1 Power supply
230 Volt, 50 Hz,
Connected load 700W <=> 3.1 A (blind current compensation).
or 115V, 60 Hz
Connected load 700W <=> 6.2 A (blind current compensation).
Please see printing on the case for the right Power supply !
2.3.2 DMX
DMX 512 Standard input/output. See also printing on the case for the right
pin assignment.
[+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1
The DMX- Addressing starts at the DMX- Address [001].
2.4 Fuse
The YYPPOOCC 557755 electronic system is protected by a 5x20 mm fuse.
230V / T 5A (EU model) or 115V / T 10A (US model)
Please see the printing on the YYPPOOCC 557755 for more details.
Attention:
• Disconnect AC outlet before changing a fuse!
• Use only the original declared fuse type!
GLP German Light Production (V1.25)9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.