GLP Volks Licht R-G-B Instruction Manual

Page 1
from software version 1.15 (Instruction version 1.7)
Internet:
http://www.glp.de
R
-
G
-
B
Page 2
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
2
Notes:
Page 3
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
3
Table of content
1 Description of Device.............................................................................................. 4
1.1 Safety Instructions ............................................................................................ 5
2 Preparation and Installation ................................................................................... 6
2.1 Mounting ........................................................................................................... 6
2.1.1 Mounting on the floor (upright) ............................................................. 7
2.1.2 Mounting in hanging position (Head down) .......................................... 7
2.1.3 Mounting in a sideway Position............................................................ 7
2.2 Securing the Device .......................................................................................... 8
2.3 Connections ...................................................................................................... 8
2.3.1 Power Supply....................................................................................... 8
2.3.2 DMX ..................................................................................................... 8
3 The Menu Field ........................................................................................................ 9
4 DMX Channel Selection (DMX Protocol) ............................................................. 11
5
5 Maintaining and Cleaning the VVOOLLKKSSLLIICCHHTT ....................................................... 13
5.1 Safety regulations ........................................................................................... 13
5.2 Circumference and Interval (rule-of-thumb) .................................................... 13
6 Technical Specifications ...................................................................................... 14
7 System dimensions (in mm) ................................................................................. 15
8 Index ....................................................................................................................... 16
Page 4
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
4
1 Description of Device
1. Moving head (actively and passively cooled)
2. Arm with various cooling vents
3. LCD-Display/Menu (data entry)
4. Base with various connectors and Camlock mounting system
5. Carrying handle. It is also used to attach the safety cable
6
7
8
9
6. Micro-fuse 5x20mm, T2A
7. DMX- Input (3 pole)
8. DMX- Output (3 pole)
9. Power On-/Off
Page 5
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
5
1.1 Safety Instructions
The VVOOLLKKSSLLIICCHHTT is an advanced technology product. To guarantee smooth operation, it is necessary to follow the following instructions.
The manufacturer of this device will not take responsibility of damages through any disregard of the information in this user manual. Warranty claims will also be cancelled in the event of the system casing being opened.
If the external cable of this lighting is damaged, it should be replaced by the manufacturer or its service agent or a qualified person, to avoid danger.
1. Make sure that before powering up the fixture, the fans and air inlets are clean and not blocked by anything.
2. Before powering up the fixture, ensure that the moving head part of the fixture can rotate unhindered through its full range of movement.
3. A safety distance of at least 0.5 m to any easily flammable material (e.g. decoration material) must be adhered to.
4. Attention! Don’t touch the device during operation. Parts of the fixture can become hot and can cause injuries and / or damages.
5. The system doesn’t contain any user serviceable parts. Opening the fixture will void the manufacturers warranty.
6. Danger of burning. Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture. Pay attention to possible hot parts of the system.
7. Never look directly into the beam of light or one of the LEDs. Never use optical apertures with a distance less than 0.5 m to observe the beam of light. LED Class 2M. Not following these precautions can result in serious injury to your eyes and in particular, your retina.
8.
Attention: LED Class 2M can cause inju
ries of your eyes even
without optical instruments in front of them or within a distance of less than 0.5m and short exposure time.
Avoid direct radiation to your eyes!
Page 6
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
6
9. To ensure proper operation, you must also follow the installation guide described in chapter 2 of this manual. Operating the VVOOLLKKSSLLIICCHHTT without suitable mounting devices can increase the risk of an accident.
10. The VVOOLLKKSSLLIICCHHTT features a unique small and lightweight design with no specific carrying handles. Care needs to be shown when handling the fixture to ensure that no unnecessary damage should occur. Fragile areas include the LCD display and cover on one side arm and the front bezel. Pressure in these areas could result in damages which will not be covered by the standard warranty.
11. Repair-, maintenance- and installation work should only be performed by qualified or GLP certified staff. You need to pay attention to the common rules of technology that are not explicit mentioned in this manual.
12. Use only original spare parts. Any structural modification on the system will terminate all warranty claims.
13. Please keep this instruction manual for future reference.
2 Preparation and Installation
2.1 Mounting
The VVOOLLKKSSLLIICCHHTT is fully operational whether it hangs or is mounted to a wall. It can also be operated while standing on the floor. Keep a safety distance of
0.5 m from any easily inflammable materials (decoration etc.).
Page 7
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
7
Pay attention to the regulations of: BGV C1 (former VBG 70)
and DIN VDE 0711-217.
The installation shall be done by qualified staff only.
For the various mounting positions of the VVOOLLKKSSLLIICCHHTT (standing on the floor, sideways or hanging) different accessories kits are available. Using any required kits, along with the standard mounting connectors on the base of the fixture, will ensure a safe and firm installation.
2.1.1 Mounting on the floor (upright)
The VVOOLLKKSSLLIICCHHTT is equipped with four robust rubber feet. This allows a firm and safe stand on even surfaces.
2.1.2 Mounting in hanging position (Head down)
To operate the VVOOLLKKSSLLIICCHHTT in an hanging position, please use a half­coupler (clamp) which is mounted directly onto the bottom side of the system. It is fixed centrically with a M10 thread bolt (max. length 11 mm).
89
3x M10
(max. length 11mm)
2.1.3 Mounting in a sideway Position
To operate the VVOOLLKKSSLLIICCHHTT in a sidewise position, please use two half-couplers (clamps) which are mounted directly onto the bottom side of the system. They are fixed with two M10 thread bolts (max. length 11 mm).
This technique is necessary to cope with the torque which accrues in this mounting position. In addition it allows a concentrically position between
Page 8
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
8
two truss belts. Never use the "Mounting in hanging position" technique described above to secure the fixture in a sideway position, as the fixtures base can become damaged, and a secure installation cannot be assured.
2.2 Securing the Device
Regardless of the mounting method of the VVOOLLKKSSLLIICCHHTT you'll have to use a secondary safety wire. This safety wire can be attached to the fixture by threading it through one of the two holes provided on the base of the fixture. Ensure that the safety wire is securely fastened through the fixture and the fixtures mounting support. Install a safety wire that can hold at least 10 times the weight of the fixture.
2.3 Connections
2.3.1 Power Supply
~100-240 Volt AC, 50-60 Hz, earth contact type plug, via Powercon Connected load 180 VA (W) <=> T2A (micro-fuse 5x20mm) Please see printing on the case for the right electronic supply!
Disconnect from the mains supply for changing the fuse and use only the above described micro-fuse type.
2.3.2 DMX
USITT DMX-512 Standard input/output in 3 pole connectors. 3 pole: Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+] The DMX- Addressing starts at the DMX- Address [001].
Page 9
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
9
3
The Menu Field
You'll find the illuminated control board on the upper side of the base. It allows you to make all necessary adjustments of the system. The current DMX address will be shown on the top level of the menu. Use the Enter-key to adjust the DMX address or press the Menu-key to reach the next level of the menu where other settings can be made.
Menu Enter
1
DMX S tar t Addr ess
With the
Enter
-
key you reach the main menu. Afterwards you can navigate through the menu with the Up/Down- keys. Push the Enter-key to get in the next menu level or to confirm your settings. Adjust them and set functions ON/OFF with the Up/Down-keys. Confirm and save it with the Enter-key (the display shows OK). Use the Back-key to cancel the entry and to go back to the main menu.
Back DownUP Enter
DMX Start Address
Res et
Specia l
VOLK SLICHT M enü

BACK - ENTER 
Level1 Level 2 Level 3 Level 4 Remark
DMX Start
Address
Define the DMX start address
Special Manual DMX
Manual control of all system functions
Pan
Manual control for Pan (X-movement)
Tilt
Manual control for Tilt (Y-movement)
Speed
Speed adjustment for Pan/Tilt movements see also item below
DOWN - UP
P/T
Manual control for Pan/Tilt macro movement
Color
Wheel
Manual control for the color wheel
Red
Manual control for red
Green
Manual control for green
Blue
Manual control for blue
Special
Manual control for special
Dimmer
Manual control for the dimmer
Shutter
Manual control for the shutter
Contrast
Adjustment for the Display contrast
Default Set
Resetting all functions to original values
Versions
Reads out the current LED dimmer (software) version
Page 10
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
10
Adjust
Key code
xxxx
Use the code for entering the calibration menu (for authorized persons only)
Diagnose
Diagnose functions
Pan Offset
Calibration for Pan-Offset
Tilt Offset
Calibration for Tilt-Offset
Clear
EEPROM
Erase EEPROM memory
P/T Speed
Normal Speed and Fast Speed
Temperatures
Indicates the head and base temperature
Testmode
Performs an automatic self-test
DMX Hold
Defines whether the last DMX signal is stored or the lamp is switched OFF in case of signal interruption
Position
Feedback
Automatically position feedback (correction) for Pan/Tilt movement. ON/OFF
Adjust White
Adjustments for a uniform white color (white balance); only in white-mode
Red
Input for red adjustments
Green
Input for blue adjustments
Blue
Input for green adjustments
DMX Monitor
Indicates the presently received DMX signal per DMX channel
Pan
Instantaneous value for Pan
DOWN - UP
Tilt
Instantaneous value for Tilt
Speed
Instantaneous value for Speed
P/T
Instantaneous value for Pan/Tilt movements
Color
Wheel
Instantaneous value for Colors
Red
Instantaneous value for Red
Green
Instantaneous value for Green
Blue
Instantaneous value for Blue
Special
Instantaneous value for Special
Dimmer
Instantaneous value for the Dimmer
Shutter
Instantaneous value for the Shutter
Live time
Indicates the overall operation time of the system
Display
Adjust the display
Blackout
ON/OFF: Display OFF
Reverse Pan
ON/OFF: Invert Pan movements
Reverse Tilt
ON/OFF: Invert Tilt movements
Reset
RESET and new calibration for all functions
Page 11
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
11
4 DMX Channel Selection (DMX Protocol)
Channel
Function
Time and Value
DMX
HEX %
1) PAN
-
coarse
0 .. 660° 0..255 00..FF 0..100
2) PAN
-
fine
High- Pos ... High- Pos + 2,6° (16 Bit) 0..255 00..FF 0..100
3) Tilt
-
coarse
0 .. 300° 0..255 00..FF 0..100
4) Tilt
-
fine
High- Pos … High- Pos + 1,2° (16 Bit) 0..255 00..F F 0..100
5) Color
Colors adjustable via RGB 0..7 00..07 0..2,5
(fixed)
Color 01 - Red 1) 8..15 08..0F 3..5,5 Color 02 - Amber 1) 16..23 10..17 6..8,5 Color 03 - Warm Yellow 1) 24..31 18..1F 9..12,5
Color 04 - Yellow 1) 32..39 20..27 13..15,5
Color 05 - Green 1) 40..47 28..2F 16..18,5
Color 06 - Turquoise 1) 48..55 30..37 19..21,5
Color 07 - Cyan 1) 56..63 38..3F 22..24,5
Color 08 - Blue 1) 64..71 40..47 25..27,5
Color 09 - Lavender 1) 72..79 48..4F 28..30,5 Color 10 - Mauve 1) 80..87 50..57 31..34,5 Color 11 - Magenta 1) 88..95 58..5F 35..37,5 Color 12 - Pink 1) 96..103 60..67 38..40,5 White - CTO Color temperature
3200K
104..111 68..6F 41..43,5
White Color temperature
5600K
112..119 70..77 44..46,5
White - CTB Color temperature
7200K
120..127 78..7F 47..49,5
Rainbow Effect Stop 2) 128 80 50 Rainbow Effect 3) slow - fast 129..223 81..DF 51..88 Rainbow Effect, random colors slow - fast 224.255 E0..FF 89..100
6) Red
Color mixing system - Red 0 - 100% 0..255 00..FF 0..100
7) Green
Color mixing system - Green 0 - 100% 0..255 00..FF 0..100
8) Blue
Color mixing system - Blue 0 - 100% 0..255 00..FF 0..100
9) Shutter
Shutter closed 0..15 00..0F 0..5,5
Random Pulse effect slow - fast 16..47 10..2F 6..18,5
Up-dimming then Shutter closing
(random patterns)
slow - fast 48..79 30..4F 19..31
Shutter open then down-dimming
(random patterns)
slow - fast 80..111 50..6F 32..43
Up-dimming then down-dimming
(random patterns)
slow - fast 112..143 70..8F 44..56
Strobe effect pause 5s .. 1s 144..199 A0..C7 57..77
Strobe effect, slow - fast 1 Hz .. 10 Hz 200..239 C8..EF 78..94
Strobe effect 4) 25 Hz 240 F0 94,4
Strobe effect 4) 50 Hz 241 F1 94,8 Shutter open 242..255 F3..FF 95..100
10) Dimmer
Dimmer 0 - 100% 0..255 0..FF 0..100
11) Special
RESET
250..255
FA..FF
98..100
12) Move
- No movement
0 0 0
ment
Movement
Size Phase
PAN 1 01..01 01..01 0,5
1 90° 02..03 02..03 1,0
1 180° 04..05 04..05 1,7
Page 12
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
12
Channel
Function
Time and Value
DMX
HEX %
1 270° 06..07 06..07 2,5
PAN 2 08..09 08..09 3,3
2 90° 10..11 0A..0B 4,1
2 180° 12..13 0C..0D 4,9
2 270° 14..15 0E..0F 5,7
PAN 3 16..17 11..11 6,5
3 90° 18..19 12..13 7,3
3 180° 20..21 14..15 8,0
3 270° 22..23 16..17 8,8
PAN 4 24..25 18..19 9,6
4 90° 26..27 1A..1B 10,4
4 180° 28..29 1C..1D 11,2
4 270° 30..31 1E..1F 12
TILT size / phase see also PAN 32..63 20..3F 13..25
PAN / TILT size / phase see also PAN 64..95 40..5F 26..37
PAN / TILT (inverse) size / phase see also PAN 96..127 60..7F 38..50
Circle size / phase see also PAN 128..159 80..9F 51..62
Circle (inverse) size / phase see also PAN 160..191 A0..BF 63..75
Lying eight size / phase see also PAN 192..223 C0..DF 76..87
Random movement size see also PAN 224..255 E0..FF 88..100
13) Speed
This channel is only for the SPEED of the movements not for
Pan/Tilt
0..255 00..FF 0..100
Pan/Tilt
1)
The predefined colors can be used as start colors for the Rainbow effect. First select a desired start
color, then activate the rainbow effect. All
VVOOLLKKSSLLIICCHHT
T
will then begin from that color and execute
the rainbow effect synchronously. Different
VVOOLLKKSSLLIICCHHT
T
can have different start colors but will still execute the rainbow effect synchronously. If you choose a color different from the ones marked with 1) in the tables above the rainbow start-color will be red.
2)
Rainbow-effect Stop will pause this function. After resuming the rainbow-effect will be continued with
the current color.
3)
The Rainbow-effect will run synchronously only if it is started from one of the predefined colors (see
also 1) before).
4)
Attention: Please note that shutter frequencies over 10 Hz are prohibited in some countries. Especially frequencies in the range of 5 - 12 Hz can possibly cause epileptic seizures continuous blink irritation with a latency period of min. 70 ms. Please also refer to the relevant legislation of each country (For Germany for example: BGI 810-4 (Anhang 2) "Sicherheit bei Produktionen und Veranstaltungen - Scheinwerfer").
Page 13
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
13
55
Maintaining and Cleaning the VVOOLLKKSSLLIICCHHTT
The VVOOLLKKSSLLIICCHHTT is a low maintenance fixture. It is only necessary to clean the air inlets and outlets as well as the optical LED lenses from time to time. For safe operation it is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build up on, or within, the fixture. If they do, the fixture's light output will be significantly reduced, and damages to the fixture may occur. Regular cleaning will not only ensure the maximum light output, but will also allow the fixture to operate reliably throughout its entire life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recom­mended. Under no circumstances should alcohol or solvents be used to clean the fixture or its lenses!
5.1 Safety regulations
Disconnect the fixture from the mains power before commencing any
maintenance work!
Wait minimum 15 minutes after removing the power to allow the fixture to cool down.
5.2 Circumference and Interval (rule-of-thumb)
The contamination of the fixture depends on the environment details. Hence no general guidelines can be given. The intervals given below are only suggestions from our practice experience.
Maintenance Task Interval How
Cleaning of LED lenses and
optical system
weekly soft brush /lint-free cloth
Cleaning of fans and air channels monthly vacuum cleaner, airbrush, etc.
Attention:
Never let optical parts come into contact with oil or fat.
Before running the fixture wait until all parts are touch dry.
Never touch lenses with bare fingers.
Page 14
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
14
6 Technical Specifications
Power supply Power consumption
180 VA (Watt)
Power Input
~100-240 V AC, 50-60 Hz (auto sensing input)
Fuse protection
Micro-fuse 5x20 mm, T2A
Operational Parameters Max. Ambient
Temperature
45°C / 113°F (integrated overheating switch)
Mounting Position
Any (see chapter mounting)
Lighting System - Additive Color mixing LED Type
60x Luxeon Rebel High-power- LEDs
Lifetime
50.000 h
21x LEDs blue, 21x LEDs green und 18x LEDs red Wavelength optimized for maximum presentable color space
Optical System
High efficient Collimator cluster Exchangeable optical carrier with 10° light distribution angle (25° optional) Scattering light aperture
Shutter / Dimmer (8 Bit)
Strobe- Effect with variable speed between 1 - 10 flashes per second, Random-Strobe, Pulse­Effects
Continuous Dimmer 0 - 100%
DMX Control
Standard USITT DMX-512, 3 pole XLR; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1. Die DMX- Addressing starts at the DMX channel [001].
Pan/Tilt (8/16 Bit) Pan- movement 660° in min. 2 seconds, with position feedback Tilt- movement 300° in min. 1 seconds, with position feedback Weights and Measures
Width of the base
285 mm
Length of the base
242 mm
height (head vertical)
356 mm
Weight (net)
7,8 kg
Page 15
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
15
7 System dimensions (in mm)
3
5
6
290
268
285
80
242
132
1
2
4
0
7
4
Page 16
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
16
8 Index
B
BGV C1............................................................ 6
C
Circumference ............................................... 13
Cleaning......................................................... 13
D
Description of Device ....................................... 4
DIN VDE 0711-217 .......................................... 6
DMX ................................................................. 8
DMX Protocol ................................................ 11
E
e-mail ............................................................... 1
Enter-key ......................................................... 9
I
Instruction Version ........................................... 1
Internet............................................................. 1
L
LED Class 2M ................................................. 5
M
Maintenance .................................................. 13
Menu Field ....................................................... 9
Micro-fuse ........................................................ 8
Mode-key......................................................... 9
Mounting......................................................... 6
Mounting in hanging Position .......................... 7
Mounting in sidewise Position ......................... 7
Mounting on the Floor ..................................... 7
O
Optical parts ................................................ 13
P
Pan- Movement ............................................. 14
Power Supply ................................................ 8
S
Safety distance ............................................... 6
Safety Instructions .......................................... 5
Secure the Device ......................................... 8
Software Version ............................................. 1
T
Technical Specifications ............................ 14
Tilt- Movement .............................................. 14
U
Up/Down-keys ................................................ 9
V
VBG 70 ........................................................... 6
W
Warranty claims .............................................. 6
Weights and Measures ................................. 14
Page 17
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.7) / from software version 1..15)
17
Loading...