GLP Impression X4 XL Instruction Manual

Instruction Manual
from software version: Field Test
Internet: http://www.glp.de
GLP German Light Products GmbH Field Test Documentation 2
Notes:
GLP German Light Products GmbH Field Test Documentation 3
Table of contents
1 Description of Device.............................................................................................. 4
1.1 Safety Instructions ............................................................................................ 5
2 Preparation and Installation ................................................................................... 6
2.1 Safety information ............................................................................................. 6
2.2 Mounting ................................................................ ........................................... 7
2.2.1 Mounting on the Floor (upright)............................................................ 8
2.2.2 Mounting in hanging position (Head down) (Head down) .................... 9
2.3 Securing the Fixture .......................................................................................... 9
2.4 Connections .................................................................................................... 10
2.4.1 Power Supply..................................................................................... 10
2.4.2 DMX ................................................................................................... 10
3 The Menu Field ...................................................................................................... 10
4 DMX Channel Selection (DMX Protocol) ............................................................. 13
4.1 Normal-Mode (26 DMX channels) .................................................................. 13
4.2 Compress-Mode (14 DMX channels) .............................................................. 15
4.3 High Resolution/Extended-Mode (27 DMX Channels) .................................... 16
5 Maintaining and Cleaning ..................................................................................... 18
5.1 Safety regulations ........................................................................................... 18
5.2 Maintenance and Interval (rule-of-thumb) ....................................................... 18
6 Technical Specifications ...................................................................................... 19
7 Dimensions ............................................................................................................ 20
8 Index ....................................................................................................................... 21
GLP German Light Products GmbH Field Test Documentation 4
1 Description of Device
1. Moving head (actively and passively cooled)
2. Arm with various cooling vents
3. LCD-Display/Menu (data entry)
4. Base with various connectors and Camlock mounting system
5. DMX- Output (5 pin)
6. DMX- Output (3 pin)
7. Micro-fuse: 5 x 20mm, T12A
8. Power Switch
9. Neutrik Powercon (Mains power input)
10. Blank panel (primed for Ethernet)
11. DMX- Input (3 pin)
12. DMX- Input (5 pin)
13. 2x Safety wire points
Note: Only connect one cable to the DMX Input / Output at the same time!
GLP German Light Products GmbH Field Test Documentation 5
1.1 Safety Instructions
The IIMMPPRREESSSSIIOONN XX44XXLL is a High-Tech Product. To guarantee a smooth operation, it is necessary to respect the following rules.
The manufacturer of this device will not take responsibility for damages through any disregard of the information provided in this manual. Warranty claims also will be voided in the case that the fixture housing is opened.
1. Before powering on the fixture, make sure that the fixtures fans and air inlets are clean and not blocked.
2. Ensure that the fixture head can rotate unhindered throughout its complete range of pan and tilt movement. A safety distance of at least 0.5 m must be maintained between the fixture and any easily inflammable material (e.g. decoration material).
3. Attention! Don’t touch the fixture during the operation. This can cause injuries and/or damages.
4. The fixture doesn’t contain any user serviceable parts. Opening the fixture will void all warranties.
5. It is necessary to wait at least 15 minutes after disconnecting the mains power before handling the fixture.. Pay attention to possible hot parts of the fixture. -- Danger of BURNING --
6. Never look directly into the beam of light or into one of the LEDs. Never use optical apertures to observe the beam of light. LED Class 2M. You'll risk serious injury of your eyes and in particular of your retina.
Attention: LED Class 2M can cause injuries of your eyes even without optical instruments in front of them or within a distance of less than 0.5m and short exposure time.
Hence: Avoid direct radiation into your eyes!
7. To ensure safe operation, follow also the Installation guide described in chapter 2. Operating the IIMMPPRREESSSSIIOONN XX44XXLL
without suitable safety aids like Safety cables or clamps/hooks can increase the risk of an accident and must be avoided.
8. Repair, maintenance, and installation work shall be done by qualified or GLP certified staff only. You need to pay attention to the common rules of technology that are not explicitly mentioned in this manual.
9. Use only original GLP spare parts. Any structural modification of the system will terminate all warranty claims.
10. Please keep this instruction manual for future reference.
GLP German Light Products GmbH Field Test Documentation 6
2 Preparation and Installation
2.1 Safety information
The IIMMPPRREESSSSIIOONN XX44XXLL
fixture from GLP is fitted with a number of plano­convex lenses in a highly efficient collimator cluster. This type of lens can act as a strong magnifying glass.
If the rays from a strong light source (such as the sun or another lighting fixture) are directed towards the front of any of these fixtures, then internal damage may occur. In a worst case scenario with a high power light source this can happen very quickly, damaging the fixture internally, potentially melting components or causing an internal fire within seconds.
In order to avoid these possible problems please adhere to the following requirements:
Do not expose the front of a fixture to direct sunlight or any other strong
light sources.
For outdoor applications during daylight make sure that the front face of
any fixture is either shielded or points away from the sun, even when fixtures are not in use.
Do not modify the front glass or lenses of any fixture.
These requirements have to be followed regardless of whether a fixture is powered on or off as the magnifying effect is an optical effect and therefore independent from the (electrical) state of the fixture.
Especially when working with high powered bbeeaamm--lliigghhttss
; extreme caution and
observance of these safety instructions is mandatory.
Should you have any questions about the operation of your fixture then please contact your local GLP office, or their authorized distributor, a list of which can be found at http://www.glp.de.
GLP German Light Products GmbH Field Test Documentation 7
2.2 Mounting
The IIMMPPRREESSSSIIOONN XX44XXLL
is fully operational whether it hangs or is mounted to the wall. It can also be operated while standing on the floor. Keep a safety distance of min. 0.5 m towards any easily inflammable materials (decoration etc.).
Pay attention to the regulations of: BGV C1 (former VBG 70)
and DIN VDE 0711-217.
The installation shall be done by qualified staff only.
For the various mounting positions of the IIMMPPRREESSSSIIOONN XX44XXLL
(standing on the floor, sideways or hanging) different accessories kits are available. Through this a safe and firm installation is assured. You'll find dedicated connectors on the bottom side of the fixture which should be used. In addition the base is marked with a FRONT arrow allowing consistent orientation during installation.