GLP impression rgb 120 rz Instruction Manual

Instruction Manual
from software version 1.00/30 (Instruction version 1.0)
e-mail: service@glp.de
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 2
Notes:
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 3
Table of content
1 Description of Device.............................................................................................. 4
1.1 Safety Instructions ............................................................................................ 5
2 Preparation and Installation ...................................................................................6
2.1 Mounting ...........................................................................................................6
2.1.1 Mounting on the Floor (Upright).............................................................7
2.1.2 Mounting in hanging Position (Head first)..............................................7
2.1.3 Mounting in sidewise Position ............................................................... 8
2.2 Secure the Device.............................................................................................9
2.3 Connections...................................................................................................... 9
2.3.1 Power Supply ........................................................................................ 9
2.3.2 DMX ......................................................................................................9
3 The Menu Field ...................................................................................................... 10
4 DMX Channel Selection (DMX Protocol) .............................................................12
5 Maintaining and Cleaning the IIMMPPRREESSSSIIOONN ....................................................... 17
5.1 Safety regulations ........................................................................................... 17
5.2 Circumference and Interval (rule-of-thumb).................................................... 17
6 Technical Specifications.......................................................................................18
7 Index .......................................................................................................................19
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 4
1 Description of Device
1. Moving head (actively and
passively cooled)
2. Arm with various cooling
vents
3. LCD-Display/Menu (data
entry)
4. Base with various
connectors and Camlock
mounting system
1
2
3
4
5
base side 1
6
base side 2
7 8 9 1010
FUSE T4A
5. Power On/Off
6. DMX- Output (3 pole)
7. DMX- Input (3 pole)
8. Micro-fuse 5x20mm, T5A
9. Mains supply (Powercon)
10. 2x Safety eyes
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 5
1.1 Safety Instructions
The IIMMPPRREESSSSIIOONN is a High-Tech Product. To guarantee a smooth operation, it is necessary to respect the following rules.
The manufacturer of this device will not take responsibility of damages through any disregard of the information in this manual. Warranty claims also will be cancelled in case the system casing is opened.
1. Make sure before putting the system into operation, that the fan and the air
inlets are clean and not blocked by anything.
2. It must be assured that the system-head can rotate unhindered throughout
his complete rotating range. A safety distance of at least 0.5 m to any easily
inflammable material (e.g. decoration material) must be adhered.
3. Attention!
Don’t touch the device during the operation. This can cause
injuries or damages.
4. The system doesn’t contain any maintainable parts. Don’t open it!
5. It is necessary to wait at least 15 minutes after disconnecting the AC before
changing the optical carrier. Pay attention to possibly hot parts of the
system. -- Danger of BURNING --
6. Never look directly into the beam of light or one of the LEDs.
Never use
optical apertures with a distance less than 0.5 m to observe the beam of
light. LED Class 2M.
You'll risk a serious injury of your eyes and in
particular of your retina.
Attention: LED Class 2M can cause injuries of your eyes even without optical instruments in front of them or within a distance of less than 0.5m and short exposure time.
Hence: Avoid direct radiation of your eyes!
7. To allow a secure operation, follow also the Installation guide described in
chapter 2. Operating the IIMMPPRREESSSSIIOONN without suitable safety aids like
Safety cables or clamps/hooks can increase the risk of an accident.
8. Repair-, maintenance- and installation work shall be done by qualified or
GLP certified staff only. You need to pay attention to the common rules of
technology that are not explicit mentioned in this manual.
9. Use only original spare parts. Any structural modification on the system will
terminate all warranty claims.
10. Please keep this instruction manual for later reference.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 6
2 Preparation and Installation
2.1 Mounting
The IIMMPPRREESSSSIIOONN is fully operational whether it hangs or is mounted to the
wall. It can also be operated while standing on the floor. Keep a safety distance
of 0.5 m towards any easily inflammable materials (decoration etc.).
Pay attention to the regulations of: BGV C1 (former VBG 70)
and DIN VDE 0711-217.
The installation shall be done by qualified staff only.
For the various mounting positions of the IIMMPPRREESSSSIIOONN (standing on the floor,
sideways or hanging) different accessories kits are available. Through this a
safe and firm installation is assured. You'll find special connectors on the
bottom side of the system which are put to use here. In addition the front side of
the system is marked with (FRONT) as this is important for a even orientation
during installation.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 7
1x M10
(length max.16mm)
2x Camlock quick release fasteners
front side of the fixture
2.1.1 Mounting on the Floor (Upright)
To operate the IIMMPPRREESSSSIIOONN in an upright position, please use the
dedicated tripod which is mounted to the bottom side of the system. It is
fixed with fasteners called Camlock quick-release connectors. Turn the
two fasteners both 90° to lock them. Do the opposite to release them
again. On both sides you'll find eyelets to pull though a fixing strap. This
allows an additional bracing of the system during the upright operation.
2.1.2 Mounting in hanging Position (Head first)
To operate the IIMMPPRREESSSSIIOONN in an hanging position, please use a half-
coupler (clamp) which is mounted directly to the bottom side of the
system. It is fixed centrically with a M10x16 mm thread bolt.
2x Camlock
2x Eyelets
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 8
M10x16
2.1.3 Mounting in sidewise Position
To operate the IIMMPPRREESSSSIIOONN in a sidewise position, please use an
addition mounting bar. Also this is fixed by two Camlock quick-release
connectors. Two half-couplers (clamps) are now used to mount the
system to a standard truss bar. This technique is necessary to cope with
the torque which accrues in this mounting position. In addition it allows a
concentrically position between two truss belts. Never use the "Mounting
in hanging Position" technique described above to fasten the system in
the sidewise position. A safe and sound installation can not be assured
in this way. This can also damage the system base.
2x 90°
Half-coupler (clamp) 1 Half-coupler (clamp) 2
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 9
without mounting bar
2.2 Secure the Device
Regardless of the mounting method of the IIMMPPRREESSSSIIOONN you'll have to use a
stipulated safety wire. Therefore you have to pull the safety wire through to two
provided holes on the bottom side of the system and connect it with the truss-
support. Pay attention to a safe and proper fastening. Install a safety wire that
can hold at least 10 times the weight of the fixture. Never use the carrying
handles for this purpose.
2.3 Connections
2.3.1 Power Supply
~100-240 Volt AC, 50-60 Hz, earth contact type plug - Powercon
Connected load 350 VA (W) <=> T5A (micro-fuse 5x20mm)
Please see printing on the case for the right electronic supply!
Disconnect from the mains supply for changing the fuse and use
only the above described micro-fuse type.
2.3.2 DMX
USITT DMX-512 Standard input/output in 3 pole connectors.
3 pole: Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+]
The DMX- Addressing starts at the DMX- Address [001].
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 10
3 The Menu Field
You’ll find the control board on the side part of the arm. It allows you to make all necessary adjustments of the IIMMPPRREESSSSIIOONN.. With the Mode-key you get into the main menu. Afterwards you can navigate through the menu with the Up/Down-keys. Push the Enter-key to get in the next menu level or to confirm your settings. Make them and set functions ON/OFF with the Up/Down-keys. Confirm and save it with the Enter-key (the display shows OK). Push the Mode-key to cancel the entry and go back to the main menu.
Mode Down
Enter Up
Å MODE - ENTER Æ
Level1 Level 2 Level 3 Level 4 Remark
DMX Start Address 001
Define the DMX start address
Special Manual DMX
Manual control of all system functions
Pan
Manual control for Pan (X-movement)
Speed Movements
Speed adjustment for Pan/Tilt movements Æ see also item below
Pan/Tilt Movements
Manual control for Pan/Tilt movement
Special
Activate the White- or Full-Power Mode; see also DMX table
White Temperature
Manual control for Color temperature
Dimmer
Manual control for Dimmer
Shutter
Manual control for Shutter
Blue
Manual control for blue
Green
Manual control for green
Red
Manual control for red
Color Wheel
Manual control for the color wheel
Zoom
Manual control for zoom
Tilt
Manual control for Tilt (Y-movement)
Display Contrast
Adjustment for the Display contrast
Default Set
Resetting all functions to original values
Set Dimmer Frequency
Changes PMW frequency between 600Hz and 1200Hz
LED Dimmer Version
Reads out the current LED dimmer (software) version
Impression Version
Reads out the current CPU software version
Adjust
Key code xxxx
Use the code for entering the calibration menu (for authorized persons only)
Pan Offset
Calibration for Pan-Offset
Å DOWN - UP Æ
Tilt Offset
Calibration for Tilt-Offset
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 11
Clear EEPROM
Erase EEPROM memory
Diagnose
Diagnose functions
Pos Feed Pan Delta
Internal data and function diagnose
Anz Ti0­Int-Err
Internal data and function diagnose
PFC Voltage
Show the present PFC voltage
Pos Feed Tilt Delta
Internal data and function diagnose
Temperature Arm
Indicates the arm temperature
Temperature Head
Indicates the head temperature
PAN/TILT Motor Power
Switches power for Pan/Tilt ON or OFF (disconnected from power)
PAN/TILT Silent Mode
Reduces maximum speed for Pan/Tilt
DMX Hold
Defines whether the last DMX signal is stored or the lamp is switched OFF in case of signal interruption
Position Feedback
Automatically position feedback (correction) for Pan/Tilt movement
White Adjust
Adjustments for a uniform white color (white balance); only in white-mode
Red
Input for red adjustments
Blue
Input for blue adjustments
Green
Input for green adjustments
Å DOWN - UP Æ
Set DMX Image
Stores the Scene currently sent to the unit
DMX input Monitor
Indicates the presently received DMX signal per DMX channel
Pan
Instantaneous value for Pan
Speed Movements
Speed adjustment for Pan/Tilt movements Æ see item below
Pan/Tilt Movements
Instantaneous value for Pan/Tilt movements
Special
Instantaneous value for Special
White Temperature
Adjustment of the color temperature for WHITE
Dimmer
Instantaneous value for Dimmer
Shutter
Instantaneous value for Shutter
Blue
Instantaneous value for Blue
Green
Instantaneous value for Green
Red
Instantaneous value for Red
Zoom
Instantaneous value for Zoom
Color Wheel
Instantaneous value for Color Mixing unit
Tilt
Instantaneous value for Tilt movement
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 12
Self test
Performs an automatic self-test
Live time
Indicates the overall operation time of the system
Display
Adjust the display
Blackout
ON/OFF: Display OFF
Select DMX Mode
Please select the desired DMX Mode
Compressed
Fixture works in "Compressed" mode Æ see also section 4 below
Normal
Fixture works in "Normal" mode Æ see also section 4 below
High­Resolution
Fixture works in "High Resolution" mode Æ see also section 4 below
White Mode
ON/OFF: Adjustments for white-balance are activated
Reverse Pan
ON/OFF: Invert Pan movements
Å DOWN - UP Æ
Reverse Tilt
ON/OFF: Invert Tilt movements
Reset
RESET and new calibration for all functions
4 DMX Channel Selection (DMX Protocol)
Normal-Mode 15 DMX channels
Channel Function Time and Value DMX HEX %
1) PAN­ coarse
0 .. 660° 3,2 s 0..255 00..FF 0..100
2) PAN-fine High- Pos ... High- Pos + 2,6° (16 Bit) 0..255 00..FF 0..100
3) Tilt­ coarse
0 .. 300° 1,5 s 0..255 00..FF 0..100
4) Tilt-fine High- Pos … High- Pos + 1,2° (16 Bit) 0..255 00..FF 0..100
5) Color Colors adjustable via RGB 0..7 00..07 0..2,5 (fixed) Color 01 - Red 1) 8..15 08..0F 3..5,5
Color 02 - Amber 1) 16..23 10..17 6..8,5 Color 03 - Warm Yellow 1) 24..31 18..1F 9..12,5
Color 04 - Yellow 1) 32..39 20..27 13..15,5 Color 05 - Green 1) 40..47 28..2F 16..18,5 Color 06 - Turquoise 1) 48..55 30..37 19..21,5 Color 07 - Cyan 1) 56..63 38..3F 22..24,5 Color 08 - Blue 1) 64..71 40..47 25..27,5
Color 09 - Lavender 1) 72..79 48..4F 28..30,5 Color 10 - Mauve 1) 80..87 50..57 31..34,5 Color 11 - Magenta 1) 88..95 58..5F 35..37,5 Color 12 - Pink 1) 96..103 60..67 38..40,5 White - CTO Color temperature
3200K
104..111 68..6F 41..43,5
White Color temperature
5600K
112..119 70..77 44..46,5
White - CTB Color temperature
7200K
120..127 78..7F 47..49,5
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 13
Channel Function Time and Value DMX HEX %
Rainbow Effect Stop 2) 128 80 50 Rainbow Effect
3)
slow - fast 129..223 81..DF 51..88
Rainbow Effect, random colors slow - fast 224.255 E=..FF 89..100
6) Red Color mixing system - Red 0 - 100% 0..255 00..FF 0..100
7) Green Color mixing system - Green 0 - 100% 0..255 00..FF 0..100
8) Blue Color mixing system - Blue 0 - 100% 0..255 00..FF 0..100
9) Shutter Shutter closed 0..15 00..0F 0..5,5 Random Pulse effect slow - fast 16..47 10..2F 6..18,5 Up-dimming then Shutter closing
(random patterns)
slow - fast 48..79 30..4F 19..31
Shutter open then down-dimming
(random patterns)
slow - fast 80..111 50..6F 32..43
Up-dimming then down-dimming
(random patterns)
slow - fast 112..143 70..8F 44..56
Strobe effect pause 5s .. 1s 144..199 A0..C7 57..77 Strobe effect, slow - fast 1 Hz .. 10 Hz 200..239 C8..EF 78..94
Shutter open 240..255 F0..FF 95..100
10) Dimmer Dimmer 0 - 100% 0..255 0..FF 0..100
11) Color No color temperature correction 0..6 0..06 0..2 temperature Continuous color temperature
correction between 3200k - 7200k
Applicable only for White color
5)
7..255 07..FF 3..100
12) Special Max. Power-Mode 4) Max. light output without
white balance
0..15 0..0F 0..5,5
White-Mode
4)
White balance used 16..31 10..1F 6..12,5
Fan min. as long as temp. < 90°C 224..229 E0..E5 88..89,5 RESET (Normal Mode) 250..255 FA..FF 98..100
13) Move- No movement 0 00 0 ment Movement Size Phase PAN 1 01..01 01..01 0,5 1 90° 02..03 02..03 1,0 1 180° 04..05 04..05 1,7 1 270° 06..07 06..07 2,5 PAN 2 08..09 08..09 3,3 2 90° 10..11 0A..0B 4,1 2 180° 12..13 0C..0D 4,9 2 270° 14..15 0E..0F 5,7 PAN 3 16..17 11..11 6,5 3 90° 18..19 12..13 7,3 3 180° 20..21 14..15 8,0 3 270° 22..23 16..17 8,8 PAN 4 24..25 18..19 9,6 4 90° 26..27 1A..1B 10,4 4 180° 28..29 1C..1D 11,2 4 270° 30..31 1E..1F 12 TILT size / phase see also PAN 32..63 20..3F 13..25 PAN / TILT size / phase see also PAN 64..95 40..5F 26..37 PAN / TILT (inverse) size / phase see also PAN 96..127 60..7F 38..50 Circle size / phase see also PAN 128..159 80..9F 51..62 Circle (inverse) size / phase see also PAN 160..191 A0..BF 63..75 Lying eight size / phase see also PAN 192..223 C0..DF 76..87 Random movement size see also PAN 224..255 E0..FF 88..100
14) Speed Pan/Tilt relative movement 0..15 00..0F 0..6
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 14
Channel Function Time and Value DMX HEX %
Pan/Tilt Pan/Tilt slow – fast
Use this channel 14) also for the speed
of the movements (channel 13).
Pan Min. 660° = 200s Pan Max. 660° = 3,2s Tilt Min. 300° = 110s Tilt Max. 300° = 1,5s
16..255 10..FF 7..100
15) Zoom Spot - Flood 10° - 26° 0…255 00…FF 0…100
4)
Max. Power-Mode vs. White-Mode
The IIMMPPRREESSSSIIOONN can regard the white-balance adjustments for each individual color setting.
Whether the White-Mode is used with RGB can be selected in the Normal DMX-Mode during
operation with the Special DMX channel. If the Special channel is set to a value between DMX 0..15,
the White-Mode is not used and the RGB goes for the maximum light output. If the Special channel is
set to a value between DMX 16..31, the white balance is used for the RGB output.
Since there is no Special DMX channel in the Compress DMX-Mode, the possibility exists to likewise
select these settings also in the display menu. Is the White-Mode set to “ON”, the white-balance is
activated. If the White-Mode is set to “OFF”, the RGB goes for the maximum light output (Max. Power-
Mode).
5)
The continuous color temperature correction is applicable only for the White color i.e. if this function
is selected (DMX
006) the
IImmpprreessssiioon
n
will change the color to white immediately and will then be
adjustable in the color temperature in a range between 3200K and 7200K. Hence a color correction for
others than white is not intended.
Compress-Mode 11 DMX channels
Channel Function Time and Value DMX HEX %
1) PAN­ coarse
0 .. 660° 3,2 s 0..255 00..FF 0..100
2) PAN-fine High- Pos ... High- Pos + 2,6° (16 Bit) 0..255 00..FF 0..100
3) Tilt­ coarse
0 .. 300° 1,5 s 0..255 00..FF 0..100
4) Tilt-fine High- Pos … High- Pos + 1,2° (16 Bit) 0..255 00..FF 0..100
5) Color Colors adjustable via RGB 0..7 00..07 0..2,5 (fixed) Color 01 - Red 1) 8..15 08..0F 3..5,5
Color 02 - Amber 1) 16..23 10..17 6..8,5 Color 03 - Warm Yellow 1) 24..31 18..1F 9..12,5
Color 04 - Yellow 1) 32..39 20..27 13..15,5
Color 05 - Green 1) 40..47 28..2F 16..18,5
Color 06 - Turquoise 1) 48..55 30..37 19..21,5
Color 07 - Cyan 1) 56..63 38..3F 22..24,5
Color 08 - Blue 1) 64..71 40..47 25..27,5
Color 09 - Lavender 1) 72..79 48..4F 28..30,5 Color 10 - Mauve 1) 80..87 50..57 31..34,5 Color 11 - Magenta 1) 88..95 58..5F 35..37,5 Color 12 - Pink 1) 96..103 60..67 38..40,5 White - CTO Color temperature
3200K
104..111 68..6F 41..43,5
White Color temperature
5600K
112..119 70..77 44..46,5
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 15
Channel Function Time and Value DMX HEX %
White - CTB Color temperature
7200K
120..127 78..7F 47..49,5
Rainbow Effect Stop 2) 128 80 50 Rainbow Effect
3)
slow - fast 129..223 81..DF 51..88
Rainbow Effect, random colors slow - fast 224.255 E0..FF 89..100
6) Red Color mixing system - Red 0 - 100% 0..255 00..FF 0..100
7) Green Color mixing system - Green 0 - 100% 0..255 00..FF 0..100
8) Blue Color mixing system - Blue 0 - 100% 0..255 00..FF 0..100
9) Shutter Shutter closed 0..15 00..0F 0..5,5 Random Pulse effect slow - fast 16..47 10..2F 6..18,5 Up-dimming then Shutter closing
(random patterns)
slow - fast 48..79 30..4F 19..31,5
Shutter open then down-dimming
(random patterns)
slow - fast 80..111 50..6F 32..43
Up-dimming then down-dimming
(random patterns)
slow - fast 112..143 70..8F 44..56
Strobe effect pause 5s .. 1s 144..199 A0..C7 57..77 Strobe effect, slow - fast 1 Hz .. 10 Hz 200..239 C8..EF 78..94 Shutter open 240...249 F0..F9 95..97,5 RESET Min. 3 Sec. 250 FA 98
Shutter open 251..255 FB..FF 99..100
10) Dimmer Dimmer 0 - 100% 0..255 0..FF 0..100
11) Zoom Spot - Flood 10° - 26° 0…255 00…FF 0…100
High Resolution (Extended) -Mode 14 DMX Channels
Channel Function Time and Value DMX HEX %
1) PAN­ coarse
0 .. 660° 3,2 s 0..255 00..FF 0..100
2) PAN-fine High- Pos ... High- Pos + 2,6° (16 Bit) 0..255 00..FF 0..100
3) Tilt­ coarse
0 .. 300° 1,5 s 0..255 00..FF 0..100
4) Tilt-fine High- Pos … High- Pos + 1,2° (16 Bit) 0..255 00..FF 0..100
5) Red­ coarse
Color mixing system – Red 0 - 100% 0..255 00..FF 0..100
6) Red-fine Color mixing system – Red-Low 0..255 00..FF 0..100
7) Green­ coarse
Color mixing system – Green 0 - 100% 0..255 00..FF 0..100
8) Green­ fine
Color mixing system – Green-Low 0..255 00..FF 0..100
9) Blue­ coarse
Color mixing system – Blue 0 - 100% 0..255 00..FF 0..100
10) Blue-fine Color mixing system – Blue-Low 0..255 00..FF 0..100
11) Shutter Shutter closed 0..15 00..0F 0..5,5 Random Pulse effect slow - fast 16..47 10..2F 6..18,5 Up-dimming then Shutter closing
(random patterns)
slow - fast 48..79 30..4F 19..31,5
Shutter open then down-dimming
(random patterns)
slow - fast 80..111 50..6F 32..43
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 16
Channel Function Time and Value DMX HEX %
Up-dimming then down-dimming
(random patterns)
slow - fast 112..143 70..8F 44..56
Strobe effect pause 5s to 1s 144..199 A0..C7 57..77 Strobe effect, slow - fast 1 Hz .. 10 Hz 200..239 C8..EF 78..94 Shutter open 240...249 F0..F9 95..97,5 RESET Min. 3 Sec. 250 FA 98
Shutter open 251..255 FB..FF 99..100
12) Dimmer­ coarse
Dimmer 0 - 100% 0..255 0..FF 0..100
13) Dimmer­ fine
Dimmer - Low 0..255 0..FF 0..100
14) Zoom Spot - Flood 10° - 26° 0…255 00…FF 0…100
1)
The predefined colors can be used as start-colors for the Rainbow effect. Please select first a
desired start-color before you activate the rainbow effect. All
IImmpprreessssiioonns
s
will afterwards start from
that color and will execute the rainbow effect synchronously. Different
IImmpprreessssiioonns
s
can certainly
have different start-colors but will still execute the rainbow effect synchronously. If you choose a color
different from the once marked with 1) in the tables above the rainbow start-color will be red.
2)
Rainbow-effect Stop will pause this function. After resuming the rainbow-effect will be continued with
the current color.
3)
The Rainbow-effect will run synchronously only if it will be started going out from one of the
predefined colors (see also
1)
before).
Locking and unlocking the Control Panel
Please lock and unlock the control panel by pressing the menu keys MODE & ENTER & UP at the
same time.
Additional features during switching-ON the system
a) 1200Hz Mode (Hold down the UP- button during power ON)
After switching ON the system the LEDs will be operated with a Pulse Width Modulation
(PWM) of 1200Hz.
In addition all standard setting will be loaded (DMX start address [001], Normal Mode).
b) 600Hz Mode (Hold down the DOWN- button during power ON)
After switching ON the system the LEDs will be operated with a Pulse Width Modulation
(PWM) of 600Hz.
In addition all standard setting will be loaded (DMX start address [001], Normal Mode).
c) Standard Mode (Hold down the ENTER- button during power ON)
After switching ON the system the DMX start address will be set to [001]. All other setting
remain unchanged.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 17
Additional Display Indications
As a default you'll find the following additional information in the first row of the LCD display:
XX/X/XX
06 = 600Hz / 12 = 1200Hz
N = Normal Mode / C = Compressed Mode / H = High Res. Mode
N = Tilt normal / I = Tilt inverted
N = Pan normal / I = Pan inverted
55
Maintaining and Cleaning the IIMMPPRREESSSSIIOONN
The IIMMPPRREESSSSIIOONN is a system of very low maintenance. It is only necessary to clean
the air in- and outlets as well as the optical LED lenses from time to time. For a safe
operation it is absolutely essential that the fixture is kept clean and that dust, dirt and
smoke-fluid residues must not built up on or within the fixture. Otherwise the fixture's
light-output will be significantly reduced or damages can occur. Regular cleaning will
not only ensure the maximum light-output, but will also allow the fixture to operate
reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recom-
mended, under no circumstances should alcohol or solvents be used!
5.1 Safety regulations
Pull out the main plug!
Wait min. 15 minutes after the last operation to cool down the fixture.
5.2 Circumference and Interval (rule-of-thumb)
The contamination of the fixture depends on the environment details. Hence no
general guidelines can be given. The intervals given below are only suggestions
from our practice experience.
Position Interval In this way
LED reflector and optical system weekly soft brush /lint-free cloth
Fan and air channel monthly vacuum cleaner, airbrush, etc.
Attention:
Never let optical parts come into contact with oil or fat.
Before running the fixture wait until all parts are dried up.
Never tough lenses with bare fingers.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 18
6 Technical Specifications
Power supply Power consumption
350 VA (Watt)
Power Input
~100-240 V AC, 50-60 Hz (wide range input)
Fuse protection
Micro-fuse 5x20 mm, T5A
Operational Parameters Max. Ambient
Temperature
45°C (integrated overheating switch)
Mounting Position
Any (see chapter mounting)
Lighting System - Additive Color mixing LED Type
120x Rebel High-power- LEDs
Lifetime
100.000 h
42x green LEDs, 36x blue LEDs, 42x red LEDs Wavelength optimized for maximum presentable color space
Optical System
High efficient Collimator cluster Fixed optical mount with an angel of reflected beam between 10° - 26°
Shutter / Dimmer (8/16 Bit)
Strobe- Effect with variable speed between 1 - 10 flashes per second, Random-Strobe, Pulse­Effects
Continuous Dimmer 0 - 100%
DMX Control
Standard USITT DMX-512, 3 pole XLR; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1. Die DMX- Addressing starts at the DMX channel [001].
Pan / Tilt (8/16 Bit) Pan- movement 660° in min. 3,2 seconds (Position Feedback) Tilt- movement 300° in min. 1,5 seconds (Position Feedback)
Weights and Measures Width of the base
340 mm
Length of the base
145 mm
height (head vertical)
370 mm
Weight (net)
8.0 kg
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 19
7 Index
A
Angel of reflected beam ........................... 20
B
BGV C1.......................................................... 7
C
Camlock......................................................... 8
Circumference.............................................. 18
Cleaning....................................................... 18
Compress-Mode
................................... 15, 16
D
Danger of BURNING..................................... 6
Description of Device..................................... 5
DIN VDE 0711-217 ........................................ 7
DMX ............................................................. 10
E
e-mail............................................................. 1
Enter-key ................................................... 11
Eyelets........................................................... 8
H
Half-couplers (clamps) ................................... 9
I
Instruction Version ......................................... 1
Internet........................................................... 2
L
LED Class 2M ............................................... 6
M
Maintenance ................................................ 18
Max. Power-Mode
....................................... 15
Menu Field................................................... 11
Micro-fuse.................................................... 10
Mode-key ................................................... 11
Mounting....................................................... 7
Mounting in hanging Position ......................... 8
Mounting in sidewise Position ........................ 9
Mounting on the Floor .................................... 8
N
Normal-Mode .............................................. 13
O
Optical parts............................................... 19
P
Pan- Movement............................................ 20
Power Supply ............................................. 10
Powercon....................................................... 5
R
Rebel High-power- LEDs.......................... 20
S
Safety distance............................................... 7
Safety Instructions.......................................... 6
Secure the Device ...................................... 10
Software Version............................................ 1
T
Technical Specifications ........................... 20
Tilt- Movement ............................................. 20
U
Up/Down-keys........................................... 11
V
VBG 70 .......................................................... 7
W
Warranty claims ............................................. 6
Weights and Measures ................................ 20
White-Mode
................................................. 15
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH (Instruction version 1.0) / from software version 1.00/30) 20
Loading...