The marks ‘GLP’ and ‘German Light Products’ are trademarks registered as the property of
German Light Products GmbH in Germany, in the United States of America and in other
countries.
The information contained in this document is subject to change without notice. German Light
Products GmbH and all affiliated companies disclaim liability for any injury, damage, direct or
indirect loss, consequential or economic loss or any other loss occasioned by the use of,
inability to use or reliance on the information contained in this document.
German Light Products GmbH (GLP), Industriestrasse 2, 76307 Karlsbad, Germany
info@germanlightproducts.com
Tel (USA): +1.818.767.8899
www.germanlightproducts.com
Tel (Germany): +49 (7248) 927 1955
www.glp.de
German Light Products
1. Safety
Key to symbols
The following symbols are used in this manual:
Warning! Safety hazard.
Risk of severe injury or
death.
Warning! See user
manual for important
safety information.
Warning! Risk of eye
injury.
Warning! Hazardous voltage.
Risk of lethal or severe
electric shock.
Warning! Fire hazard.
General safety information
Read this section carefully before installing or using the product. If you have any
doubts or questions about how to use the product safely, contact your GLP supplier for
assistance. Your GLP supplier will be happy to help.
The impression FR1 and this user manual are intended for use by experienced
professionals with the knowledge and skills to set up, operate, and maintain highpowered, remotely controlled lighting equipment safely and efficiently. These
operations require expertise that may not be provided in this manual.
• Respect all warnings and directions given in this user manual and on the product.
Read this manual and familiarize yourself with the safety precautions it contains
before installing or using the product. The manufacturer will take no responsibility for
damages or harm resulting from disregard for the information in this manual.
• Check the GLP website at www.glp.de and make sure that you have the latest
version of this user manual. Check also that the software version indicated on page 2
of the user manual matches the version installed in the product. You can download
the correct version of this user manual if necessary.
• Make the user manual available to all installers and operators and save the manual
for future reference.
• If you have questions about the safe operation of the impression FR1, please contact
an authorized GLP distributor (see list of distributors at www.glp.de).
impression FR1 User Manual 3
www.glp.de
• Use the product only as directed in this user manual. Observe all markings in this user
manual and on the product.
• Refer any service operation not described in this manual and refer all repairs to a
technician authorized by GLP.
• The light source in this product must not be changed by the end user.
• Read and follow the user documentation for all additional equipment.
Electrical safety
• Do not allow the product to come into contact with water or moisture.
• Use only a source of AC mains power that complies with local building and electrical
codes and has both overload and ground fault (earth fault) protection.
• Ensure that the product is electrically connected to ground (earth).
• Disconnect the product from AC mains power before carrying out any installation or
maintenance work and when the product is not in use.
• Neutrik PowerCON connectors are not suitable for hot-plugging, so ensure that the
power outlets or power switches on the circuits used to supply the product with power
are located near the product and are easily accessible so that the product can
easily be disconnected from power.
• Disconnect the product from power immediately if the power plug or any seal, cover,
cable, or other component is damaged, defective, deformed, wet or showing signs
of overheating. Do not reapply power until the product has been repaired and made
safe by a technician authorized by GLP.
• Before using the product, check that all power distribution equipment and cables are
in perfect condition and rated for the electrical requirements of all connected
devices.
• Use only Neutrik PowerCON cable connectors for input and throughput at the
product’s power connectors.
• Use minimum 14 AWG or 1.5 mm2 power input and relay cables that are minimum
16 A rated and temperature-rated to suit the application. In the USA and Canada the
cables must be UL-listed, type SJT or equivalent. In the EU the cables must be type
H05VV-F or equivalent.
• Do not connect devices to power in a chain using their power throughput connectors
if the total maximum current draw of all the devices in the chain when added
together will exceed the current rating of any cable or connector used at any point
in the chain. The supplied power input cable is rated as follows:
- US power cable: 16 A, 14 AWG, UL listed, E304117, SJT, 4.9 ft.
- EU power cable: 16 A, 1.5 mm², H05VV-F, 1.5 m
4 impression FR1
User Manual
German Light Products
Do not connect more than sixteen (16) impression FR1 fixtures to power in a chain at
100-120 V, 60 Hz.
Do not connect more than thirty-two (32) impression FR1 fixtures to power in a chain
at 200-240 V, 50 Hz.
• The voltage and frequency at the Mains Out socket are the same as the voltage and
frequency applied to the Mains In socket. Only connect devices to the Mains Out
socket that accept this voltage and frequency.
• If a fuse blows, replace it with one of the original type and rating only. If new fuses
blow, disconnect the product from power and send it to a technician authorized by
GLP for repair.
Fire safety and protection from burns
• Do not operate the product if the ambient temperature (Ta) exceeds 45° C (115° F).
• The surface of the product’s casing can reach up to 55° C (131° F) during operation.
Avoid contact by persons and materials. Do not install the product in a location
where there is a risk of accidental contact. Allow the product to cool for at least 10
minutes before handling
• Keep the product well away from flammable materials.
• Keep all combustible materials (e.g. fabric, wood, paper) at least 100 mm (4 in.)
away from the product.
• Ensure that there is free and unobstructed airflow around the product. Provide a
minimum clearance of 100 mm (4 in.) around fans and air vents.
• Do not illuminate surfaces within 500 mm (19.7 in.) of the product.
• Do not install a fuse that has a higher rating than the one originally installed in the
product. Do not bypass fuses.
• Do not stick filters, masks or other materials onto optical components.
• The product’s optical components can focus the sun’s rays, creating a risk of fire and
damage. Do not expose the front of the product to sunlight or any other intense light
source, even from an angle.
Eye safety
• The impression FR1 is classified as a Risk Group 2 product according to EN 62471.
Possibly hazardous radiation emitted. Do not stare into the light output from the
product. May be harmful to the eyes.
impression FR1 User Manual 5
www.glp.de
• Do not look at the product’s light output with optical instruments or any device that
may concentrate the light output.
• Make sure that persons working on or near the product are not looking directly into
the light output when the product lights up suddenly. This can happen when power is
applied, when the product receives a DMX signal, or when certain control menu
items are selected.
• Provide well-lit conditions to reduce the pupil diameter of anyone working on or near
the product.
Strobe safety
• Flashing light, particularly at 5 - 30 Hz, may cause seizures in persons with
photosensitive epilepsy. Do not use strobe effects for extended periods.
• Comply with local regulations on the use of strobe lighting and notify the public in
advance with highly visible warning signs when strobe effects are used.
• If a seizure occurs, stop using strobe effects. Protect the affected person from injury.
Move the person to a safe place and sit them down or lay them on their side with
their head supported to prevent it from hitting the floor. Do not use force. Seek
emergency medical help if the seizure lasts for more than a few minutes.
Installation safety and protection from personal injury
• Installation must be performed by qualified personnel only and carried out in
accordance with applicable regulations such as BGV C1 and DIN VDE 0711-217.
• The product is not portable when installed.
• Ensure that the supporting structure and installation hardware used can hold at least
10 times the weight of the load that they support.
• Suspend the product with hardware specifically designed and rated for the purpose.
Check that the hardware is in perfect condition. Fasteners must be steel grade 8.8
strength or better. Rigging clamps must be half-coupler type that completely encircle
the rigging truss chord.
• Screws or bolts used for mounting hardware must protrude minimum 9 mm / 0.36 in.
and maximum 11 mm / 0.43 ins. into the threaded holes in the base of the fixture.
• If the product is installed in a location where it may cause injury or damage if it falls,
install as directed in this manual a safety cable or similar secondary attachment that
will hold the product if a primary attachment fails. The secondary attachment must
be approved by an official body such as TÜV as a safety attachment for the weight
6 impression FR1
User Manual
German Light Products
that it secures, it must comply with EN 60598-2-17 Section 17.6.6, and it must be able to
support a static suspended load that is ten times the weight that it secures.
• Fasten the product to a structure or surface as directed in this user manual. Do not
use safety cables as the primary means of support.
• Before applying power to the product, ensure that the moving head can move
through its full range without risk of collision. Allow a minimum center-to-center
distance of 360 mm / 14.2 in. between fixtures.
• Check that all covers and rigging hardware items are secure.
• Do not operate the product with missing or damaged covers, shields or any optical
component.
• Restrict access below the work area and work from a stable platform whenever
installing, servicing or moving the product.
• If the product becomes damaged, stop using it immediately and disconnect it from
power. Do not attempt to use a product that is obviously damaged.
• Do not modify the product in any way not described in this user manual.
• Install genuine GLP parts only.
impression FR1 User Manual 7
www.glp.de
2. Avoiding damage
Do not point the front of the fixture towards the sun or other strong light sources. The
front lens focuses and concentrates light just like a magnifying glass. Strong light can
cause internal damage to the fixture, melting components or starting an internal fire
within seconds.
Figure 1. Avoiding damage from light sources
Damage can occur whether the fixture is powered on or off. See Figure 1.Damage
can also occur if the light hits the front of the fixture at an angle: the fixture does not
need to be pointing directly at the sun or other light source.
To avoid problems from strong light sources:
• Do not expose the front of a fixture to sunlight or any other strong light source.
• For outdoor applications during daylight, make sure that the front face of any fixture is
shielded or points away from the sun, even when not in use.
• Avoid pointing other high-powered beam lights directly at the fixture.
Do not pick up or carry the fixture by the front lens bezel. The LCD display is also fragile.
Picking up or supporting the fixture in these spots could result in damage that is not
covered by the warranty.
Use only original spare parts. Any structural modification of the system will void the
product warranty.
Clean optical components only as directed. Oils, solvents, and other chemicals
commonly used for cleaning can damage the lens coatings and surfaces.
Do not drop the product or expose it to mechanical stress.
Do not expose the product to heat (from other lighting fixtures for example).
Transportation and storage
Transport the impression FR1 either in a flightcase or in its original packaging to protect
the fixture from damage caused by shocks during transportation.
Store the fixture in a dry location when not in use.
8 impression FR1
User Manual
German Light Products
3.Product overview
A
B
G
I
A – Front lens assembly
B – Control panel with backlit LCD display
C – DMX in
D – Safety cable attachment point
H
Figure 2: Product overview
F
C
D
E
E – AC mains power in
F – Cooling vent
G – DMX out (thru)
H – Safety cable attachment point
I – AC mains power out (thru)
impression FR1 User Manual 9
www.glp.de
4. Product features
The impression FR1 from GLP is a high-quality moving head lighting fixture with a
60 watt RGBW LED and advanced optics that give a powerful, homogenous and
sharply defined beam throughout the fixture’s 10:1 zoom range. Advanced German
design allows exceptional performance and a versatile feature set to be packed into
one of the most compact moving head lighting fixtures currently available, with GLP’s
familiar baseless format. The fixture is designed for ease of installation, with Neutrik
PowerCON IN and THRU connections allowing daisy-chained power lines.
The impression FR1 is designed for permanent or temporary indoor use. It can be used
outdoors if it is protected from moisture and precautions are taken to prevent damage
from direct sunlight. It may be placed upright on a level surface or suspended from a
suitable structure as described this manual.
The impression FR1 is not suitable for household use, for use in any location where
unattended children have access to it, or for use in permanent outdoor installations.
Light source
The impression FR1 is equipped with an OSRAM Ostar RGBW LED with a rated lifetime of
50 000 hours.
Removable micro-Fresnel lens
A detachable micro-Fresnel lens is fitted to the front of the fixture to give a smoother
beam. It is possible to remove this lens to obtain a harder-edged beam (see page 27).
Pan and tilt
The impression FR1 pans through 540° and tilts through 220° with coarse and fine
control channels and self-correcting position feedback.
Pan and tilt position feedback can be disabled using the control panel or the Settings
DMX channel.
The direction of pan and tilt movement can be reversed by selecting Invert command
using the control panel or the Settings DMX channel, and you can also swap pan and
tilt via the control panel. Inverting and swapping movement is a fast way of obtaining
symmetrical effects without reprogramming at the console.
The default settings for position feedback, inversion and swapping are OFF.
Continuous (endless) pan rotation is also available on a separate DMX channel.
Color
The impression FR1 provides both color presets and 0-100% continuous RGBW color
mixing.
You should normally set RGBW levels to 100% when you begin to use the color presets
channel, but after you have selected a color on the color preset channel you can
fine-tune it using the RGBW channels.
10 impression FR1 User Manual
German Light Products
CTC
The CTC DMX channel lets you adjust color temperature from 2500 to 10 000 K.
You should normally set RGBW levels to 100% when you begin to use the CTC channel,
but after you have selected a color temperature on the CTC channel you can finetune it using the RGBW channels.
Shutter effects
The impression FR1 features an electronic dimmer / shutter system that provides pulse
and strobe effects.
Dimming
0 – 100% continuous dimming is available.
Light
output
DMX control value
Figure 3. Dimming curves
See Figure 3. You can select from three different dimming curves using the control
panel or the Settings DMX channel: Linear, Soft and Extra soft:
• Light output using the Linear curve will appear to increase and decrease evenly
throughout the dimming range.
• The Soft and Extra soft curves give finer control at low light levels (where the eye is
more sensitive to changes in light level) and coarser control at high levels.
The default setting is Extra soft.
Fan modes
The four different cooling fan modes give you a range of options to choose from
depending on how much you want to give priority to high-intensity light output or to
low fan noise:
•Fan regulated gives priority to light output. If the fixture is blacked out, fans run at
minimum speed. When light output intensity is increased, temperature regulation
impression FR1 User Manual 11
www.glp.de
increases fan speed to the level necessary to keep the fixture at optimum
temperature.
If light output is set to maximum intensity but the fans can keep the fixture at optimum
temperature, there will be no regulation of light intensity. If the fixture begins to
exceed optimum temperature, light intensity will be reduced until optimum
temperature can be maintained.
•Fan constant high mode is optimized for maximum light output and suits operation in
high ambient temperatures. Fans are set to constant operation at high speed and
light output intensity is regulated in order to keep fixture temperature at optimum
level.
Besides maximizing light output in high ambient temperatures, you can use this mode
to cool down a fixture quickly or to remove dust from cooling fans.
•Fan constant medium mode is suitable for low-noise operation in normal ambient
temperatures. Fans are set to constant operation at medium speed and light output
intensity is regulated in order to keep fixture temperature at optimum level.
•Fan constant low mode is optimized for minimum noise. Fans are set to constant
operation at low speed and light output intensity is regulated in order to keep fixture
temperature at optimum level.
This mode gives an extremely low fan noise level, but if you use it in high ambient
temperatures there may be a noticeable reduction in light output intensity.
In all fan modes, if fixture temperature reaches a dangerous level, LEDs will be shut
down for a period until the fans have brought the temperature down to a safe level.
You can set the cooling fan mode using the control panel or the Settings DMX
channel.
Zoom
The impression FR1 has a 10:1 zoom range. You can narrow the beam angle from 35° in
flood mode to 3.7° in spot mode.
Zoom can be inverted from flood spot to spot flood using the control panel and
the Settings DMX channel. The default setting for zoom inversion is OFF.
Control panel
The control panel on the side of the yoke has a backlit graphic LCD display for setting
up the fixture and changing fixture settings. See ‘Control menu layout’ on page 19 for
a table showing the control menu structure and options available.
PWM frequency
You can change the LED dimming PWM frequency using either a DMX command or a
control panel setting in order to avoid flicker and beat frequencies in video images.
The default PWM setting is 582 Hz. You can adjust the PWM frequency continuously
from 582 to 618 Hz, or you can set it to either 1200, 2400, 4800 or 9600 Hz. Note that a
higher PWM frequency may affect dimming performance.
12 impression FR1 User Manual
German Light Products
The PWM frequency setting is stored in the fixture and is not affected by cycling power
off and on. However, it will be affected if you use the Factory default command in the
control menus.
You should set all the fixtures in an installation to the same PWM frequency in order to
ensure the same performance. As described above, you can do this using the PWM
frequency selection or Factory default commands in the control menus or using the
PWM frequency DMX channel.
Installation options
The base provides M10 threaded holes for direct fastening of half-coupler clamps. A
countersunk M10 bolt for clamp attachment is supplied with the fixture.
Two eyelets are provided for safety cable attachment.
impression FR1 User Manual 13
www.glp.de
5. Preparation for use
Warning! Read ‘Safety’ starting on page 3 for important safety information
that you must understand before you install or operate the fixture.
Included Items
The impression FR1 is supplied with a power cord with PowerCON connector and an
M10 x 11 countersunk bolt for fastening a half-coupler clamp to the base of the fixture.
Orientation and location
The impression FR1 may be rigged in any orientation or placed on a level surface.
Keep the head at least 0.5 m (20 in.) away from combustible materials (including
curtains and stage scenery) when the fixture is installed.
Make sure that there is no risk of collision when the head pans and tilts. Allow a
minimum center-to-center distance of 360 mm / 14.2 in. between impression FR1
fixtures.
Mounting on a rigging truss
To mount the FR1 on a rigging truss or similar support in any orientation:
Pass an M10 steel bolt or screw through a half-coupler type rigging clamp and
check that the bolt will protrude minimum 9 mm / 0.35 in. and maximum 11 mm /
0.43 in. into the base of the fixture when tightened.
B
Figure 4. Mounting points in base
14 impression FR1
A
B
User Manual
German Light Products
See Figure 4. Fasten the bolt through the rigging
clamp into hole A in the center of the base of the
fixture so that the rigging clamp is held securely.
You can also install narrow half coupler clamps
through holes B, but these extra clamps are not
necessary.
Fasten the rigging clamp securely around a chord
on a rigging truss or similar bar.
See Figure 5. Attach a safety cable to one of the
safety cable attachment points in the fixture base
and loop it around the truss chord or bar so that it
will hold the fixture if the rigging clamp fails. Take
up as much slack as possible in the safety cable
(by looping it more than once around the truss, for
example).
Make sure that the head will not collide with
another fixture or any other object when it tilts
and rotates.
Figure 5. Safety cable
attachment
Placing on a surface
You can stand the FR1 upright on its rubber feet on a flat, stable, horizontal surface.
If necessary to prevent the fixture from moving if the surface is slippery or falling, pass a
ratchet strap, webbing or other bracing strap through the safety cable attachment
points (see Figure 5) and fasten it to secure anchoring points.
Make sure that the head will not collide with anything when it tilts and rotates.
Connecting to power
The AC mains power supply must include a connection to ground / protective earth. It
must be protected against ground / earth leakage and overload. The autosensing
power supply accepts AC power at 100-240 V, 50/60 Hz. Do not connect the fixture to
power at any other voltage or to an external dimmer.
The FR1 does not have a power ON/OFF switch. Power is applied to the fixture as soon
as the power cable becomes live.
The impression FR1 has a 3-conductor Neutrik PowerCON socket that accepts AC
power from a Neutrik PowerCON female cable connector.
Important! PowerCON connectors do not support hot-plugging. Shut down power to
the power cable before you connect it to the fixture, or you may cause arcing and
deterioration of the contacts at the connector.
impression FR1 User Manual 15
www.glp.de
To connect the fixture to power:
Check that power to the power input cable is shut down.
See I in Figure 2 on page 9. Connect the power input cable to the Mains In socket
by inserting and twisting clockwise to lock.
Before applying power, check that the head is unlocked and can move freely and
check that nobody is looking directly into the front of the fixture.
Connecting multiple fixtures to power in a chain
You can connect fixtures to power in a daisy-chain to simplify your power circuit
layout.
Warning! The power input cable supplied with the fixture is rated 16 A
maximum. Add together the maximum current draw ratings of all the
devices that you intend to connect to power in a daisy chain and do not
create a chain with a total maximum current draw of more than 16 A, or
you will create a risk of fire and electric shock. Do not connect more than sixteen (16)
impression FR1 fixtures to power in a chain at 100-120 V, 60 Hz. Do not connect more
than thirty-two (32) impression FR1 fixtures to power in a chain at 200-240 V, 50 Hz.
To connect fixtures to power in a chain:
Obtain power relay cables that have male and female Neutrik PowerCON
connectors. Cables must be minimum 14 AWG or 1.5mm2, rated minimum 16 A and
suitable for the environment and application.
Check that the total current draw of all the devices in the chain will not exceed
16 A.
Check that power is not applied to the input cable.
Connect the power input cable to the Mains In socket (see I in Figure 2 on page 9).
Connect a relay cable to the Mains Out socket (see E in Figure 2 on page 9) of the
first fixture and to the Mains In socket of the next fixture in the chain. Continue until
the chain is complete.
Before applying power, check that the heads are unlocked and can move freely
and check that nobody is looking directly into the front of a fixture.
Installing power connectors
It is possible to install a cord cap / mains power plug that is suitable for your local
convenience receptacles / power sockets on the supplied power input cable. If you
do this, check that the cord cap / plug is rated minimum 250 V, 16 A, that it has a
connection to ground / earth and that it has an integral cable grip. Follow the cord
cap / plug manufacturer’s assembly instructions.
If you need to install a Neutrik PowerCON connector on a power cable, follow the
instructions given in the Support area of the Neutrik website at www.neutrik.com.
16 impression FR1
User Manual
German Light Products
Respect the color coding used in the supplied power cable and in your local mains
power wiring system. US and EU systems use the color coding shown below:
US system Black White Green
EU system Brown Blue Yellow/green
Live or L Neutral or N
Ground / Earth or
Main fuse
See Figure 6. The main fuse sits in a holder in
the bottom of the base.
If the fixture appears to be completely shut
down even though power is applied, the
main fuse may have blown. Disconnect the
fixture from power before replacing the fuse.
Replace only with a fuse of the same type
and rating.
Figure 6. Main fuse
Connecting to a DMX control data link
The impression FR1 provides 5-pin XLR IN and THRU sockets for connection to a USITT
DMX512 data link.
Connectors use standard DMX pinout:
• Pin 1 = Ground
• Pin 2 = -ve / data cold
• Pin 3 = +ve / data hot.
• Pins 4 and 5 are not used.
If you would like any advice with planning and installing a DMX link, your GLP supplier
will be happy to provide assistance.
impression FR1 User Manual 17
www.glp.de
6. Control menus and LCD display
Warning! DMX control is disabled when the control menus are active. Be
prepared for the head to move as soon as you exit the control menus.
The control panel and LCD display provide access to user settings, readouts, and
utilities.
When power is applied, the fixture resets and impression and FR1 appear the display
panel. After the reset has completed, the main menu is displayed:
V:0.12/NE 582
-214
Next
198
DMX Start Address
215
Mode Enter Down UP
OO
Figure 7. Main menu
See Figure 7. From left to right, the top line of the main menu displays:
• Main CPU software version
• Pan, tilt, and zoom modes: N (Normal) or I (inverse)
• Dimming curve: L (Linear), S (Soft) or E (Extra Soft)
• PWM frequency.
In the example shown in Figure 7, the fixture is running CPU software version 0.12 with
normal pan, normal tilt, normal zoom and extra-soft dimming. The current PWM
frequency is 582.
A flashing display indicates loss of DMX.
To use the control panel:
O
O
• Use the Down and Up buttons to scroll between menu options.
• Press the Enter button to select a setting, confirm a command or enter a submenu.
• Press the Mode button to escape and return to the top of the menu.
18 impression FR1
User Manual
German Light Products
7. Control menu layout
DMX Start
Address
Setup DMX Mode NORM
Settings
1 - 512 DMX start address
Invert Pan
Invert Tilt ON / OFF Invert tilt up/down
Swap
Pan/Tilt
Position
Feedback
Pan/Tilt
Pan Enable ON / OFF
Tilt Enable ON / OFF
Zoom Invert Zoom ON / OFF
Error
Blackout
Shutter
Init
Positions
Dimming
Curve
DMX hold
No DMX
Blackout
Save
Reset
Linear
Soft
Extra Soft
Off
Fade Out
Hold
ON / OFFInvert pan left/right
ON / OFFSwap Pan/Tilt channels
ON / OFF
ON / OFF
ON / OFF
Disable position
encoders for Pan/Tilt
On: Enabled and
controllable via DMX
Off: Disabled and no
motor current
On: Enabled and
controllable via DMX
Off: Disabled and no
motor current
Zoom inverted from
Flood Spot to
Spot Flood
Light output is stopped
if an error occurs
Light output is stopped
if DMX fails for 3
seconds
Save current positions
as initial positions after
reset without DMX
Reset initial positions
after reset without DMX
Select dimming curve
option
Fixture blacks out if
DMX signal is lost
Fixture fades out if DMX
signal is lost
Last DMX values are
held if signal is lost
impression FR1 User Manual 19
www.glp.de
Settings
(continued)
Information
PWM
Frequency
Display
Temperature
Unit
Fan Mode
Clear
EEPROM
Reset
Factory
Settings
System Errors List
System
Versions
582-618 Hz / 1200 Hz / 2400 / 9600 Hz
Contrast 0 - 50 -100 %
Brightness 0 - 100 %
Blackout
Time
Display
Orientation
No DMX
Flash
°C / °F
Auto
Constant high
Constant medium
Constant low
0 - 255
Confirm (Yes/No)
Main (SW/HW)
Pan/Tilt (SW/HW)
LED Driver (SW/HW)
1 - 10 -30 s
Normal / Inverted
ON / OFF
Set LED PWM
frequency
Set display
contrast
Set display
brightness (Auto
Brightness must
be disabled)
Set time until
display blackout
after last
keystroke (Auto
Blackout must be
enabled)
Flip display
up/down
Display flashes if
DMX fails
Sets units shown
in display
Temperatureregulated
cooling fan
operation
Constant cooling
fan speed
Clear time and
power on values
Reset all values
(except serial
number) to
factory defaults
Show all recent
errors
(permanent)
Main fixture
software (main
application, boot
loader) and
hardware
versions
Pan/tilt software
and hardware
versions
LED driver and
hardware
versions
20 impression FR1 User Manual
German Light Products
-128 - 127
°C/°F
-128 - 127
°C/°F
-128 - 127
°C/°F
-128 - 127
°C/°F
-128 - 127
°C/°F
-128 - 127
°C/°F
0-99999 h
Main head
temperature
sensor readouts
LED
temperature
readouts
Total operation
time from new
Resettable hours
counter
Number of times
fixture has been
started up (nonresettable)
DMX values
received on
each channel
Fan speeds (and
voltages)
Temperatures
Fixture
Information
Information
(continued)
DMX Input
Monitor
Fans Monitor
Current
Main
Temperature
LED
Temperature
Fixture Hours
Boot count 0-99999
Pan
Zoom
Speed Movements
Pan/Tilt Movements
PWM / Special
White Temperature
Dimmer
Shutter
White
Blue
Green
Red
Color Wheel
Tilt
PSU Fan RPM (/U)
Head Fan RPM (/U)
Maximum
resettable
Maximum
nonresettable
Current
Maximum
resettable
Maximum
nonresettable
Total hours 0-99999 h
Resettable
hours
impression FR1 User Manual 21
www.glp.de
Reset
Manual
Control
Manual
DMX
Full System
Reset
Pan/Tilt
Reset
LED Driver
Reset
Pan
Confirm (Yes/No) Reset fixture
Confirm (Yes/No)
Confirm (Yes/No) Reset LED driver only
0 - 255
Zoom 0 - 255
Speed
Movements
Pan/Tilt
Movements
0 - 255
0 - 255
Special 0 - 255
White
Temperature
0 - 255
Dimmer 0 - 255
Shutter 0 - 255
White 0 - 255
Blue 0 - 255
Green 0 - 255
Red 0 - 255
Color Wheel 0 - 255
Tilt 0 - 255
Reset All
Values
Confirm (Yes/No)
Reset pan and tilt
only
Manually apply
DMX values (these
commands are
available if no DMX
is present – values
are overwritten by a
DMX signal). Values
are reset to initial
values after a fixture
reset.
Set all manual DMX
values to 0
22 impression FR1 User Manual
German Light Products
Pan/Tilt ON / OFF
Test
Service
Colour ON / OFF
All ON / OFF
Key Code 0 - 255
Serial 0 - 99999
Red
LED
Calibration
Pan 0 - 128 - 255
Tilt 0 - 128 - 255
Zoom 0 - 128 - 255
Green 0 - 128 - 255
Blue 0 - 128 - 255
White 0 - 128 - 255
0 - 128 - 255
Run test sequence
Enter code to
access Service
Menu (resets
automatically after
fixture restart or after
10 min. with no
control panel input)
Last 5 digits of
fixture’s serial
number. Needed for
correct RDM
operation
Adjust base RGBW
intensity
Adjust pan home
position
Adjust tilt home
position
Adjust zoom home
position
Default values are shown in bold type.
User-settable values are displayed in grey boxes.
impression FR1 User Manual 23
www.glp.de
8. DMX channel layout
Normal mode (16 DMX channels)
Channel Function Description
1
2
3
4
5
6
7
8
9
10
11
12
13
Pan coarse
Pan fine
Tilt coarse
Tilt fine
Color presets
(virtual color
wheel)
Red Color mixing - Red 0 – 255 255 0 – 100% Fade
Green Color mixing - Green 0 – 255 255 0 – 100% Fade
Blue Color mixing - Blue 0 – 255 255 0 – 100% Fade
White Color mixing - White 0 – 255 0 0 – 100% Fade
Shutter / strobe
Dimmer coarse
Dimmer fine
CTC RGBW raw
Left – right in 1.2°
increments (16 bit)
Up – down in 1.2° increments
(16 bit)
RGBW control
Color 01 - Red
Color 02 - Amber
Color 03 - Warm yellow
Color 04 - Yellow
Color 05 - Green
Color 06 - Turquoise
Color 07 - Cyan
Color 08 - Blue
Color 09 - Lavender
Color 10 - Mauve
Color 11 - Magenta
Color 12 - Pink
White – CTO
White
White – CTB
Rainbow effect stop
Rainbow effect active
Random colors slow – fast
Shutter closed
Shutter pulse random
Fade on, snap off (random
patterns)
Snap on, fade off (random
patterns)
Fade on, fade off (random
patterns)
Strobe with blackout pause
Strobe effect slow - fast
Shutter open
Percentage values are calculated by dividing DMX values by 2.56 and rounding to the
nearest 0.1%.
To apply a command on Channel 14 (Settings), start at a value of zero, then move to
the required value and hold it for at least 3 seconds. If you move to the required value
from any other value than zero, the command will not be applied.
To adjust the PWM frequency using the Settings channel, start at a value of zero, move
to the required value and hold it for at least 5 seconds.
26 impression FR1 User Manual
German Light Products
9. Service and maintenance
Warning! Read ‘Safety’ starting on page 3 for important safety information
that you must understand before you service the fixture. Work in well-lit
conditions. Do not look directly into the light output.
Maintenance
Suggested maintenance intervals
The cleaning schedule depends on the operating environment. The intervals below are
suggestions from our experience with typical installations. Adjust as necessary.
Maintenance Task Interval How
Clean front lens Weekly
Clean fans and air channel Monthly
Lubricate zoom rails Yearly
Wipe with soft cloth and glass cleaning
fluid.
Use soft brush and vacuum cleaner,
compressed air, etc. Hold fans still with pen
or screwdriver to avoid spinning them with
vacuum or air jet.
Apply very small quantity of Klüber Barrierta
to rails.
Cleaning
impression FR1 components require occasional cleaning to prevent the buildup of
dust, dirt, and smoke fluid residue. Pay special attention to the air vents and front lens.
Failure to keep the fixture clean will significantly reduce light output and may cause
damage. Do not let optical parts come into contact with oil or grease or touch with
bare fingers.
Regular cleaning will ensure the maximum performance and reliable operation. The
lenses and glass gobos may be cleaned with alcohol wipes or a soft cloth moistened
with isopropyl alcohol.
Wait until all parts are dry before operating the fixture.
Lubrication
The only parts that may require occasional lubrication are the focus/zoom rails.
Contact GLP Service and Support for advice.
Removing and reinstalling the micro-Fresnel lens
If you would like to obtain a sharper-edged beam, you can remove the micro-Fresnel
lens that is installed in the front of the head (bear in mind that this will result in a slight
loss of evenness in the beam projection). The lens is held by three screws. A frost filter is
installed immediately under the lens.
impression FR1 User Manual 27
www.glp.de
To remove the micro-Fresnel lens:
Shut down power to the fixture and allow it to cool.
Figure 8. Removing a micro-Fresnel lens
See Figure 8. Remove the three Phillips #1 screws (arrowed) from the lens in the
front of the head.
Tilt the head downwards and allow the lens A and frost
filter B to slide out of the head. Store the lens for possible
re-use.
Reinstall the frost filter in the head by passing the three
screws through the notches in the filter and tightening
them into their holes in the head.
If you reinstall the micro-Fresnel lens later, use the three
Phillips screws to fasten it into its original position over the
frost filter. See Figure 9. The smooth side of the lens must
face inwards and the ridges must face out of the head.
Figure 9. Lens
orientation
GLP Service and Support
Contact information for the nearest GLP Service and Support is available online at
www.glp.de/en/service, by request via email at info@glp.de, or by telephone at the
following numbers:
• GLP Germany: +49 (7248) 927 1955
• GLP N. America: +1 818 767-8899
• GLP U.K.: +44 1392 690140
• GLP Asia: +852 (3151) 7730
• GLP Nordic: +46 737 57 11 40
28 impression FR1
User Manual
German Light Products
10. Technical specifications
Light source
LED type: Osram Ostar RGBW
LED lifetime: 50.000 hours
Number of LEDs: 1
CRI (Ra): 80
TLCI: 80
TM30-15 77/106
Color mixing: RGBW continuous
Color presets: 12 + 3 whites, adjustable via RGBW
Color temperature correction: 2500 K – 10 000 K, electronic, adjustable via RGBW
Dimmer: 0-100% continuous, electronic
Shutter/strobe: Pulse and strobe effects, max. 14 Hz, electronic
Variable PWM frequency
Movement
Resolution: 8 - 16 bit
Positional feedback: Yes
Pan range: 540°
Tilt range: 220°
Endless movement: 360° endless pan rotation
Control
Control system: USITT DMX512
Onboard interface: Control panel with backlit LCD graphical display
Installation
Orientation: Any
Rubber feet for standing installation
Hanging vertical installation: M10 threaded sockets for fastening half-coupler rigging
clamps
Eyelets for attaching safety cable
Connections
AC mains power in and out (thru): Neutrik PowerCON
DMX data in and out (thru): 5-pin XLR
impression FR1 User Manual 29
www.glp.de
Electrical
AC power: 100-240 V, 50/60 Hz
Maximum power consumption @230 V: 80 W
Power consumption at idle: 14 W
Primary fuse: 20 mm T 5A
EEC (Energy Efficiency Class): E
EEI (Energy Efficiency Index): 1.193
Energy consumption (kWh/1 000 h): 68
Thermal
Temperature-regulated forced air cooling
Thermal protection system
Maximum ambient temperature: 45° C / 115° F
Minimum ambient temperature: 5° C / 41° F
Product color
Black (standard)
Included items
Power cable (depending on region):
- US power cable: 16 A, 14 AWG, UL listed, E304117, SJT, 4.9 ft.
- EU power cable: 16 A, 1.5mm², H05VV-F, 1.5 m
M10 x 11 bolt for rigging clamp attachment
Shipping options
Single product: Cardboard packing case
Tour packs: 6-fixture and 12-fixture flightcases
Dimensions and weight
Depth: 140 mm / 5,5 ins.
Width: 190 mm / 7.5 ins.
Height (head vertical, zoom at max. extension): 355 mm / 14.0 ins.
Weight: 4 kg / 8.8 Ibs.
30 impression FR1 User Manual
German Light Products
11. Dimensions
impression FR1 User Manual 31
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.