GLP Impression 120RZ RGB Instruction Manual

from software version 1.24/30 (Instruction version 1.5)
e-mail: service@glp.de
Internet: http://www.glp.de
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
2
Notes:
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
3
Table of contents
1 Description of Device.............................................................................................. 4
1.1 Safety Instructions ............................................................................................ 5
2 Preparation and Installation ................................................................................... 6
2.1 Mounting ........................................................................................................... 6
2.1.1 Mounting on the floor (upright) ............................................................. 7
2.1.2 Mounting in hanging position (head down) .......................................... 8
2.1.3 Mounting in a sideway position ............................................................ 8
2.2 Securing the Device .......................................................................................... 9
2.3 Connections ...................................................................................................... 9
2.3.1 Power Supply....................................................................................... 9
2.3.2 DMX ................................................................................................... 10
3 The Menu Field ...................................................................................................... 10
4 DMX Channel Selection (DMX Protocol) ............................................................. 13
5
5 Maintaining and Cleaning the IIMMPPRREESSSSIIOONN ....................................................... 18
5.1 Safety regulations ........................................................................................... 19
5.2 Maintenance Intervals (rule-of-thumb) ............................................................ 19
6 Technical Specifications ...................................................................................... 20
7 Index ....................................................................................................................... 21
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
4
1 Description of Device
1. Moving head (actively and passively cooled)
2. Arm with various cooling vents
3. LCD-Display/Menu (data entry)
4. Base with various connectors and Camlock mounting system
1
2
3
4
5
base side 1
6
base side 2
7891010
FUSE T4A
5. Power On/Off
6. DMX- Output (3 pole)
7. DMX- Input (3 pole)
8. Micro-fuse 5x20mm, T5A
9. Mains supply (Powercon)
10. 2x Safety eyes
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
5
1.1 Safety Instructions
The IIMMPPRREESSSSIIOONN is an advanced technology product. To guarantee smooth operation, it is necessary to follow the following instructions.
The manufacturer of this device will not take responsibility of damages through any disregard of the information in this user manual. Warranty claims will also be cancelled in the event of the system casing being opened.
1. Make sure that before powering up the fixture, the fans and air inlets are clean and not blocked by anything.
2. Before powering up the fixture, ensure that the moving head part of the fixture can rotate unhindered through its full range of movement.
3. A safety distance of at least 0.5 m to any easily flammable material (e.g. decoration material) must be adhered to.
4. Attention! Don’t touch the device during operation. Parts of the fixture can become hot and can cause injuries and / or damages.
5. The system doesn’t contain any user serviceable parts. Opening the fixture will void the manufacturers warranty.
6. Danger of burning. Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture. Pay attention to possible hot parts of the system.
7. Never look directly into the beam of light or one of the LEDs. Never use optical apertures with a distance less than 0.5 m to observe the beam of light. LED Class 2M. Not following these precautions can result in serious injury to your eyes and in particular, your retina.
Attention: LED Cla
ss 2M can cause injuries of your eyes even
without optical instruments in front of them or within a distance of less than 0.5m and short exposure time.
Avoid direct radiation to your eyes!
8. To ensure proper operation, you must also follow the installation guide described in chapter 2 of this manual. Operating the IIMMPPRREESSSSIIOONN without suitable mounting devices can increase the risk of an accident.
9. The IIMMPPRREESSSSIIOONN features a unique small and lightweight design with no specific carrying handles. Care needs to be shown when handling the fixture to ensure that no unnecessary damage should occur. Fragile areas include the LCD display and cover on one side arm and the front bezel.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
6
Pressure in these areas could result in damages which will not be covered by the standard warranty.
10. Repair-, maintenance- and installation work should only be performed by qualified or GLP certified staff. You need to pay attention to the common rules of technology that are not explicit mentioned in this manual.
11. Use only original spare parts. Any structural modification on the system will terminate all warranty claims.
12. Please keep this instruction manual for future reference.
2 Preparation and Installation
2.1 Mounting
The IIMMPPRREESSSSIIOONN is fully operational whether it hangs or is mounted to a wall. It can also be operated while standing on the floor. Keep a safety distance of
0.5 m from any easily inflammable materials (decoration etc.).
Pay attention to the regulations of: BGV C1 (former VBG 70)
and DIN VDE 0711-217.
The installation shall be done by qualified personal only.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
7
For the various mounting positions of the IIMMPPRREESSSSIIOONN (standing on the floor, sideways or hanging) different accessories kits are available. Using any required kits, along with the standard mounting connectors on the base of the fixture, will ensure a safe and firm installation.
1x M10
(length max.16mm)
2x Camlock
quick release
fasteners
front side of the fixture
2.1.1 Mounting on the floor (upright)
To operate the IIMMPPRREESSSSIIOONN in an upright position, please use the dedicated floor-stand which ships with all original fixtures. The floor stand is mounted to the base of the fixture using the two Camlock quarter turn fasteners. Line up and engage the camlock connectors from the floor stand into the base of the fixture and turn the two fasteners 90° to lock them. Do the opposite to release them again. On both sides you'll find eyelets to pull though a fixing strap. This allows additional bracing of the floor-stand during the upright operation.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
8
2.1.2 Mounting in hanging position (head down)
To operate the IIMMPPRREESSSSIIOONN in a hanging position, a half-coupler or similar clamp can be mounted directly to the bottom of the base using the M10x16 mm threaded socket.
M10x16
2.1.3 Mounting in a sideway position
To operate the IIMMPPRREESSSSIIOONN in a sideways position, please use an additional mounting bar, available from GLP or one of their agents.. This mounting bar is fixed via the two camlock quick-release connectors. Two half-couplers or clamps are then used to hang the mounting bar. This technique is necessary to cope with the additional torque in this mounting position. Never use the "Mounting in hanging position" technique described above to secure the fixture in a sideway position, as the fixtures base can become damaged, and a secure installation cannot be assured.
2x Camlock
2x Eyelets
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
9
2x 90°
Half-coupler (clamp) 1
Half-coupler (clamp) 2
without mounting bar
2.2 Securing the Device
Regardless of the mounting method of the IIMMPPRREESSSSIIOONN you'll have to use a secondary safety wire. This safety wire can be attached to the fixture by threading it through one of the two holes provided on the base of the fixture. Ensure that the safety wire is securely fastened through the fixture and the fixtures mounting support. Install a safety wire that can hold at least 10 times the weight of the fixture.
2.3 Connections
2.3.1 Power Supply
~100-240 Volt AC, 50-60 Hz, earth contact type plug, via Powercon Connected load 350 VA (W) <=> T5A (micro-fuse 5x20mm)
Disconnect from the mains supply before changing the fuse and use only the above described micro-fuse type.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
10
2.3.2 DMX
USITT DMX-512 Standard input/output with 3 pole connectors. 3 pole: Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+] The DMX- Addressing starts at DMX- Address [001].
3 The Menu Field
You’ll find the control board on the side of the arm. It allows you to make all necessary adjustments of the IIMMPPRREESSSSIIOONN.. With the Mode-key you get into the main menu. Afterwards you can navigate through the menu with the Up/Down-keys. Push the Enter-key to get to the next menu level or to confirm your settings. Select ON/ OFF function settings with the Up/Down-keys. Confirm and save with the Enter-key (the display shows OK). Push the Mode-key to cancel the entry and go back to the main menu.
Mod e
Down
Enter
Up
DOWN - UP

MODE - ENTER 
Level1
Level 2
Level 3
Level 4
Remark
DMX Start
Address 001
Set the DMX start address
Special Manual DMX
Manual control of all system functions
Pan
Manual control for Pan (X-movement)
Speed
Movements
Speed adjustment for Pan/Tilt movements see also item below
Pan/Tilt
Movements
Manual control for Pan/Tilt macro movements
Special
Activate the White- or Full-Power Mode; see also DMX table
White
Temperature
Manual control for color temperature
Dimmer
Manual control for dimmer
Shutter
Manual control for shutter
Blue
Manual control for blue
Green
Manual control for green
Red
Manual control for red
Color Wheel
Manual control for the color wheel mimic
Zoom
Manual control for zoom
Tilt
Manual control for Tilt (Y-movement)
Display
Contrast
Adjustment for the Display contrast
Default Set
Resetting functions
1.10
Resetting all functions to original values (Standard).
a)
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
11
Full Feature
Resetting all functions to original values (Full Feature)
b)
Set Dimmer
Frequency
Changes PWM frequency between 600Hz and 1200Hz
LED Dimmer
Version
Reads out the current LED dimmer (software) version
Impression
Version
Reads out the current CPU software version
Adjust
Key code
xxxx
Use the code to enter the calibration menu (for authorized persons only)
Pan Offset
Calibration for Pan-Offset
Tilt Offset
Calibration for Tilt-Offset
Blue
Calibration for Blue
Green
Calibration for Green
Red
Calibration for Red
Clear
EEPROM
Erase EEPROM memory
Diagnose
Diagnose functions
Pos Feed
Pan Delta
Internal data and function diagnose
Anz Ti0
-
Int-Err
Internal data and function diagnose
PFC
Voltage
Show the present PFC voltage
Pos Feed
Tilt Delta
Internal data and function diagnose
Temperature
Arm
Displays the arm temperature
DOWN - UP
Temperature
Head
Displays the head temperature
PAN/TILT
Motor Power
Switches power for pan/tilt motors ON or OFF
PAN/TILT
Silent Mode
Reduces maximum speed for pan/tilt
Zoom Speed
Select faster zoom speed
DMX Hold
Defines whether the last DMX signal is stored, or the lamp is switched OFF in case of signal interruption
Position
Feedback
Automatic position feedback selection for pan/tilt movement
White
Adjust
Adjustments for a uniform white color; only in white­mode
Red
Adjustment of red
Blue
Adjustment of blue
Green
Adjustment of green
Set DMX
Image
Takes and stores a DMX snapshot of the current DMX input
DMX input
Monitor
Displays the current DMX signal per DMX channel
Pan
Instantaneous value for Pan
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
12
Speed
Movements
Instantaneous value for speed movements
Pan/Til
t
Movements
Instantaneous value for pan/tilt movements
Special
Instantaneous value for special channel
White
Temperature
Instantaneous value for white temperature
Dimmer
Instantaneous value for dimmer
Shutter
Instantaneous value for shutter
Blue
Instantaneous value for blue
Green
Instantaneous value for green
Red
Instantaneous value for red
Zoom
Instantaneous value for zoom
Color Wheel
Instantaneous value for color wheel mimic
Tilt
Instantaneous value for tilt
Self test
Performs an automatic self-test
Live time
Indicates the total operation time of the system
Display
Adjust the display
DOWN - UP
Blackout
Sets the display On or Off
Select DMX
Mode
Allows selection of the desired DMX Mode
Compressed
Fixture works in "Compressed" mode see also sectiion 4
Normal
Fixture works in "Normal" mode see also section 4
High
-
Resolution
Fixture works in "High Resolution" mode see also section 4
Theater Mode
Selects Theater Mode (Fans quiet) on or off
c)
K2 Mode
Selects K2 Mode (RGB looks like Impression 90) on or off
d)
White Mode
Selects the activation of Adjustments for white­balance, on or off.
Reverse Pan
Selects Inverse Pan, on or off
Reverse Tilt
SelectsInverse Tilt on or off
Reset
RESET all functions
a)
Default Set 1.10
This mode resets the IIMMPPRREESSSSIIOONN ttoo iittss ssttaannddaarrddss lliikkee ffoorrmmeerr ssooffttwwaarree vveerrssiioonnss.. ((DDMMXX aaddddrreessss
rreesseett,, PPaann//TTiilltt iinnvveerrtt rreesseett,, PPWWMM ffrreeqquueennccyy rreesseett,, ssttaannddaarrdd ddiimmmmeerr ccuurrvvee,, ccoolloorr ccoorrrreeccttiioonn ddooeessnn´´tt wwoorrkk wwiitthh RRGGBB,, nnoo RRDDMM))
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
13
b)
Default Set “Full Feature”
This mode resets the IIMMPPRREESSSSIIOONN ttoo iittss ssttaannddaarrddss aanndd wwiitthh ssoommee nneeww ffeeaattuurreess ((DDMMXX aaddddrreessss rreesseett,,
PPaann//TTiilltt iinnvveerrtt rreesseett,, PPWWMM ffrreeqquueennccyy rreesseett,, nneeww ddiimmmmeerr ccuurrvvee,, ccoolloorr ccoorrrreeccttiioonn wwoorrkkss wwiitthh RRGGBB,, RRDDMM)
)
c)
Theater Mode
This mode runs the fans of the fixture slower, reducing noise.. If the temperature of the IIMMPPRREESSSSIIOONN becomes too hot the fans do not increase in speed. Instead, the LED´s will dim down from their output level to reduce the heat.
d)
K2 Mode
This mode adjusts the IIMMPPRREESSSSIIOONN 112200 RRZZ RRGGBB ttoo tthhee ccoolloorr mmiixxiinngg ooff tthhee IIMMPPRREESSSSIIOONN 9900 RRGGBB..
4 DMX Channel Selection (DMX Protocol)
Normal-Mode 15 DMX channels
Channel
Function
Time and Value
DMX
HEX %
1) PAN
-
coarse
0 .. 660° 3,2 s 0..255 00..FF 0..100
2) PAN
-
fine
High- Pos ... High- Pos + 2,6° (16 Bit) 0..255 00..FF 0..100
3) Tilt
-
coarse
0 .. 300° 1,5 s 0..255 00..FF 0..100
4) Tilt
-
fine
High- Pos … High- Pos + 1,2° (16 Bit) 0..255 00..F F 0..100
5) Col
or
Colors adjustable via RGB 0..7 00..07 0..2,5
(fixed)
Color 01 - Red 1) 8..15 08..0F 3..5,5 Color 02 - Amber 1) 16..23 10..17 6..8,5 Color 03 - Warm Yellow 1) 24..31 18..1F 9..12,5
Color 04 - Yellow 1) 32..39 20..27 13..15,5
Color 05 - Green 1) 40..47 28..2F 16..18,5
Color 06 - Turquoise 1) 48..55 30..37 19..21,5
Color 07 - Cyan 1) 56..63 38..3F 22..24,5
Color 08 - Blue 1) 64..71 40..47 25..27,5
Color 09 - Lavender 1) 72..79 48..4F 28..30,5 Color 10 - Mauve 1) 80..87 50..57 31..34,5 Color 11 - Magenta 1) 88..95 58..5F 35..37,5 Color 12 - Pink 1) 96..103 60..67 38..40,5 White - CTO Color temperature
3200K
104..111 68..6F 41..43,5
White Color temperature
5600K
112..119 70..77 44..46,5
White - CTB Color temperature
7200K
120..127 78..7F 47..49,5
Rainbow Effect Stop 2) 128 80 50 Rainbow Effect 3) slow - fast 129..223 81..DF 51..88 Rainbow Effect, random colors slow - fast 224.255 E=..FF 89..100
6) Red
Color mixing system - Red 0 - 100% 0..255 00..FF 0..100
7) Green
Color mixing system - Green 0 - 100% 0..255 00..FF 0..100
8) Blue
Color mixing system - Blue 0 - 100% 0..255 00..FF 0..100
9) Shutter
Shutter closed 0..15 00..0F 0..5,5
Random Pulse effect slow - fast 16..47 10..2F 6..18,5
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
14
Channel
Function
Time and Value
DMX
HEX %
Up-dimming then Shutter closing
(random patterns)
slow - fast 48..79 30..4F 19..31
Shutter open then down-dimming
(random patterns)
slow - fast 80..111 50..6F 32..43
Up-dimming then down-dimming
(random patterns)
slow - fast 112..143 70..8F 44..56
Strobe effect pause 5s .. 1s 144..199 A0..C7 57..77
Strobe effect, slow - fast 1 Hz .. 10 Hz 200..239 C8..EF 78..94 Shutter open 240..255 F0..FF 95..100
10) Dimmer
Dimmer 0 - 100% 0..255 0..FF 0..100
11) Color
No color temperature correction 0..6 0..06 0..2
temper
ature
Continuous color temperature
correction between 3200k - 7200k
Applicable only for ALL colors 5)
7..255 07..FF 3..100
12) Special
Max. Power-Mode 4) Max. light output without
white balance
0..15 0..0F 0..5,5
White-Mode
4)
White balance used 16..31 10..1F 6..12,5 Theater Mode ON 6) Mode ON 32..35 20..23 13..14 Theater Mode OFF 6) Mode OFF 36..39 24..27 14..15 K2 Mode ON 6) Mode ON 40..43 28..2B 16..17 K2 Mode OFF
6)
Mode OFF 44..47 2C..2F 17,5..19
White Mode ON
6)
Mode ON 48..51 30..33 19..20 White Mode OFF 6) Mode OFF 52..55 34..37 20,5..21 RGB value spreading ON
6)
Mode ON 56..59 38..3B 22..23,5 RGB value spreading OFF 6) Mode OFF 60..63 3C..3F 24..25 Reverse Tilt ON 6) Mode ON 64..67 40..43 25,5..27 Reverse Tilt OFF
6
)
Mode OFF 68..71 44..47 27,5..
28,5 Reverse Pan ON 6) Mode ON 72..75 48..4B 29.. Reverse Pan OFF
6)
Mode OFF 76..79 4C..4F 30,5..
31,5 Fan min. as long as temp. < 90°C 224..229 E0..E5 88..89,5
RESET (Normal Mode)
250..255
FA..FF
98..100
13) Move
- No movement
0 00 0
ment
Movement
Size Phase
PAN 1 01..01 01..01 0,5 1 90° 02..03 02..03 1,0 1 180° 04..05 04..05 1,7 1 270° 06..07 06..07 2,5 PAN 2 08..09 08..09 3,3 2 90° 10..11 0A..0B 4,1 2 180° 12..13 0C..0D
4,9 2 270° 14..15 0E..0F 5,7 PAN 3 16..17 11..11 6,5 3 90° 18..19 12..13 7,3 3 180° 20..21 14..15 8,0 3 270° 22..23 16..17 8,8 PAN 4 24..25 18..19 9,6 4 90° 26..27 1A..1B 10,4 4 180° 28..29 1C..1D 11,2 4 270° 30..31 1E..1F 12 TILT size / phase see also PAN 32..63 20..3F 13..25 PAN / TILT size / phase see also PAN 64..95 40..5F 26..37 PAN / TILT (inverse) size / phase see also PAN 96..127 60..7F 38..50 Circle size / phase see also PAN 128..159 80..9F 51..62
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
15
Channel
Function
Time and Value
DMX
HEX %
Circle (inverse) size / phase see also PAN 160..191 A0..BF 63..75 Lying eight size / phase see also PAN 192..223 C0..DF 76..87 Random movement size see also PAN 224..255 E0..FF 88..100
14) Speed
Pan/Tilt relative movement 0..1 00..01 0..0,5
Pa
n/Tilt
Pan/Tilt slow – fast
Use this channel 14) also for the speed
of the movements (channel 13).
Pan Min. 660° = 200s Pan Max. 660° = 3,2s Tilt Min. 300° = 110s Tilt Max. 300° = 1,5s
2..255 02..FF 1..100
15) Zoom
Spot - Flood 10° - 26° 0…255 00…FF 0…100
4)
Max. Power-Mode vs. White-Mode
The IIMMPPRREESSSSIIOONN can use the white-balance adjustments for each individual color setting. Whether the White-Mode is used with RGB can be selected in the Normal DMX-Mode by using the Special DMX channel. If the Special channel is set to a value between DMX 0..15, the White-Mode is not used and the RGB goes for the maximum light output. If the Special channel is set to a value between DMX
16..31, the white balance is used for the RGB output. Since there is no Special DMX channel in the Compress DMX-Mode, the possibility exists to likewise select these settings also in the display menu. If the White-Mode is set to “ON”, the white-balance is activated. If the White-Mode is set to “OFF”, the RGB goes for the maximum light output (Max. Power­Mode).
5)
Color Temperature
At anytime the IIMMPPRREESSSSIIOONN can be used in a color correction mode, where by it over rides the values from the individual RGB color channels. You can choose to activate the white mode via the DMX signal using the Special channel.
6)
Special Channel functionality
The Special channel allows you to edit some fixture functionality via the DMX signal. For all operations on the Special Channel you must first ensure that both the dimmer and shutter channels are set to 0. All commands from the Special channel must be held for at least 0.5 seconds for them to take effect.
For example: To invert the tilt channel via DMX from the lighting desk, first send a value of 0 to both the dimmer and
shutter channels. Then send a value of 64-67 percent for a minimum of 0.5s, on the special channel. To return the tilt to normal operation, you need to send a value of 68-71 percent on the special
channel. It is possible to change multiple functions using the special channel in this way.
Changes from the special channel will not be saved into the default settings of the
IIMMPPRREESSSSIIOON
N
.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
16
Compress-Mode 11 DMX channels
Channel
Function
Time and Value
DMX
HEX %
1) PAN
-
coarse
0 .. 660° 3,2 s 0..255 00..FF 0..100
2) PAN
-
fine
High- Pos ... High- Pos + 2,6° (16 Bit) 0..255 00..FF 0..100
3) Tilt
-
coarse
0 .. 300° 1,5 s 0..255 00..FF 0..100
4) Tilt
-
fine
High- Pos … High- Pos + 1,2° (16 Bit) 0..255 00..F F 0..100
5) Color
Colors adjustable via RGB 0..7 00..07 0..2,5
(fixed)
Color 01 - Red 1) 8..15 08..0F 3..5,5
Color 02 - Amber 1) 16..23 10..17 6..8,5 Color 03 - Warm Yellow 1) 24..31 18..1F 9..12,5
Color 04 - Yellow 1) 32..39 20..27 13..15,5 Color 05 - Green 1) 40..47 28..2F 16..18,5 Color 06 - Turquoise 1) 48..55 30..37 19..21,5 Color 07 - Cyan 1) 56..63 38..3F 22..24,5 Color 08 - Blue 1) 64..71 40..47 25..27,5 Color 09 - Lavender 1) 72..79 48..4F 28..30,5
Color 10 - Mauve 1) 80..87 50..57 31..34,5 Color 11 - Magenta 1) 88..95 58..5F 35..37,5 Color 12 - Pink 1) 96..103 60..67 38..40,5 White - CTO Color temperature
3200K
104..111 68..6F 41..43,5
White Color temperature
5600K
112..119 70..77 44..46,5
White - CTB Color temperature
7200K
120..127 78..7F 47..49,5
Rainbow Effect Stop 2) 128 80 50 Rainbow Effect 3) slow - fast 129..223 81..DF 51..88 Rainbow Effect, random colors slow - fast 224.255 E0..FF 89..100
6) Red
Color mixing system - Red 0 - 100% 0..255 00..FF 0..100
7) Green
Color mixing system - Green 0 - 100% 0..255 00..FF 0..100
8) Blue
Color mixing system - Blue 0 - 100% 0..255 00..FF 0..100
9) Shutter
Shutter closed 0..15 00..0F 0..5,5 Random Pulse effect slow - fast 16..47 10..2F 6..18,5 Up-dimming then Shutter closing (random patterns)
slow - fast 48..79 30..4F 19..31,5
Shutter open then down-dimming (random patterns)
slow - fast 80..111 50..6F 32..43
Up-dimming then down-dimming (random patterns)
slow - fast 112..143 70..8F 44..56
Strobe effect pause 5s .. 1s 144..199 A0..C7 57..77 Strobe effect, slow - fast 1 Hz .. 10 Hz 200..239 C8..EF 78..94 Shutter open 240...249 F0..F9 95..97,5
RESET
Min. 3 Sec.
250 FA 98
Shutter open 251..255 FB..FF 99..100
10) Dimmer
Dimmer 0 - 100% 0..255 0..FF 0..100
11) Zoom
Spot - Flood 10° - 26° 0…255 00…FF 0…100
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
17
High Resolution (Extended) -Mode 14 DMX Channels
Channel
Function
Time and Value
DMX
HEX %
1) PAN
-
coarse
0 .. 660° 3,2 s 0..255 00..FF 0..100
2) PAN
-
fine
High- Pos ... High- Pos + 2,6° (16 Bit) 0..255 00..FF 0..100
3) Tilt
-
coarse
0 .. 300° 1,5 s 0..255 00..FF 0..100
4) Tilt
-
fine
High- Pos … High- Pos + 1,2° (16 Bit) 0..255 00..F F 0..100
5) Red
-
coarse
Color mixing system – Red 0 - 100% 0..255 00..FF 0..100
6) Red
-
fine
Color mixing system – Red-Low 0..255 00..FF 0..100
7) Green
-
coarse
Color mixing system – Green 0 - 100% 0..255 00..FF 0..100
8) Green
-
fine
Color mixing system – Green-Low 0..255 00..FF 0..100
9) Blue
-
coarse
Color mixing system – Blue 0 - 100% 0..255 00..FF 0..100
10) Blue
-
fine
Color mixing system – Blue-Low 0..255 00..FF 0..100
11) Shutter
Shutter closed 0..15 00..0F 0..5,5 Random Pulse effect slow - fast 16..47 10..2F 6..18,5 Up-dimming then Shutter closing (random patterns)
slow - fast 48..79 30..4F 19..31,5
Shutter open then down-dimming (random patterns)
slow - fast 80..111 50..6F 32..43
Up-dimming then down-dimming (random patterns)
slow - fast 112..143 70..8F 44..56
Strobe effect pause 5s to 1s 144..199 A0..C7 57..77 Strobe effect, slow - fast 1 Hz .. 10 Hz 200..239 C8..EF 78..94 Shutter open 240...249 F0..F9 95..97,5
RESET
Min. 3 Sec.
250 FA 98
Shutter open 251..255 FB..FF 99..100
12) Dimmer
-
coarse
Dimmer 0 - 100% 0..255 0..FF 0..100
13) Dimmer
-
fine
Dimmer - Low 0..255 0..FF 0..100
14) Zoom
Spot - Flood 10° - 26° 0…255 00…FF 0…100
1)
The predefined colors can be used as start colors for the Rainbow effect. First select a desired start
color, then activate the rainbow effect. All
IIMMPPRREESSSSIIOONNS
S
will then begin from that color and
execute the rainbow effect synchronously. Different
IIMMPPRREESSSSIIOONNS
S
can have different start colors but will still execute the rainbow effect synchronously. If you choose a color different from the ones marked with 1) in the tables above the rainbow start-color will be red.
2)
Rainbow-effect Stop will pause this function. After resuming the rainbow-effect will be continued with
the current color.
3)
The Rainbow-effect will run synchronously only if it is started from one of the predefined colors (see
also 1) before).
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
18
Locking and unlocking the Control Panel
You can lock and unlock the control panel by pressing the menu keys MODE & ENTER & UP at the same time.
Additional shortcut features when switching on the fixture
a) 1200Hz Mode (Hold down the UP- button during power ON)
After switching on, the fixture the LEDs will be operated with a Pulse Width Modulation (PWM) of 1200Hz. In addition, all standard settings will be loaded (DMX start address [001], Normal Mode).
b) 600Hz Mode (Hold down the DOWN- button during power ON)
After switching on, the fixture the LEDs will be operated with a Pulse Width Modulation (PWM) of 600Hz.
In addition, all standard settings will be loaded (DMX start address [001], Normal Mode).
c) Standard Mode (Hold down the ENTER- button during power ON)
After switching on the fixture, the DMX start address will be set to [001]. All other settings will remain unchanged.
Additional Display Indications
As a default you'll find the following additional information in the first row of the LCD display:
XX/X/XX
06 = 600Hz / 12 = 1200Hz
N = Normal Mode / C = Compressed Mode / H = High Res. Mode
N = Tilt normal / I = Tilt inverted
N = Pan normal / I = Pan inverted
55
Maintaining and Cleaning the IIMMPPRREESSSSIIOONN
The IIMMPPRREESSSSIIOONN is a low maintenance fixture. It is only necessary to clean the air inlets and outlets as well as the optical LED lenses from time to time. For safe operation it is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build up on, or within, the fixture. If they do, the fixture's light output will be significantly reduced, and damages to the fixture may occur. Regular cleaning will not only ensure the maximum light output, but will also allow the fixture to operate reliably throughout its entire life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recom­mended. Under no circumstances should alcohol or solvents be used to clean the fixture or its lenses!
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
19
5.1 Safety regulations
Disconnect the fixture from the mains power before commencing any
maintenance work!
Wait minimum 15 minutes after removing the power to allow the fixture to cool down.
5.2 Maintenance Intervals (rule-of-thumb)
The maintenance schedule of any given fixture depends on the installation environment. Hence no specific guidelines can be given. The cleaning intervals given below are suggestions, based on practical experience. We suggest that you start with these and develop your own maintenance schedule as you see the fixtures performance in your specific environment.
Maintenance Task Interval How
Cleaning of LED lenses and
optical system
weekly soft brush /lint-free cloth
Cleaning of fans and air channels monthly vacuum cleaner, airbrush, etc.
Attention:
Never let optical parts come into contact with oil or fat.
Before running the fixture wait until all parts are touch dry.
Never touch lenses with bare fingers.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
20
6 Technical Specifications
Power supply Power consumption
350 VA (Watt)
Power input
~100-240 V AC, 50-60 Hz (auto sensing input)
Fuse protection
Micro-fuse 5x20 mm, T5A
Operational Parameters Max. Ambient
Temperature
45°C / 113°F (integrated overheating switch)
Mounting Position
Any (see chapter mounting)
Lighting System - Additive Color mixing LED Type
120 x Rebel High power LED’s
Lifetime
50,000 hours
42x green LEDs, 36x blue LEDs, 42x red LEDs Wavelength optimized for maximum presentable color space
Optical System
High efficiency collimator cluster Motorized optical lens plate with a range of 10° - 26°
Shutter / Dimmer (8/16 Bit)
Strobe- Effect with variable speed between 1 - 10 flashes per second, Random-Strobe, Pulse­Effects
Continuous Dimmer 0 - 100%
DMX Control
Standard USITT DMX-512, 3 pole XLR; [+] = Pin 3, [-] = Pin 2, [Ground] = Pin 1.
Pan / Tilt (8/16 Bit) Pan- movement 660° in minimum 3.2 seconds, with position feedback Tilt- movement 300° in minimum 1.5 seconds, with position feedback Weights and Dimensions
Width
340 mm / 13.4 inches
Depth
145 mm / 5.7 inches
he
ight (head vertical)
370 mm / 14.6 inches
Weight (net)
8.0 kg / 17.6 lbs.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
21
7 Index
A
Angel of reflected beam ................................. 20
B
BGV C1............................................................ 7
C
Circumference ............................................... 19
Cleaning......................................................... 19
Compress-Mode .................................... 16, 17
D
Description of Device ....................................... 4
DIN VDE 0711-217 .......................................... 7
DMX ............................................................... 10
E
e-mail ............................................................... 1
Enter-key ....................................................... 10
Eyelets ............................................................. 7
H
Half-couplers (clamps) ..................................... 8
I
Instruction Version ........................................... 1
Internet............................................................. 1
L
LED Class 2M ................................................. 5
M
Maintenance .................................................. 19
Max. Power-Mode ........................................ 15
Menu Field ..................................................... 10
Micro-fuse ........................................................ 9
Mode-key....................................................... 10
Mounting......................................................... 6
Mounting in hanging Position .......................... 8
Mounting in sidewise Position ......................... 8
Mounting on the Floor ..................................... 7
N
Normal-Mode ............................................... 13
O
Optical parts ................................................ 19
P
Pan- Movement ............................................. 20
Power Supply ................................................ 9
Powercon ........................................................ 4
R
Rebel High-power- LEDs .............................. 20
S
Safety distance ............................................... 6
Safety Instructions .......................................... 5
Secure the Device ......................................... 9
Software Version ............................................. 1
T
Technical Specifications ............................ 20
Tilt- Movement .............................................. 20
U
Up/Down-keys .............................................. 10
V
VBG 70 ........................................................... 7
W
Warranty claims .............................................. 6
Weights and Measures ................................. 20
White-Mode .................................................. 15
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
22
Loading...