GLP Impression 120RZ RGB Instruction Manual

from software version 1.24/30 (Instruction version 1.5)
e-mail: service@glp.de
Internet: http://www.glp.de
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
2
Notes:
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
3
Table of contents
1 Description of Device.............................................................................................. 4
1.1 Safety Instructions ............................................................................................ 5
2 Preparation and Installation ................................................................................... 6
2.1 Mounting ........................................................................................................... 6
2.1.1 Mounting on the floor (upright) ............................................................. 7
2.1.2 Mounting in hanging position (head down) .......................................... 8
2.1.3 Mounting in a sideway position ............................................................ 8
2.2 Securing the Device .......................................................................................... 9
2.3 Connections ...................................................................................................... 9
2.3.1 Power Supply....................................................................................... 9
2.3.2 DMX ................................................................................................... 10
3 The Menu Field ...................................................................................................... 10
4 DMX Channel Selection (DMX Protocol) ............................................................. 13
5
5 Maintaining and Cleaning the IIMMPPRREESSSSIIOONN ....................................................... 18
5.1 Safety regulations ........................................................................................... 19
5.2 Maintenance Intervals (rule-of-thumb) ............................................................ 19
6 Technical Specifications ...................................................................................... 20
7 Index ....................................................................................................................... 21
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
4
1 Description of Device
1. Moving head (actively and passively cooled)
2. Arm with various cooling vents
3. LCD-Display/Menu (data entry)
4. Base with various connectors and Camlock mounting system
1
2
3
4
5
base side 1
6
base side 2
7891010
FUSE T4A
5. Power On/Off
6. DMX- Output (3 pole)
7. DMX- Input (3 pole)
8. Micro-fuse 5x20mm, T5A
9. Mains supply (Powercon)
10. 2x Safety eyes
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
5
1.1 Safety Instructions
The IIMMPPRREESSSSIIOONN is an advanced technology product. To guarantee smooth operation, it is necessary to follow the following instructions.
The manufacturer of this device will not take responsibility of damages through any disregard of the information in this user manual. Warranty claims will also be cancelled in the event of the system casing being opened.
1. Make sure that before powering up the fixture, the fans and air inlets are clean and not blocked by anything.
2. Before powering up the fixture, ensure that the moving head part of the fixture can rotate unhindered through its full range of movement.
3. A safety distance of at least 0.5 m to any easily flammable material (e.g. decoration material) must be adhered to.
4. Attention! Don’t touch the device during operation. Parts of the fixture can become hot and can cause injuries and / or damages.
5. The system doesn’t contain any user serviceable parts. Opening the fixture will void the manufacturers warranty.
6. Danger of burning. Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture. Pay attention to possible hot parts of the system.
7. Never look directly into the beam of light or one of the LEDs. Never use optical apertures with a distance less than 0.5 m to observe the beam of light. LED Class 2M. Not following these precautions can result in serious injury to your eyes and in particular, your retina.
Attention: LED Cla
ss 2M can cause injuries of your eyes even
without optical instruments in front of them or within a distance of less than 0.5m and short exposure time.
Avoid direct radiation to your eyes!
8. To ensure proper operation, you must also follow the installation guide described in chapter 2 of this manual. Operating the IIMMPPRREESSSSIIOONN without suitable mounting devices can increase the risk of an accident.
9. The IIMMPPRREESSSSIIOONN features a unique small and lightweight design with no specific carrying handles. Care needs to be shown when handling the fixture to ensure that no unnecessary damage should occur. Fragile areas include the LCD display and cover on one side arm and the front bezel.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
6
Pressure in these areas could result in damages which will not be covered by the standard warranty.
10. Repair-, maintenance- and installation work should only be performed by qualified or GLP certified staff. You need to pay attention to the common rules of technology that are not explicit mentioned in this manual.
11. Use only original spare parts. Any structural modification on the system will terminate all warranty claims.
12. Please keep this instruction manual for future reference.
2 Preparation and Installation
2.1 Mounting
The IIMMPPRREESSSSIIOONN is fully operational whether it hangs or is mounted to a wall. It can also be operated while standing on the floor. Keep a safety distance of
0.5 m from any easily inflammable materials (decoration etc.).
Pay attention to the regulations of: BGV C1 (former VBG 70)
and DIN VDE 0711-217.
The installation shall be done by qualified personal only.
R
R
R
-
-
-
G
G
G
-
-
-
B
B
B
GLP German Light Products GmbH
(Instruction version 1.5) / from software version 1.24/30)
7
For the various mounting positions of the IIMMPPRREESSSSIIOONN (standing on the floor, sideways or hanging) different accessories kits are available. Using any required kits, along with the standard mounting connectors on the base of the fixture, will ensure a safe and firm installation.
1x M10
(length max.16mm)
2x Camlock
quick release
fasteners
front side of the fixture
2.1.1 Mounting on the floor (upright)
To operate the IIMMPPRREESSSSIIOONN in an upright position, please use the dedicated floor-stand which ships with all original fixtures. The floor stand is mounted to the base of the fixture using the two Camlock quarter turn fasteners. Line up and engage the camlock connectors from the floor stand into the base of the fixture and turn the two fasteners 90° to lock them. Do the opposite to release them again. On both sides you'll find eyelets to pull though a fixing strap. This allows additional bracing of the floor-stand during the upright operation.