Globe Motors D31T10 Catalog Page

DC Series
AIR
2.82” ± 0.01”
(71.5 mm ± 0.3 mm)
3.15” ± 0.01”
(80 mm ± 0.3 mm)
.17” ± .04” (4.3 mm ± 1.0 mm)
LEADWIRE #24 AWG PER UL 1007
11.8” ± 0. 6” (300 mm ± 15 mm)
0.16”
(4 mm)
0.16” (4 mm)
ROTATION
1.00” ± 0.02”
(25.4 mm ± 0.5 mm)
0.17” DIA. (ø4.3 mm) 4 HOLES
3.15" Sq. x 1.00" Tubeaxial Cooling Fans Model No. D31T10
Features
• 7-blade impeller design provides:
Reduced noise
Improved performance
High efficiency
Auto restart
Low input power
Lower operating voltages
• Precision ball bearing system provides:
Longer life
Higher temperature extremes
Lower noise over time
Maximum shock and vibration resistance
• Designed to meet the rigid standards of UL, CSA, VDE, and CE.
Accessories:
Finger guards Filters Screen guard
(80 mm Sq. x 25 mm)
28-39 CFM
(13.2-18.4 L/Sec.)
General Specifications
Frame: Reinforced polybutylene plastic ((UL94V-0 flame retardant)
Impeller: Reinforced polybutylene plastic (UL94V-0 rating)
Bearings: Precision, life-lubricated ball bearings
Insulation: Class A integral ground system
rated @ 248°F (120°C)
Weight: 3.3 ozs. (95 grams)
Operating Temperature Range: 14° to 158°F
(-10° to 70°C)
Insulation Resistance: 10 megohms minimum @ 500 VDC
Dielectric Strength: 500 VAC for 60 seconds
Safety Protection: Electronic locked rotor
protected; polarity protected
Life Expectancy: 75,000 hours minimum @ 77°F (25°C)
Options: (Consult Factory) Tachometer output Locked rotor sensor output
RED LEAD IS POSITIVE (+) BLACK LEAD IS NEGATIVE (-) WHITE LEAD IS TACHOMETER/SENSOR
Globe Motors Part Number Nominal Voltage VAC
D31-B10A-04W2-100 12 6.0 / 13.8 1.32 0.11 2400 25 28 13.2
D31-B10A-04W3-100 12 6.0 / 13.8 2.04 0.17 2700 28 32 15.0
D31-B10A-04W5-100 12 6.0 / 13.8 2.76 0.23 3250 34 39 18.4
D31-B10A-05W2-100 24 10.0 / 27.6 1.68 0.07 2400 25 28 13.2
D31-B10A-05W3-100 24 10.0 / 27.6 1.92 0.08 2700 28 32 15.0
D31-B10A-05W5-100 24 10.0 / 27.6 2.88 0.12 3250 34 39 18.4
*Note: For tachometer output models, substitute “B” in part number. Part Number D31-B10"A”-04W2-100 would change to D31-B10"B”-04W2-100. Minimum order quantity may apply. For locked rotor sensor output models, substitute “C” in part number. Part Number D31-B10"
http://www.globemotors.com/d31t10.pdf
34
Voltage
Operating
Range VDC Watts Line Amps RPM Acoustic Noise dBA
A”-04W2-100 would change to D31-B10"C”-04W2-100. Minimum order quantity may apply.
Specifications subject to change without notice.
CFM
© 2002 Globe Motors
Airflow (Min.)
Liters per
Second
2.82” ± .01” (71.5 mm ± 0.3 mm)
2.82” ± .01”
(71.5 mm ± 0.3 mm)
3.07” DIA. (ø78 mm)
0.17” DIA. (ø4.3 mm) 8 HOLES
Performance at Sea LevelInstallation Guide
12.0V
12.0V
12.0V
90°
Up to 30 VDC
90°
One
Revolution
(360°)
Up to
30 VDC
1 Sec.
Typ.
Locked Rotor
State
Running
State
7 Sec.
Typ.
Approvals
3870
UL File No. E105397
CSA File No. 72877
VDE File No. 17074-2611-0701
Airflow – L/Sec.
.10
.08
.06
.04
.02
Static Pressure – In. of Water
0 5 10 15 20 25 30 35
Airflow – CFM
D31-B10A-04W2-100
Airflow – L/Sec.
2
.16
.14
.12
.10
.08
.06
.04
Static Pressure – In. of Water
.02
Airflow – L/Sec.
642
14 162 4 86 10 12
2.5
Static Pressure – MM. of Water
2.0
1.5
1.0
.5
.12
.10
.08
.06
.04
.02
Static Pressure – In. of Water
0 5 10 15 20 25 30 35 40
10 12
8
14 16 18
3.0
Static Pressure – MM. of Water
2.5
2.0
1.5
1.0
.5
Airflow – CFM
D31-B10A-04W3-100
14
16124 6 108
18
4.0
3.0
2.0
1.0
All operating specifications measured at nominal operating voltage, free air at sea level
Static Pressure – MM. of Water
24 volt performance is identical to 12 volt fan performance
Tachometer Output (Open Collector Circuit)
Locked Rotor Output (Open Collector Circuit)
© 2002 Globe Motors
0 5 10 15 20 25 30 35 40
NOTES:
Specifications subject to change without notice.
Airflow – CFM