globe fire sprinkler corporation GL5684, GL5683, GL8183 User Manual

STANDARD RESPONSE
AUTOMATIC SPRINKLERS
GL SERIES DRY TYPE
DESCRIPTION AND OPERATION
The Globe Series GL-SR/DRY Upright Sprinkler is designed for use in special applications such as freezing environments. As an example, they may be effi ciently used when connected to a wet type sprinkler system and extended into an unheated attic space. The Globe Series GL-SR/DRY Upright Sprinkler utilizes a frangible glass ampule sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water fl ows through the sprinkler and is distributed by the defl ector, in the approved discharge pattern. The heart of Globe's Series GL-SR sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fl uid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.
UPRIGHT
SERIES GL-SR/DRY
UPRIGHT
TECHNICAL DATA
See reverse side for Approvals and Specifi cations.
Temperature Ratings -
135°F (57°C), 155°F (68°C), 175°F (79°C) 200°F (93°C), 286°F (141°C)
Water Working Pressure Rating - 175 psi (12 Bars)
Maximum low temperature glass bulb rating is -67°F (-55°C)
Frame - bronze Defl ector - brass Screw - brass
Bulb Seat - brass Spring - nickel alloy Seal - tefl on
Retainer - brass Pin - stainless steel
Torsion Spring - stainless steel Orifi ce Insert - brass
Bulb - glass with glycerin solution, 5mm size
3/4”NPT or 1”NPT Outer Tube - galvanized steel pipe Inner Tube - stainless steel
SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
CLASSIFICATION
ORDINARY
INTERMEDIATE
HIGH
AVAILABLE SPRINKLER
TEMPERATURES
135°F/155°F 175°F/200°F
286°F
57°C/68°C 79°C/93°C
141°C
BULB COLOR
ORANGE/RED
YELLOW/GREEN
BLUE
N.F.P.A. MAXIMUM CEILING
TEMPERATURE
100°F 150°F 225°F
38°C 66°C
107°C
DEC 2017 GFS-530b (Formerly A-95)
STANDARD RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE UPRIGHT
SPECIFICATIONS
SIN
GL5683 5.6 (80 metric) 1”NPT GL5684 5.6 (80 metric) 3/4”NPT GL8183 8.0 (115 metric) 1”NPT
NOTE: METRIC CONVERSIONS ARE APPROXIMATE.
1
FINISHES AVAILABLE ON SPECIAL ORDER.
2
cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER.
STYLE SIN HAZARD
GL5683 ALL X X X X X X X X
Upright
GL8183 ALL X X X X X --- X X
1
SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. *FM APPROVED 155°F (68°C), 200°F (93°C), AND 286°F (141°C) ALL: ALL HAZARDS
NOMINAL
“K” FACTOR
135°F
1
(57°C)
155°F
(68°C)
THREAD
SIZE
APPROVALS
175°F
(79°C)
200°F
(93°C)
LENGTH FINISHES
cULus Variable to 48”
FM Variable to 36”
286°F
(141°C)
*FM cULus
101-92-E
Factory Bronze
White Polyester
Black Polyester
NYC DOB MEA
Chrome
DISTANCE BETWEEN
SPRINKLERS
Feet (Meters)
2
1,2
MIN.
6 (1.8) 12 (0.8)GL5684 ALL X X X X X --- X X
MIN.
OPERATING
PRESSURE
psi (Bars)
CROSS SECTION
TOP OF DEFLECTOR
"B"
4 3/4" MIN. 3/4"NPT
4 1/2" MIN. 1"NPT
3" DIA. 3/8"
FACE OF TEE FITTING
TEE FITTING
ANSI B16.3 CLASS 15 OR
ANSI 16.4 CLASS 125
GLOBE
Globe agrees to repair or replace any of its own manufactured
®
PRODUCT WARRANTY
products found to be defective in material or workmanship for a period of one year from date of shipment. For specifi c details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List).
1 1/2" MIN. DIA.
HOLE IN CEILING
IMPORTANT INSTALLATION DATA
Globe GL Series Dry Pendent Sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18”. Excessive force may distort the frame thus destroying the unit. The GL Series Dry Sprinkler must not be installed in a short radius 90° elbow. When installing in other than an iron tee, the clearances between the end of the sprin­kler and fi tting should be checked.
When installed in a wet system extending into a freezing area see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs. Please refer to our Dry Caution Sheet for further
important installation data.
ORDERING INFORMATION
SPECIFY
Quantity SIN Style Orifi ce Temperature
Finishes desired Quantity - Wrenches -
“B” Dimension - Distance from face of tting to the top of the
defl ector.
P/N 333010
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583
1-800-248-0278
DEC 2017 GFS-530b (Formerly A-95)
PRINTED U.S.A.
FAX 989-846-9231
www.globesprinkler.com
Loading...