STANDARD RESPONSE
AUTOMATIC SPRINKLERS
DESCRIPTION AND OPERATION
The Globe Series GL-SR/DRY Pendent Sprinkler is designed
for use in special applications such as freezing environments and
conditions where sediment or foreign materials might accumulate
in ordinary drop nipples.
The Globe Series GL-SR/DRY Pendent Sprinkler utilizes a frangible glass ampule sprinkler. At the ampule's rated temperature,
the sprinkler opens releasing the bulb seat, causing the inner tube
assembly to move, allowing spring assembly to pivot alongside
the inner tube. At this time, water fl ows through the sprinkler and
is distributed by the defl ector, in an approved discharge pattern.
The heart of Globe's Series GL-SR sprinkler proven actuating
assembly is a hermetically sealed frangible glass ampule that
contains a precisely measured amount of fl uid. When heat is
absorbed, the liquid within the bulb expands increasing the internal
pressure. At the prescribed temperature the internal pressure within
the ampule exceeds the strength of the glass causing the glass
to shatter. This results in water discharge which is distributed in
an approved pattern.
GL SERIES
DRY TYPE PENDENT
SERIES GL-SR/DRY
SURFACE
MOUNT
SLEEVE & SKIRT
TECHNICAL DATA
• See reverse side for Approvals and Specifi cations.
• Temperature Ratings -
135°F (57°C), 155°F (68°C), 175°F (79°C)
200°F (93°C), 286°F (141°C)
• Water Working Pressure Rating - 175 psi (12 Bars)
• Factory tested hydrostatically to 500 psi (34 Bars)
• Maximum low temperature glass bulb rating is -67°F (-55°C)
• Frame - bronze • Defl ector - brass • Screw - brass
• Bulb Seat - brass • Spring - nickel alloy • Seal - tefl on
• Retainer - brass • Pin - stainless steel
• Torsion Spring - stainless steel • Orifi ce Insert - brass
• Bulb - glass with glycerin solution, 5mm size
• 3/4”NPT or 1”NPT • Outer Tube - galvanized steel pipe • Inner Tube - stainless steel
SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
CLASSIFICATION
ORDINARY
INTERMEDIATE
HIGH
AVAILABLE SPRINKLER
TEMPERATURES
135°F/155°F
175°F/200°F
286°F
57°C/68°C
79°C/93°C
141°C
BULB COLOR
ORANGE/RED
YELLOW/GREEN
BLUE
EXTENDED
N.F.P.A. MAXIMUM CEILING
TEMPERATURE
100°F
150°F
225°F
RECESSED
38°C
66°C
107°C
DEC 2017 GFS-505b (formerly A-90)
STANDARD RESPONSE
AUTOMATIC SPRINKLERS
GL SERIES DRY TYPE
PENDENT
SPECIFICATIONS
SIN
NOMINAL
“K” FACTOR
GL5679 5.6 (80 metric) 1”NPT
GL5680 5.6 (80 metric) 3/4”NPT
GL8179 8.0 (115 metric) 1”NPT
NOTE: METRIC CONVERSIONS ARE APPROXIMATE.
1
FINISHES AVAILABLE ON SPECIAL ORDER.
2
cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER.
135°F
STYLE SIN HAZARD
Pendent
GL5679 ALL X X X X X X X X
1
(57°C)
Recessed
Pendent
1
SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS.
*PENDENT STYLE - FM APPROVED 155°F (68°C), 200°F (93°C), AND 286°F (141°C)
*RECESSED PENDENT STYLE - FM APPROVED 155°F (68°C) AND 200°F (93°C)
ALL: ALL HAZARDS
GL8179 ALL X X X X X --- X X
THREAD
SIZE
cULus Variable to 48”
FM Variable to 36”
APPROVALS
155°F
(68°C)
175°F
(79°C)
200°F
(93°C)
LENGTH FINISHES
286°F
(141°C)
*FM cULus
Factory Bronze
Chrome
White Polyester
Black Polyester
NYC-DOB
MEA
101-92-E
2
1,2
MIN.
DISTANCE
BETWEEN
SPRINKLERS
Feet (Meters)
6 (1.8)GL5680 ALL X X X X X --- X X
2 1/2" MIN. DIA.
HOLE IN CEILING
3 3/4" MIN.
4 3/4" MAX.
CROSS SECTIONS
TEE FITTING
ANSI B16.3 CLASS 15 OR
ANSI B16.4 CLASS 125
FACE OF
TEE
FITTING
"A"
1" MIN. 3/4"NPT
3/4" MIN. 1"NPT
TWO PIECE
ESCUTCHEON
FACE OF
CEILING
3 1/2" DIA.
TEE FITTING
ANSI B16.3 CLASS 15 OR
ANSI B16.4 CLASS 125
FACE OF
FITTING
2 1/2" MIN. 3/4"NPT
1 1/2" MIN. DIA.
HOLE IN CEILING
1/4"
TEE
"A"
2 1/4" MIN. 1"NPT
FACE OF
CEILING
IMPORTANT INSTALLATION DATA
Globe GL Series Dry Pendent Sprinklers should be installed in
accordance with the requirements set forth in NFPA 13. These
sprinklers are to be installed using a pipe wrench applied to
the outer tube. When this is not possible, the proper sprinkler
head wrench may be used with extreme care for lengths up to
approximately 18”. Excessive force may distort the frame thus
destroying the unit.
When installed in a wet system extending into a freezing
area see chart on Dry Caution Sheet for minimum exposed
barrel length to prevent ice plugs. Please refer to our Dry
Caution Sheet for further important installation data.
EXTENDED
TEE FITTING
ANSI B16.3 CLASS 15 OR
ANSI B16.4 CLASS 125
FACE OF
TEE
FITTING
3 1/4" MIN. 3/4"NPT
2 3/4" MIN. 1"NPT
2" MIN. DIA.
HOLE IN CEILING
2 15/16" DIA.
1 1/4" MIN.
2" MAX.
1/8"
CUP
RETAINER
RECESSED
DEC 2017 GFS-505b (formerly A-90)
SURFACE MOUNT
"A"
TWO PIECE
ESCUTCHEON
FACE OF
CEILING
TEE FITTING
ANSI B16.3 CLASS 15 OR
ANSI B16.4 CLASS 125
1 3/4" MIN. DIA.
HOLE IN CEILING
3 7/32" DIA.
2 1/2" MIN.
4" MAX.
SLEEVE & SKIRT
FACE OF
TEE
FITTING
"A"
1 3/4" MIN. 3/4"NPT
1 1/2" MIN. 1"NPT
FACE OF
CEILING
ORDERING INFORMATION
SPECIFY
• Quantity • SIN • Style • Orifi ce • Temperature • Finishes
• Quantity - Wrenches -
• Quantity Recessed Wrenches -
• Escutcheons Desired
• Quantity - Protective Caps - P/N
“A” Dimension - Distance from face of fi tting to the fi nished ceiling line
regardless of escutcheon used.
GLOBE
Globe agrees to repair or replace any of its own manufactured
®
PRODUCT WARRANTY
products found to be defective in material or workmanship for a
period of one year from date of shipment.
For specifi c details of our warranty please refer to Price List
Terms and Conditions of Sale (Our Price List).
PRINTED U.S.A.
P/N 333010
P/N 337014
327109-cap (Friction Fit Recessed)
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658
989-846-4583
1-800-248-0278
FAX 989-846-9231