Serial #:
C24GG
Conversion Kit Instructions for the
Globe Gas Countertop Griddle
Models: Manually Controlled: C24GG & C36GG
For Installation and Service on Your Gas Griddle:
1. Visit our website at www.globeslicers.com
(select the Parts / Support drop down).
2. Or call the Globe Service Department at 937-299-8625 and ask for contact
information for your local service company.
Visit our website for information on additional products available from Globe.
www.globeslicers.com
Slicers, Mixers, Countertop Cooking Equipment, Meat Choppers & Scales
- IMPORTANT NOTICE -
These instructions are for conversion of the GAS GRIDDLE. The instructions provide in this kit are for the
conversion of Natural Gas to L.P. gas and refer to the conversion of the unit and kit provided. An authorized
licensed technician must be called to preform the complete conversion of the unit. Failure to properly convert this
unit, can result in serious injury, property damage, or death and will void warranty.
O:\Service\Public\service bulletins\999240-1 Gas Conversion Manual Griddle Rev. A
Pg 1 of 4
Gas Griddle (Manually Controlled)
Conversion Kit Instructions
Do not attempt gas conversion by yourself. Gas conversion of your unit is to be
made by a certied/licensed technician. Locate an authorized Globe servicer at
www.globeslicers.com
CAUTION FOR SERVICERS: If you convert from one gas type to another, please adjust to the correct gas
pressure before use. Also, be sure to indicate the correct gas markings on all equipment tags/lables.
CONVERSION
Instructions are for conversion from Natural Gas to Propane (L.P.) on all models. The conversion should be
done before connecting the unit to the gas supply. Units are shipped from the factory equipped for use on
natural gas. Parts necessary for L.P. (liquid propane) are provided with the unit. Turn off the main gas supply
before doing any maintenance.
Convertible
regulator with
octagon cap.
Unscrew from
1. Remove the knobs and front panel.
regulator.
2. Unscrew bolts and pilot valve, then
remove the manifold.
NAT
3. Replace the orice ttings into the valve.
Note: Unit Number on side of orice
ttings.
L.P.
5. Before installing the included convertible
regulator, unscrew the octagon cap. You can read
(NAT) on the plastic insert attached to the head of
the cap; ip it over and snap back in place.
Pictured is
the plastic
insert. Pull
off insert
from octagon
cap and
reverse the
plastic insert
position so
that the L.P.
position is
attached to
the octagon
cap head.
L.P. Position
of insert.
Regulator
is now
converted to
L.P.
L.P.
L.P. Position
4. Replace the front panel and knobs
Pg 2 of 4
Rev. A O:\Service\Public\service bulletins\999240-1 Gas Conversion Manual Griddle
6. Continue with installation.