6" All Stainless
Electronic Digital Caliper
OWNER’S MANUAL
FOR YOUR SAFETY AND CARE OF THIS TOOL,
please read these instructions carefully and retain them for future use.
CARE AND MAINTENANCE
1. Keep body face clean, prevent liquid material from getting into slider to destroy electronics.
2. Face should be cleaned with a clean, dry, lint-free cloth. Lubricate body with a few drops of
3. Keep battery compartment clean and free of corrosion.
TROUBLESHOOTING
PROBLEM/
Every second 5 digits jump simultaneously
Display cannot count
Display shows 000.00 or IN 00.000
Function buttons not active
Reading error for full length is ≥ 0.1mm
No display on LCD screen
SOLUTION/
Battery voltage is under 1.45V. Remove cover and replace battery.
Faulty circuit. Remove battery, after 30 sec. put battery back into compartment.
Function buttons and sliders signal end may have shorted out. Remove the cover, put the button springs in place with rubber covers. Contact must be unobstructed.
Springs or rubber covers may be out of shape due to excessive pressing. See solution above for tips.
Sensor may have dirt or deposits in it. Remove cover and slider assembly. Blow off sensor face with clean pressurized air ≥ 51kg/cm squared), clean with a dry, lint-free cloth.
1. Poor battery contact. Check battery compartment, clean if necessary.
2. Battery voltage is under 1.3V. Replace with correct battery.
GUIDE D’UTILISATION
No. TGZ370
www.GlobalTestSupply.com
Find Quality Pro ducts Online at: sales@GlobalTestSupp ly.com
Repeatability:
0.01mm or 0.0005" Maximum measuring speed:
1.5m/sec or 60"/sec Measuring system:
Non-contact linear
CAP measuring system Display:
LCD display, minus sign "-", character in
6.35mm/0.25" height for 5 digits,
small digit "5" and "IN" sign for
inch measuring unit Battery:
One silver oxide battery 1.5V type LR44
for one year of continuous use;
low battery warning by flashing display Operating temperature:
0°C ~ +40°C Storage temperature:
-20°C ~ +70°C Influence of humidity:
Not important within 0 to 80%
of relative humidity
Auto power off
On/Metric/Inch change over (true conversion)
Off Switch
Zero setting (zero setting at any position within the measuring range)
Battery compartment cover
PRESS
SPECIFICATIONS AND FUNCTIONS
Your digital caliper was constructed with quality materials and workmanship, and will give you many years of trouble free use when cared for as described in the "Care & Maintenance" section.
CALIPER FEATURES
CALIPER APPLICATIONS
MEASURING RANGE:
0-150mm / 0 - 6"
RESOLUTION:
0.01mm / 0.0005"
Measurements of external dimensions
Measurements of internal dimensions
Measurements of depth
Differential method measurement (application of zero setting)