The following safety precautions apply to both operating and
maintenance personnel and must be observed during all phases
of operation, service, and repair of this instrument. Before
applying power, follow the installation instructions and become
familiar with the operating instructions for this instrument.
GROUND THE INSTRUMENT
To minimize shock hazard, the instrument chassis and cabinet
must be connected to an electrical ground. This instrument is
grounded through the ground conductor of the supplied, threeconductor ac power cable. The power cable must be plugged into
an approved three-conductor electrical outlet. Do not alter the
ground connection. Without the protective ground connection, all
accessible conductive parts (including control knobs) can render
an electric shock. The power jack and mating plug of the power
cable meet IEC safety standards.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not operate the instrument in the presence of ammable
gases or fumes. Operation of any electrical instrument in such an
environment constitutes a denite safety hazard.
KEEP AWAY FROM LIVE CIRCUITS
Instrument covers must not be removed by operating personnel.
Component replacement and internal adjustments must be made
by qualied service personnel. Disconnect the power cord before
removing the instrument covers and replacing components.
Under certain conditions, even with the power cable removed,
dangerous voltages may exist. To avoid injuries, always
disconnect power and discharge circuits before touching them.
globalspecialties.com1
DO NOT SERVICE OR ADJUST ALONE
Do not attempt any internal service or adjustment unless another
person, capable of rendering rst aid and resuscitation, is
present.
DO NOT SUBSTITUTE PARTS OR MODIFY THE INSTRUMENT
Do not install substitute parts or perform any unauthorized
modications to this instrument. Return the instrument to Global
Specialties for service and repair to ensure that safety features
are maintained.
WARNINGS AND CAUTIONS
A WARNING statement calls attention to an operating procedure,
practice, or condition, which, if not followed correctly, could result
in injury or death to personnel.
A CAUTION statement calls attention to an operating procedure,
practice, or condition, which, if not followed correctly, could result
in damage to or destruction of parts or the entire product.
WARNING: Do not alter the ground connection. Without the
protective ground connection, all accessible conductive parts
(including control knobs) can render an electric shock. The
power jack and mating plug of the power cable meet IEC safety
standards.
WARNING: To avoid electrical shock hazard, disconnect
power cord before removing covers. Refer servicing to qualied
personnel.
CAUTION: Before connecting the line cord to the AC mains,
check the rear panel AC line voltage indicator. Applying a line
voltage other than the indicated voltage can destroy the AC line
fuses. For continued re protection, replace fuses only with those
of the specied voltage and current ratings.
CAUTION: This product uses components which can be
damaged by electrostatic discharge (ESD). To avoid damage,
800-572-10282
be sure to follow proper procedures for handling, storing and
transporting parts and subassemblies which contain ESDsensitive components.
COMPLIANCE STATEMENTS
This product is subject to Directive 2002/96/EC of the European
Parliament and the Council of the European Union on waste
electrical and electronic equipment (WEEE), and in jurisdictions
adopting that Directive, is marked as being put
on the market after August 13, 2005, and should
not be disposed of as unsorted municipal waste.
Please utilize your local WEEE collection facilities
in the disposition of this product and otherwise
observe all applicable requirements.
7 Service and Warranty Information ........................17
1. One Year Warranty ...................................................................17
2. Calibration and Repair ..............................................................17
800-572-10284
1 Introduction
1. Overview
Global Specialties Model 1320 Triple Output High Resolution DC
Power Supply provides two variable outputs (0 – 32V / 0 – 3A)
and one xed output (5V / 3A). The variable outputs can work
independently, in series tracking, or parallel mode. Conveniently
adjust voltage and current with independent front panel knobs
and bright quad display. This power supply is ideally suited for
applications in electronic test, production, and service, where
multiple independent DC power supplies are required and bench
space is at a premium.
2. Features
z Separate 4-digit displays for voltage and current on vari-
able outputs
z Three independent outputsz Individual control of voltage and current for variable outputs z CV (constant voltage) / CC (constant current) mode opera-
tion
z LED indication for CV / CC mode z Overload indication LED for fixed output z Series tracking and parallel mode operation z Power On/Off switch on front panel z Input voltage selection on rear side (120 VAC/ 240 VAC)
2 Installation
1. Initial Inspection
This unit is tested prior to shipment. It is therefore ready for
immediate use upon receipt. An initial physical inspection should
be made to ensure that no damage has been sustained during
shipment.
Inspect the packing box on receipt for any external damage.
If any external damage is evident, remove the instrument and
visually inspect its case and parts for any damage. If damage to
globalspecialties.com5