Global Specialties certifies that all products manufactured conform
to published specifications and are free from defects in materials
and workmanship for a period of Three (3) years from the date of
delivery when used under normal operating conditions and within
the service conditions for which they were furnished.
The obligation of Global Specialties arising from a Warranty claim
shall be limited to repairing, or at its option, replacing without charge,
any product which in Global Specialties's sole opinion proves to be
defective within the scope of the Warranty.
Global Specialties must be notified in writing of the defect or
nonconformity within the Warranty period and the affected product
returned to Global Specialties within (30) days after discovery of
such defect or nonconformity.
Although Quick Servicing Guidelines are provided in the manual, the
unit doesn't contain any user serviceable parts. Global Specialties
shall have no responsibility hereunder for any defect or damage
caused by improper storage, improper installation, unauthorized
modification, neglect, inadequate maintenance, accident or for any
product which has been repaired or altered by anyone other than
Global Specialties.
EXCLUSION OF OTHER WARRANTIES
The Warranty described above is Buyer's sole and exclusive remedy
and no other warranty, whether written or oral, is expressed or
implied. Global Specialties specifically desclaims the implied warranties
of merchantability and fitness for a particular purpose. No statement,
representation, agreement, or understanding, oral or written, made
by an agent, distributor, representative, or employee of Global
Specialties, which is not contained in the foregoing Warranty will be
binding upon Global Specialties, unless made in writing and executed
by an authorized Global Specialties employee. Under no circumstances
shall Global Specialties be liable for any direct, indirect, special,
incidental, or consequential damages, expenses, losses, or delays
(including loss of profits) based on contract, tort, or any legal theory.
MODEL NO.:2001A
SR. NO.:.........................................
Contents
Section 1
SectionDescriptionPage No.
1GENERAL DESCRIPTION1
1.1Introduction1
1.2Applications1
1.3Specifications1
1.4Accessories2
2INSTALLATION3
2.1Inspection3
2.2Power Requirements3
2.3Safety Considerations3
3OPERATION4
3.1Front Panel Controls4
3.2Rear Panel Controls5
3.3Precautions6
3.4Operating Procedure6
4MAINTENANCE8
4.1Maintenance8
4.2Servicing8
5CIRCUIT DIAGRAMS9
6MANUAL CHANGES14
General Description
1.1INTRODUCTION
The Model 2001A is a very useful instrument for any test
requirement. It is a easy to use, compact 0.2Hz to 200KHz
Function Generator.
This manual contains information pertaining to the specifications,
installation and operation of 200KHz Function Generator
Model 2001A.
1.2APPLICATIONS
The function generator can be used to test the frequency
response of low frequency amplifiers, attenuators, filters, etc
besides being a source of the most commonly used waveforms.
TTL output is provided to synchronise other circuitry or for
direct use with logic circuits. SWEEP IN terminal can be used
to sweep the output frequency using external voltage.
1.3SPECIFICATIONS
FUNCTION GENERATOR
Waveform:Sine, Triangle, Square.
Frequency Range:0.2Hz to 200KHz in 6 decade ranges.
Frequency:±5% of the setting at 10Hz, 100Hz,
Indication Accuracy1KHz & 10KHz spot.
Function Out:1mV to 10V p-p (with 4 selectable
ranges; into open circuit).
TTL Out:Standard TTL level squarewave.
Rise/Fall Time : <25ns.
DC Offset:±5V DC into open circuit.
AC (signal) + DC (offset) =
±10V p-p open circuit
±5V p-p into 600 ohms.
Level Fine:20dB variable (approx.).
1
Level Ranges:1mV - 10mV p-p,
10mV - 100mV p-p,
100mV - 1V p-p &
1V p-p - 10V p-p.
Sine wave Distortion :<2% upto 100KHz (<1% typical)
<3% above 100KHz.
Squarewave:Time symmetry : ±1.5% (typical <1%)
Rise/Fall Time : <100ns
(into 600 ohms +20pf).
Triangle Linearity:Better than 1%.
Sweep Input:0 to +10V DC.
Sweep Range:100:1 approx. (For external input at
SWEEP IN).
Input Impedance:30K ohms approx.
GENERAL
Power:115 / 230V AC ±10%,47- 63Hz.
Consumption:5VA.
Dimensions (mm):245 (W) x 76 (H) x 185 (D) mm
(approx.).
9½” x 3” x 7¼”
Weight:2 Kg. / 4.5 lbs (approx.).
1.4ACCESSORIES
1. BNC to BNC-1
2. Operation Manual-1
3. Power Cord-1
Section 2
Installation
2.1INSPECTION
The instrument is packed in a corrugated sheet box. As soon
as the unit is received, carefully open the box and inspect it
for any damage that may have occurred during transit. Save
all packing material. If any damage is found, notify the
carriers and our authorised representatives or ourselves
immediately. Also check whether all the specified accessories
are present.
2.2POWER REQUIREMENTS
The instrument operates over a nominal 115V ±10%, 60Hz or
230V AC ±10% 50Hz AC line. A power cord has been provided
to connect the instrument to proper source.
2.3SAFETY CONSIDERATIONS
2.3.1 Prior to applying power to the instrument, ensure that earth is
extended to the mains socket.
Intentional interruption of the grounding system, by use of
two-wire plug adapters or two wire extension cords must be
considered an unsafe practice.
2.3.2 Be sure that only correct fuse with proper V & A ratings is
installed for replacement purposes. INCORRECT FUSE
RATING CAN RESULT IN FIRE &/OR SERIOUS DAMAGE
OR HARM TO HUMAN LIFE & PROPERTY.
23