Know your Power Supply read the Manual prior to Operation.
TABLE OF CONTENTS
SECTION PARTICULARS PAGE NO.
1GENERAL INFORMATION1
2INSTALLATION2
3OPERATING INSTRUCTIONS3
4PART LIST4
CAUTION NOTE
!
This power supply has been designed and tested in
accordance with the safety requirements for electrical
equipment for measurement,control and laboratory use.
This manual contains important information and
warnings which have to be followed by the user for his
safety as well as safe operation of the unit. This power
supply operates according to safety Class 'I' Standards.
SECTION - 1
GENERAL INFORMATION
DESCRIPTION :
This simple AC/DC power source is designed specifically
for use in educational institutions. It can be used to demonstrate the concept of alternating and non-alternating voltages. It can also be used for simple experiments using
lamps, resistances, etc. The unit has been provided with
Voltmeter and Ammeter for AC / DC Voltage and current
readings
SPECIFICATIONS :
AC Voltage :
PCB ComponentsZ-DPM/02
=======================================================================
Ref DesignatorValue
=======================================================================
IC
IC1ICL7107 CPL
VR1TL431
FND
DS1GREEN FND COMMON ANODE
DS2GREEN FND COMMON ANODE
DS3GREEN FND COMMON ANODE
CONNECTORS
J13PIN, 2.54MM MALE
J34PIN, 2.54MM MALE
R412H555 SPADE CONNECTOR.
Output voltage
No Load: 0V to 30V (nom)
Full Load: 0V to 25V ±2V
Output current: 5A max
Output protection: 5A Circuit Breaker
DC Voltage :
No Load: 0V to 40V
Full Load: 0V to 25V ± 2V
Output voltage: 0V to 25V (nom)
Output current: 5A max
Output protection: 6A Circuit Breaker
DPM V/A Selection: 2Pole/2Way Push Sw.
Output Voltage: 3 Digit LED Display (Green)
Output Current: 3 Digit LED Display (Green)
General :
Input power: 115V / 230VAC,60 Hz,single phase
Input Fuse 115/230V : 2A /3A, 250V Slow Blow
Dimensions: 235mm x 155mm x 295 mm.
( W x H x D ) approx.
Weight: 10.0 Kg. approx.
GENERAL
=======================================================================
Ref DesignatorValue
=======================================================================
SWITCHES
C11µF, 50V, ELE
C21µF, 50V, ELE
C30.1µF, 50V, CD
C447µF, 50V, ELE
C4*0.1µF, 50V, CD
C510µF, 50V, ELE
C6470µF, 30V, ELE
C710µF, 50V, ELE
C80.1µF, 50V, CD
C90.1µF, 50V, CD
C10220µF, 30V, ELE
C10*0.1µF, 50V, CD
C1110µF, 50V, ELE
C120.1µF, 50V, CD
ICs
U1UA7805
U2UA7812
U3UA7905
SECTION - 2
INSTALLATION
INITIAL INSPECTION :
As soon as the 1315D variable AC/DC source is unpacked,
inspect for any damages that may have occured during
transit. Save all packing material until inspection
is complete. If damage is found, notify the carriers
immediately. Our authorised representative also should be
notified.
PHYSICAL CHECK :
This check should confirm that there are no broken knobs.
The cabinet and panel surfaces should be free of dents.
C1220pF, 50V, CD
C30.01µF, 50V, CD
C40.47µF, 50V, MP
C50.1µF, 50V, MP
C60.1µF, 50V, MP
C710µF, 50V, ELE
C7*0.1µF, 50V, MP
C80.1µF, 50V, CD
C910µF, 50V, ELE
C100.1µF, 50V, CD
5
The 1315D variable AC/DC source is shipped ready for
bench operation. It is necessary only to connect the
instrument to a rated input voltage 115V or 230VAC / 60 Hz
/ 5A source of power. To select the correct input voltage
select tap selection switch at the rear panel and it is ready
for operation.
INPUT POWER REQUIREMENTS :
The 1315D variable AC/DC source may be operated
continuously from a 115V or 230V AC / 60 Hz power sourc
with the help of input selector switch at the rear panel.
REPACKING FOR SHIPMENT :
To ensure safe shipment of the 1315D variable AC/DC
source, it is recommended that the package designed
for the instrument be used. The original packing
material is reusable.
2
SECTION - 3
OPERATING INSTRUCTIONS
SECTION - 4
PART LIST
a) 1315D as AC supply :
Set output voltage to 0V by turning the variable control to
minimum position ( Anti Clockwise ).
Set Power ON switch to apply input power. Adjust the voltage
control to obtain the required output voltage. The variable
control is a coarse control to adjust the output voltage with
in 0-30V Connect the load at the AC output. The output
voltage will be 25V after connecting 5A Load. The total load
current should not exceed 5A for continuous operation.
In case of sustained overload, the overload trip operates to
isolate the power supply from the load. When the overload
is removed, the trip switch can be reset.
b) 1315D as DC supply :
Set output voltage to 0V by turning the variable control to
minimum position ( Anti Clockwise ).
Set Power ON switch to apply input power. Adjust the voltage
control to obtain the required output voltage at the Red &
Black Terminals. The variable control is a coarse control to
adjust the output voltage with in 0-40V. Connect the load
at the DC output terminals. The output waveform is fullwave rectified DC output. The output voltage will be 25V
approx after connecting 5A Load. The total load current
should not exceed 5 A for continuous operation.
In case of sustained overload, the overload trip operates to
isolate the power supply from the load. When the overload
is removed, the trip switch can be reset.
c) Panel Meter :3 Digit DPM will read voltage & current of
AC/DC outputs by selecting the Push Switch on the front
panel to monitor respective Voltage & Current.
d) Indications :
Power ON will be indicated by illuminated ON/OFF Switch.