Wall Mounted Filtered Water Cooler
Model 761217
WARNING
• Keep compressor in upright position for 24 hours
before water connections and initial power-on. Failure
to do so will void warranty.
• For indoor commercial use only.
• All installation work must be performed by authorized
service personnel.
• Two or more people are recommended to lift and install
the unit.
• To avoid the risk of property damage and/or personal
injury, mount the unit to a flat finished wall surface with
adequate support.
• Check local codes for plumbing requirements prior
to installation.
• Prior to initial installation, install a shut-off valve (not
included) from the water supply.
• Thoroughly flush all water lines and fittings of all foreign
matter before connecting to the cooler. Failure to do so
will void warranty.
• Check for any leaks before initial operation.
• DO NOT attempt to repair or replace any part of your
appliance unless it is specifically recommended in
this manual. All other services should be referred to a
qualified technician.
Read this manual thoroughly prior to
installation, operation or maintenance.
Keep these instructions in a safe location
for future reference. For questions, visit
globalindustrial.com or contact Customer
Service at 1-800-645-2982.
• For use with clean, clear potable drinking water only.
• Shut-off water supply during installation to reduce risk
of water damage.
• Ensure proper ventilation by allowing appropriate
clearance of housing louvers to the wall on each side
of the cooler, as specified in rough-in guide.
•
NEVER wire the compressor directly to an electrical supply.
• DO NOT allow children to play with the appliance.
• Interior of unit may contain sharp edges. Wear gloves
when handling or servicing unit.
•
Failure to follow installation instructions will void warranty.
Note: These fixtures are intended for indoor commercial
use only. Do not expose to freezing temperatures.
The grounding of electrical equipment to water lines is
a common procedure. This grounding may be in the
building or occur away from the building. This grounding
can cause electric feedback into the water cooler
creating an electrolysis which creates a metallic taste or
causes the water metal content to increase. Connect to
water supply using non-conductive materials.
1
052120
Wall Mounted Filtered
Water Cooler
User's Manual
Risk of Electrical Shock
• Disconnect power before servicing unit.
• Electric supply must be identical in voltage, cycle and
phase to those specified in the specifications below.
Unit must be plugged into a GFCI outlet.
• Always pull the plug – not the cord – when disconnecting
from the outlet
• DO NOT use if the power cord is worn or damaged.
Power cords should only be replaced by qualified
service technicians using genuine replacement parts.
• Check local codes for electrical requirements.
• DO NOT disassemble or modify unit.
• Use Global Industrial filters only – Model 670336
Voltage/Hertz 115V/60Hz
*Chilling Capacity 8.0 GPH
Full-Load Amps 1.9 Amps
Rated Watts 185 W
Filter Capacity 4750 or 3000 Gallons
Quick-Fill Rate 1.0 GPM
Water Flow Laminar
Overall Dimensions 18
Certification
* At 46° - 54° (F) against ambient air temperature of 77° (F)
1
/
"W x 16"D x 19
8
UL399 and CAN/CSA 22.2 No. 120
ADA Compliant
ANSI/NSF 372
ANSI/NSF 42 and 53 (Filter)
5
/
"H
16
Package Contents:
Box 1 - 761214 Top Assembly for Water Fountain
Stainless Steel Pan
Note:
• Prior to installation, consult with local, state, and federal
codes for proper mounting height.
• All installation and service should only be performed by
authorized personnel.
• Dimensions shown below comply with ADA requirements
at time of printing.
• Allow 4" minimum clearance on both sides to allow for
proper ventilation through cabinet louvers.
• Thoroughly flush all water lines and fittings of all foreign
matter before connecting to the Cooling System.
Failure to do so will void warranty.
Required Tools:
1. Safety Glasses
2. Safety Gloves
3. Electric Drill
4. Phillips Head Screwdriver
5. Flathead Screwdriver
6. Tape Measure
7. Pencil
8. Level Device
9. (8) 75-lb. Capacity Flat Head Wall Anchors
(appropriate for your wall type)
10. (8) Flat Head Anchor Screws
WARNING
• Review manual thoroughly and verify rough-ins before
installation. Keep these instructions in a safe location
for future reference.
• Keep compressor in upright position for 24 hours
before water connections and initial power-on. Failure
to do so will void warranty.
• It is recommended to assemble this product on a
tabletop or bench.
• Fixture must be mounted to a flat finished industry
standard wall surface. The wall surface must have
adequate support to secure the fixture, with the
addition of wall anchors (not included) if required.
• All receptacles must be wired to a GFCI protected
circuit. Fixture must be earth grounded per National
Electric Code (NEC).
• Inspect fixture and all parts for damage.
Not Pictured:
Hardware Bag
Mounting Stencil
Box 2 - 761212 Cooling System for Water Fountain
Mounting Bracket
(attached to rear)
Water Filter
Cooling System
2
Wall Mounted Filtered
Water Cooler
User's Manual
Check local codes for plumbing requirements
prior to installation.
3