Global Industrial 761217 User Manual

globalindustrial.ca
User's manual Manual del usuario Manuel de l'utilisateur
Customer Service
US: 1-800-645-2986
US: 1-800-645-2986
Service à la clientèle
Canada: 888-645-2986
Wall Mounted Filtered Water Cooler
Model 761217
WARNING
Keep compressor in upright position for 24 hours before water connections and initial power-on. Failure to do so will void warranty.
• For indoor commercial use only.
• All installation work must be performed by authorized service personnel.
• Two or more people are recommended to lift and install the unit.
• To avoid the risk of property damage and/or personal injury, mount the unit to a flat finished wall surface with adequate support.
• Check local codes for plumbing requirements prior to installation.
• Prior to initial installation, install a shut-off valve (not included) from the water supply.
• Thoroughly flush all water lines and fittings of all foreign matter before connecting to the cooler. Failure to do so will void warranty.
• Check for any leaks before initial operation.
• DO NOT attempt to repair or replace any part of your appliance unless it is specifically recommended in this manual. All other services should be referred to a qualified technician.
Read this manual thoroughly prior to installation, operation or maintenance. Keep these instructions in a safe location for future reference. For questions, visit globalindustrial.com or contact Customer Service at 1-800-645-2982.
• For use with clean, clear potable drinking water only.
• Shut-off water supply during installation to reduce risk of water damage.
• Ensure proper ventilation by allowing appropriate clearance of housing louvers to the wall on each side of the cooler, as specified in rough-in guide.
NEVER wire the compressor directly to an electrical supply.
• DO NOT allow children to play with the appliance.
• Interior of unit may contain sharp edges. Wear gloves when handling or servicing unit.
Failure to follow installation instructions will void warranty.
Note: These fixtures are intended for indoor commercial use only. Do not expose to freezing temperatures. The grounding of electrical equipment to water lines is a common procedure. This grounding may be in the building or occur away from the building. This grounding can cause electric feedback into the water cooler creating an electrolysis which creates a metallic taste or causes the water metal content to increase. Connect to water supply using non-conductive materials.
1
052120
Wall Mounted Filtered
Water Cooler
User's Manual
Risk of Electrical Shock
• Disconnect power before servicing unit.
• Electric supply must be identical in voltage, cycle and phase to those specified in the specifications below. Unit must be plugged into a GFCI outlet.
• Always pull the plug – not the cord – when disconnecting from the outlet
• DO NOT use if the power cord is worn or damaged. Power cords should only be replaced by qualified service technicians using genuine replacement parts.
• Check local codes for electrical requirements.
• DO NOT disassemble or modify unit.
• Use Global Industrial filters only – Model 670336
Voltage/Hertz 115V/60Hz
*Chilling Capacity 8.0 GPH
Full-Load Amps 1.9 Amps
Rated Watts 185 W
Filter Capacity 4750 or 3000 Gallons
Quick-Fill Rate 1.0 GPM
Water Flow Laminar
Overall Dimensions 18
Certification
* At 46° - 54° (F) against ambient air temperature of 77° (F)
1
/
"W x 16"D x 19
8
UL399 and CAN/CSA 22.2 No. 120 ADA Compliant ANSI/NSF 372 ANSI/NSF 42 and 53 (Filter)
5
/
"H
16
Package Contents:
Box 1 - 761214 Top Assembly for Water Fountain
Stainless Steel Pan
Note:
• Prior to installation, consult with local, state, and federal codes for proper mounting height.
• All installation and service should only be performed by authorized personnel.
• Dimensions shown below comply with ADA requirements at time of printing.
• Allow 4" minimum clearance on both sides to allow for proper ventilation through cabinet louvers.
• Thoroughly flush all water lines and fittings of all foreign matter before connecting to the Cooling System. Failure to do so will void warranty.
Required Tools:
1. Safety Glasses
2. Safety Gloves
3. Electric Drill
4. Phillips Head Screwdriver
5. Flathead Screwdriver
6. Tape Measure
7. Pencil
8. Level Device
9. (8) 75-lb. Capacity Flat Head Wall Anchors
(appropriate for your wall type)
10. (8) Flat Head Anchor Screws
WARNING
• Review manual thoroughly and verify rough-ins before installation. Keep these instructions in a safe location for future reference.
• Keep compressor in upright position for 24 hours before water connections and initial power-on. Failure to do so will void warranty.
• It is recommended to assemble this product on a tabletop or bench.
• Fixture must be mounted to a flat finished industry standard wall surface. The wall surface must have adequate support to secure the fixture, with the addition of wall anchors (not included) if required.
• All receptacles must be wired to a GFCI protected circuit. Fixture must be earth grounded per National Electric Code (NEC).
• Inspect fixture and all parts for damage.
Not Pictured:
Hardware Bag Mounting Stencil
Box 2 - 761212 Cooling System for Water Fountain
Mounting Bracket (attached to rear)
Water Filter
Cooling System
2
Wall Mounted Filtered
Water Cooler
User's Manual
Check local codes for plumbing requirements prior to installation.