USER MANUAL
MODEL# 761210:Retrofit Toilet/Urinal Flush Sensor Kit for Royal
and Regal Sloan
MODEL# 761211:Retrofit Toilet/Urinal Flush Sensor Kit for Zurn
PRODUCT STRUCTURE
Chrome-Plated M eta l Casting Cover
Operates on 4 AA Alkaline
Batteries
Latching Solenoid Operator
Manual Mechanical Override
Button:
allows user to flush the
valve during a power outage
Operating Pressure:
15 to 100 PSI
Infrared Sensor:
Accurate,stable perf ormanc e,
even in the sunlight or any light.
Adjustable sensor range:
15~32 inch.
Adjustable Flush Volume
Closet:1.28/1.6/2.4 GPF
Urinal:0.25/0.5/1.0/1.5 GPF
Interchangeable from Closet
to Urinal Valve
Dual Flush
Light Flush (1.1 GPF):
if user is in detection zone for 60
seconds or less
Standard Flush (1.6 GPF):
if user is in detection zone for more
than 60 seconds
Easy Installation and
maintenance
Retrofits for Royal,
Regal (Sloan) and Z6000
Manual Flush Valve (Zurn)
Diaphragm Type:
self-cleaning mechan ism, preven ts clogging,
reduces maintenance and ensures stable flow
1
SPECIFICATION
Product Retrofit Kit for Water Closet Flush Valve
Casing Material Chrome Plated
Power Supply 4 AA Alkaline Batteries
Power Consumption 3W
Battery Life 3 Years (Based on 3,000 cycles per month)
Sensing Distance
Adjustable 1-9/16"~3-5/32" (40 - 80cm)
Minimum Detection Time 5 Seconds
Flush Delay Time 3 Seconds
Operating Pressure 15 ~ 100 PSI
Flush Volume Adjustable 1.28 / 1.6 / 2.4 GPF
Sanitary Flush Flushes after every 24 hours of non-use
Light Flush :1.1 GPF
Dual Flush
Standard Flush :1.6 GPF
Product Retrofit Kit for Urinal Flush Valve
Casing Material Chrome Plated
Power Supply 4 AA Alkaline Batteries
Power Consumption 3W
Battery Life 3 Years (Based on 3,000 cycles per month)
Sensing Distance
Adjustable 1-9/16"~3-5/32" (40 - 80cm)
Minimum Detection Time 5 Seconds
Flush Delay Time 1 Second
Operating Pressure 15 ~ 100 PSI
Flush Volume Adjustable 0.25 / 0.5 / 1.0 / 1.5 GPF
Sanitary Flush Flushes after every 24 hours of non-use
2
HOW TO USE
2. When user leaves the sensing area, the unit automaticly flushes the
A. Closet Flush Valve
1. A continuous invisible light beam is emitted from the sensor. As the user
enters the beam's effective range (1-9/16"~3-5/32" ) more than 5 seconds,
the output circuit continues in a "hold" mode for as long as the user remains
within the effective range of the sensor.
2. When the user steps away from the Valve, the circuit initiates a flushing
cycle to flush the fixture. The circuit then automatically resets and is ready the
next user.
B. Urinal Flush Valve
1. A continuous invisible light beam is emitted from the sensor. As the user
enters the beam's effective range (1-9/16"~3-5/32" ) more than 5 seconds,
the output circuit continues in a "hold" mode for as long as the user remains
within the effective range of the sensor.
3
ur
.