Global Industrial 761211, 761210 User Manual

USER MANUAL
MODEL# 761210Retrofit Toilet/Urinal Flush Sensor Kit for Royal
and Regal Sloan
MODEL# 761211Retrofit Toilet/Urinal Flush Sensor Kit for Zurn
PRODUCT STRUCTURE
Chrome-Plated M eta l Casting Cover
Operates on 4 AA Alkaline Batteries
Manual Mechanical Override Button
allows user to flush the valve during a power outage
Operating Pressure
15 to 100 PSI
Infrared Sensor Accurate,stable perf ormanc e,
even in the sunlight or any light. Adjustable sensor range
15~32 inch.
Adjustable Flush Volume Closet1.28/1.6/2.4 GPF
Urinal0.25/0.5/1.0/1.5 GPF
Interchangeable from Closet to Urinal Valve
Dual Flush
Light Flush (1.1 GPF) if user is in detection zone for 60
seconds or less Standard Flush (1.6 GPF)
if user is in detection zone for more than 60 seconds
Easy Installation and maintenance
Retrofits for Royal, Regal (Sloan) and Z6000 Manual Flush Valve (Zurn)
Diaphragm Type: self-cleaning mechan ism, preven ts clogging, reduces maintenance and ensures stable flow
1
SPECIFICATION
Standard Flush
1.6 GPF
Product Retrofit Kit for Water Closet Flush Valve Casing Material Chrome Plated Power Supply 4 AA Alkaline Batteries Power Consumption 3W Battery Life 3 Years (Based on 3,000 cycles per month) Sensing Distance
Adjustable 1-9/16"3-5/32" (40 - 80cm) Minimum Detection Time 5 Seconds Flush Delay Time 3 Seconds Operating Pressure 15 ~ 100 PSI Flush Volume Adjustable 1.28 / 1.6 / 2.4 GPF Sanitary Flush Flushes after every 24 hours of non-use
Light Flush 1.1 GPF Dual Flush
Standard Flush 1.6 GPF
Product Retrofit Kit for Urinal Flush Valve Casing Material Chrome Plated Power Supply 4 AA Alkaline Batteries Power Consumption 3W Battery Life 3 Years (Based on 3,000 cycles per month) Sensing Distance
Adjustable 1-9/16"3-5/32" (40 - 80cm) Minimum Detection Time 5 Seconds Flush Delay Time 1 Second Operating Pressure 15 ~ 100 PSI Flush Volume Adjustable 0.25 / 0.5 / 1.0 / 1.5 GPF Sanitary Flush Flushes after every 24 hours of non-use
2
HOW TO USE
2. When user leaves the sensing area, the unit automaticly flushes the
inal
A. Closet Flush Valve
1. A continuous invisible light beam is emitted from the sensor. As the user enters the beam's effective range (1-9/16"3-5/32" ) more than 5 seconds, the output circuit continues in a "hold" mode for as long as the user remains within the effective range of the sensor.
2. When the user steps away from the Valve, the circuit initiates a flushing cycle to flush the fixture. The circuit then automatically resets and is ready the next user.
B. Urinal Flush Valve
1. A continuous invisible light beam is emitted from the sensor. As the user enters the beam's effective range (1-9/16"3-5/32" ) more than 5 seconds, the output circuit continues in a "hold" mode for as long as the user remains within the effective range of the sensor.
3
ur
.