Global Industrial 713170 User Manual

Safety Data Sheet
According to Hazard Communication Standard (29 CFR 1910.1200)
Li-ion Battery Pack
Issue date: 10/28/2020 EFSH20101680-CG-01
1. Product and Company Identification
Material name
CAS #
Product code
Technical Description
Product use
Manufacturer/Supplier
Supplier(Manufacturer):
Address:
Contact person(E-mail):
Telephone:
Fax:
Emergency telephone Number:
2. Hazards identification
GHS classification
Physical hazards
Health hazards
Environmental hazards
GHS label elements
Hazard Pictograms
Signal word
Hazard statement
Precautionary statement
Prevention
Response
Storage
Disposal
Other hazards
Li-ion Battery Pack
See section 3
B209
25.2V 161.28Wh 6400mAh
Not available
SUZHOU KING SUN CLEANING EQUIPMENT CO., LTD
29HONGXI ROAD,NEW DISTRICT ,215151,SUZHOU ,CHINA
Xushuo(xushuo@eup.cn)
0512-68313759
Not classified
Not classified
Not classified
No hazard pictogram is used.
No signal word is used.
Not applicable.
Not applicable.
Not applicable.
Not applicable.
Not applicable.
Not available.
3. Composition / Information on Ingredients
Components CAS# Percent
Aluminum Foil 7429-90-5 2-10%
Nickel compound proprietary 0-80%
Manganese compound proprietary 0-15%
Cobalt compound proprietary 0-15%
Styrene-Butadiene-Rubber N/A <1%
Polyvinylidene Fluoride (PVDF) 24937-79-9 <5%
Copper Foil 7440-50-8 2-10%
Carbon (proprietary) 7440-44-0 10-30%
Electrolyte proprietary 10-20%
steel, Nickel and inert materials N/A Remainder
4.
First Aid Measures
First aid procedures
Eurofins Product Testing Service (Shanghai) Co., Ltd No.395 West Jiangchang Road, Jing’an District, Shanghai, China
1 / 7
Eye contact
Skin contact
Inhalation
Ingestion
Notes to physician
Safety Data Sheet
According to Hazard Communication Standard (29 CFR 1910.1200)
Li-ion Battery Pack
Not a health hazard. If exposure to internal materials within cell due to damaged
outer casing, the following actions are recommended: Rinse eyes with water for 15
minutes and seek medical attention.
Not a health hazard. If exposure to internal materials within cell due to damaged
outer casing, the following actions are recommended: Wash area thoroughly with
soap and water and seek medical attention.
Not a health hazard. If exposure to internal materials within cell due to damaged
outer casing, the following actions are recommended: Leave area immediately and
seek medical attention.
If swallowed, obtain medical attention immediately. If exposure to internal
materials within cell due to damaged outer casing, the following actions are
recommended: Drink milk/water and induce vomiting; seek medical attention.
Treat symptoms.
5. Fire Fighting Measure
Flammable properties
Extinguishing media
Suitable extinguishing media
Unsuitable extinguishing media Not available.
Firefighting equipment/instructions
Hazardous combustion products
6. Accidental Release Measures
Personal precautions
Environmental precautions
Methods for cleaning up
7. Handling and Storage
Handling
Storage
Not available.
Use extinguishing media suitable for the materials that are burning.
Wear self contained breathing apparatus for fire fighting if necessary.
If cells are opened, hydrogen fluoride and carbon monoxide may be released.
Use personal protective equipment. Ensure adequate ventilation.
Do not let product enter drains.
On Land
Place material into suitable containers and call local fire/police department.
In Water
If possible, remove from water and call local fire/police department.
No special protective clothing required for handling individual cells.
Store in a cool, dry place.
8. Exposure Controls / Personal Protection
Occupational exposure limits
US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000)
Components Type Value Form
Aluminum Foil (CAS 7429-90-5) PEL 5 mg/m3
Copper Foil (CAS 7440-50-8) PEL 1 mg/m3
US. OSHA Table Z-3 (29 CFR 1910.1000)
Components Type Value Form
Aluminum Foil (CAS 7429-90-5) TWA 5 mg/m3
Eurofins Product Testing Service (Shanghai) Co., Ltd No.395 West Jiangchang Road, Jing’an District, Shanghai, China
Respirable fraction.
15 mg/m3
0.1 mg/m3
15 mg/m3
Total dust.
Dust and mist.
Fume.
Respirable fraction.
Total dust.
2 / 7
Safety Data Sheet
According to Hazard Communication Standard (29 CFR 1910.1200)
Li-ion Battery Pack
50 mppcf
15 mppcf
Carbon (proprietary) (CAS
7440-44-0)
TWA 5 mg/m3
15 mg/m3
US. ACGIH Threshold Limit Values
Components Type Value Form
Aluminum Foil (CAS 7429-90-5) TWA 1 mg/m3 Respirable fraction.
Copper Foil (CAS 7440-50-8) TWA 1 mg/m3
0.2 mg/m3
US. NIOSH: Pocket Guide to Chemical Hazards
Components Type Value Form
Aluminum Foil (CAS 7429-90-5) TWA 5 mg/m3
5 mg/m3
10 mg/m3
Carbon (proprietary) (CAS
TWA 2.5 mg/m3 Respirable.
7440-44-0)
Copper Foil (CAS 7440-50-8) TWA 1 mg/m3
0.1 mg/m3
Biological limit values
Appropriate engineering controls:
No biological exposure limits noted for the ingredient(s).
Handle in accordance with good industrial hygiene and safety practice. Wash hands
before breaks and at the end of workday.
Individual protection measures, such as personal protective equipment:
Eye / face protection
Skin protection
Not required beyond safety practices of employer.
Gloves are not required for handling of cells. Steel toed shoes recommended for large
container handling.
Respiratory protection
General hygiene
considerations
Not required during normal operations. SCBA required in the event of a fire.
Wash hands, forearms and face thoroughly after handling chemical products, before
eating, smoking and using the lavatory and at the end of the working period.
Total dust.
Respirable fraction.
Respirable fraction.
Total dust.
Dust and mist.
Fume.
Respirable.
Welding fume or pyrophoric
powder.
Respirable.
Dust and mist.
Fume.
9. Physical & Chemical Properties
Appearance
Physical state
Form
Color
Odor
Odor threshold
pH
Vapor pressure
Vapor density
Solid
Solid
Not available
Not available
Not available
Not available
Not available
Not available
Boiling point Not available
Melting point/Freezing point
Solubility (water)
Density
Eurofins Product Testing Service (Shanghai) Co., Ltd No.395 West Jiangchang Road, Jing’an District, Shanghai, China
Not available
Insoluble
Not available
3 / 7
Safety Data Sheet
According to Hazard Communication Standard (29 CFR 1910.1200)
Li-ion Battery Pack
Flash point
Partition coefficient
Flammability limits in air, upper, %by volume
Flammability limits in air, lower, % by volume
Auto-ignition temperature
VOC
Percent volatile
Molecular Formula
Molecular Weight Not available
Other data
Viscosity
Dissociation constant
10. Chemical Stability & Reactivity Information
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Reactivity
Chemical stability
Conditions to avoid
Incompatible materials None during normal operation. Avoid exposure to heat, open flame, and
Hazardous decomposition products
Possibility of hazardous reactions
11. Toxicological Information
Toxicokinetics, metabolism and distribution:
Non-human toxicological data:
The substance is stable under normal storage and handling conditions.
Material is stable under normal conditions.
Incompatible materials. Avoid exposure to heat and open flame. Do not puncture,
crush or incinerate.
corrosives.
None during normal operating conditions. If cells are opened, hydrogen fluoride
and carbon monoxide may be released.
No hazardous reactions known.
Not available
Information on toxicological effects:
Acute toxicity:
LD50(Oral, Rat):
LD50(Dermal, Rabbit):
LC50(Inhalation, Rat):
Skin corrosion/Irritation:
Serious eye damage/irritation: Not classified
Respiratory or skin sensitization:
Germ cell mutagenicity:
Carcinogenicity:
Reproductive toxicity:
STOT- single exposure:
STOT-repeated exposure:
Aspiration hazard:
Not available
Not available
Not available
Not classified
Not classified
Not classified
Not classified
Not classified
Not classified
Not classified
Not classified
12. Ecological Information
Toxicity:
Acute toxicity Time Species Method Evaluation Remarks
LC50 N/A 96h Fish OECD 203 N/A N/A
Eurofins Product Testing Service (Shanghai) Co., Ltd No.395 West Jiangchang Road, Jing’an District, Shanghai, China
4 / 7
According to Hazard Communication Standard (29 CFR 1910.1200)
EC50 N/A 48h Daphnia OECD 202 N/A N/A
EC50 N/A 72h Algae OECD 201 N/A N/A
Persistence and degradability:
Bioaccumulative potential:
Mobility in soil:
Results of PBT&vPvB assessment:
Other adverse effects:
Safety Data Sheet
Li-ion Battery Pack
Not available.
Not available.
Not available.
Not available.
Not available.
13. Disposal Considerations
Disposal instructions
Contaminated packaging
14. Transport Information
With regard to transport of the product, the following regulations are cited and considered:
The International Civil Aviation Organization (ICAO) Technical Instructions,
The International Air Transport Association (IATA) Dangerous Goods Regulations
The International Maritime Dangerous Goods (IMDG) Code,
US Hazardous Materials Regulations 49 CFR(Code of Federal Regulations) Sections 173- 185 Lithium batteries and cells,
The UN Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria 38.3 Lithium batteries,
If those lithium-ion batteries are packed with or contained in an equipment, then it is the responsibility of the shipper to ensure that the
consignment are packed in compliance to the latest edition of the IATA Dangerous Goods Regulations Section II of either Packing
Instruction 966 or 967 in order for that consignment to be declared as NOT RESTRICTED (non-hazardous/non-Dangerous). If those
lithium-ion batteries are packed with or contained in an equipment, UN No. is UN3481
Each cell or battery is of the type proven to meet the requirements of each test in the UN Manual of Tests and Criteria, Part III, subsection
38.3;
DOT
Basic shipping requirements:
UN number
Proper shipping name
Hazard class
Packing group
Environmental hazards
IATA
UN number UN 3480, UN3481
UN proper shipping name
Transport hazard class(es)
Packing group
Environmental hazards
IMDG
Dispose of contents/container in accordance with
local/regional/national/international regulations.
Since emptied containers may retain product residue, follow label warnings even
after container is emptied.
UN 3480, UN3481
Lithium ion batteries; Lithium ion batteries contained in equipment or Lithium ion
batteries packed with equipment.
9
-
No
Lithium ion batteries; Lithium ion batteries contained in equipment or Lithium ion
batteries packed with equipment.
9
-
No
Eurofins Product Testing Service (Shanghai) Co., Ltd No.395 West Jiangchang Road, Jing’an District, Shanghai, China
5 / 7
UN number
UN proper shipping name
Transport hazard class(es)
Packing group
Environmental hazards
Safety Data Sheet
According to Hazard Communication Standard (29 CFR 1910.1200)
Li-ion Battery Pack
UN 3480, UN3481
Lithium ion batteries; Lithium ion batteries contained in equipment or Lithium ion
batteries packed with equipment.
9
-
No
15. Regulatory Information
US federal regulations
Toxic Substances Control Act (TSCA)
TSCA Section 12(b) Export Notification (40 CFR 707, Subpt. D)
Not regulated.
CERCLA Hazardous Substance List (40 CFR 302.4)
Copper Foil (CAS 7440-50-8) Listed.
SARA 304 Emergency release notification
Not regulated.
OSHA Specifically Regulated Substances (29 CFR 1910.1001-1053)
Not regulated.
Superfund Amendments and Reauthorization Act of 1986 (SARA)
SARA 302 Extremely hazardous substance
Not listed.
SARA 311/312 Hazardous chemical
SARA 313 (TRI reporting)
Chemical name CAS number % by wt.
Aluminum Foil 7429-90-5 2-10%
Copper Foil 7440-50-8 2-10%
Other federal regulations
Clean Air Act (CAA) Section 112 Hazardous Air Pollutants (HAPs) List
Not regulated.
Clean Air Act (CAA) Section 112(r) Accidental Release Prevention (40 CFR 68.130)
Not regulated.
Safe Drinking Water Act (SDWA)
US state regulations
California Proposition 65
Not listed.
US. California. Candidate Chemicals List. Safer Consumer Products Regulations (Cal. Code Regs, tit. 22, 69502.3, subd.
(a))
Aluminum Foil (CAS 7429-90-5)
Copper Foil (CAS 7440-50-8)
No
Not regulated.
16. Other Information
HMIS®ratings
NFPA ratings
Eurofins Product Testing Service (Shanghai) Co., Ltd No.395 West Jiangchang Road, Jing’an District, Shanghai, China
Health: 0
Flammability: 1
Physical hazard: 0
Health: 0
6 / 7
Disclaimer
Issue date
Safety Data Sheet
According to Hazard Communication Standard (29 CFR 1910.1200)
Li-ion Battery Pack
Flammability: 1
Instability: 0
The information in the sheet was written based on the best knowledge and
experience currently available.
11-03-2020
Eurofins Product Testing Service (Shanghai) Co., Ltd No.395 West Jiangchang Road, Jing’an District, Shanghai, China
7 / 7
Loading...