1. Introduction
1.1 General Description
This document introduces in detail the function of the 695800 Thermal Imaging System, the specific operation steps and precautions.
1.2 Processor Requirements
above
Operating System: Windows7/10 and above (64-bit)Resolution: 1600 x 900 and aboveHard Disk: solid state disk,128GB or aboveMemory: 4G or aboveWired Network Card: GbE (gigabit Ethernet)
1.3 Environmental Requirements
1) For indoor use only with an ambient temperature range of 60°F to 90°F (16°C to 32°C), and a relative humidity less than 70%.
2) Keep the camera away from entrance doors to avoid the temperature difference between inside and outside. Avoid direct sunlight or any light from directly facing the lens.
3) Before temperature screening, turn on the camera and allow up to 30 minutes for it to warm up.
4) The effective temperature measuring distance between the camera and personnel is 6-1/2 ft. to 10 ft. The optimum temperature measuring distance is 7.2 ft.
5) The elevated temperature detection alarm can be set according to user preference. It is generally recommended to set the alarm temperature to 99°F (37.3°C).
1.4 Precautions
1) Read entire manual and follow all instructions and precautions before assembly, operation or maintenance. Not doing so will void warranty. For additional questions or concerns, contact Global Industrial Customer Service at 1-800-645-2986 or visit www.globalindustrial.com.
2) Only use product-specific adapters and cables included with the thermal imaging system.
3) DO NOT face camera directly at high-intensity temperature sources such as the sun or lasers.
4) DO NOT plug or unplug any cables when the product is connected to the power supply.
5) DO NOT exceed 18 straight hours of continuous operation. At this point, it is then recommended to shut
down and allow machine to rest for 8 hours before using again.
6) DO NOT touch the optical window surface with your hands or any corrosive or sharp objects.
7) When stains appear on the surface of the optical window, it should be cleaned by professionals;
8) DO NOT disassemble, alter or modify the machine with consent from Global Industrial.
9) DO NOT remove or damage factory labels on the product.
2. Device Position
3. Assembly Instructions
Watch "English installation video.mp4" video for hardware assembly and installation instructions.
4. Software Installation
4.1 Computer Configuration
4.1.1 Resolution
Set the screen resolution to 1920 ×1080
Figure 4-1 Resolution Setting
4.1.2 Power & Sleep Setting
Figure 4-2 Power sleep mode settings
4.1.3 Device Installation
1) Take off the dovetail foundation on top of the tripod and turn the screw to the most prominent position.
2) Match the dovetail foundation with the base part of IR (infrared) camera. Then fix the camera to the tripod, make sure the locking mechanism is fastened.
3) Plug in the network cable and the power adapter into the IR camera. Remove the lens cover of the camera. Turn on the power switch and the indicator light will turn on. On initial use, allow the camera to warm up for at least 30 minutes.
4) Match the dovetail foundation with the blackbody. Then attach the blackbody to the tripod, make sure the locking mechanism is fastened.