Global Industrial 670283 User Manual

SAFETY DATA SHEET
Issue Date 07-Nov-2018 Revision Date 23-Apr-2018 Version 1
1. PRODUCT AND COMPANY IDENTIFICATION
Product identifier Product Name
Other means of identification Product Code Synonyms
Details of the supplier of the safety data sheet Company Name
Emergency telephone number Emergency Telephone
Classification
Anti-Foam Additive
Global Industrial 2505 Mill Center Parkway Buford GA 30518 (888) 978-7759
Chemtrec (US &Canada) 800-424-9300 Chemtrec (outside US & Canada) 703-527-3887
2. HAZARDS IDENTIFICATION
OSHA Regulatory Status
This product has been classified in accordance with the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200)
Acute toxicity - Oral Not classified Acute toxicity - Dermal Not classified Skin sensitization Category 1
Label elements
Emergency Overview
Warning
Hazard statements
May cause an allergic skin reaction
Appearance White Emulsion Physical state Liquid Odor Pleasant Precautionary Statements - Prevention
Avoid breathing dust/fume/gas/mist/vapors/spray Contaminated work clothing should not be allowed out of the workplace Wear protective gloves
_____________________________________________________________________________________________
Page 1 / 7
670283 Anti-Foam Additive Revision Date 23-Apr-2018
_____________________________________________________________________________________________
Precautionary Statements - Response
Specific Treatment (See Section 4 on the SDS) IF ON SKIN: Wash with plenty of soap and water If skin irritation or rash occurs: Get medical advice/attention IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing Call a POISON CENTER or doctor/physician if you feel unwell IF SWALLOWED: Rinse mouth. DO NOT induce vomiting Drink plenty of water Immediately call a POISON CENTER or doctor/physician
Precautionary Statements - Disposal
Disposal should be in accordance with applicable regional, national and local laws and regulations
Hazards not otherwise classified (HNOC) Other Information
Unknown Acute Toxicity 7% of the mixture consists of ingredient(s) of unknown toxicity
3. COMPOSITION/INFORMATION ON INGREDIENTS
Chemical Name CAS No. Weight-% Trade Secret
2-(2-methoxypropoxy)propano 34590-94-8 1-5 *
*The exact percentage (concentration) of composition has been withheld as a trade secret.
4. FIRST AID MEASURES
First aid measures Skin Contact
Eye contact
Inhalation Ingestion
Self-protection of the first aider Most important symptoms and effects, both acute and delayed Symptoms
Indication of any immediate medical attention and special treatment needed Note to physicians
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician. Wash off immediately with soap and plenty of water.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. If symptoms persist, call a physician.
Remove to fresh air. If symptoms persist, call a physician. Do NOT induce vomiting. Drink plenty of water. Immediate medical attention is not required.
Rinse mouth. Use personal protective equipment as required.
Any additional important symptoms and effects are described in Section 11: Toxicology Information.
May cause sensitization of susceptible persons.
5. FIRE-FIGHTING MEASURES
Suitable extinguishing media
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Unsuitable extinguishing media
Specific hazards arising from the chemical
In the event of fire and/or explosion do not breathe fumes. May cause sensitization by inhalation and skin contact. Thermal decomposition can lead to release of irritating and toxic gases and vapors.
Caution: Use of water spray when fighting fire may be inefficient.
670283 Anti-Foam Additive Revision Date 23-Apr-2018 _____________________________________________________________________________________________
Explosion data Sensitivity to Mechanical Impact Sensitivity to Static Discharge
None. None.
Protective equipment and precautions for firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures Personal precautions
Use personal protective equipment as required. Avoid contact with eyes and skin.
Environmental precautions Environmental precautions
Do not allow into any storm sewer drains, lakes, streams, ponds, estuaries, oceans or other surface water bodies. Should not be released into the environment. Dispose of according to all local city, state and federal rules and regulations.
Methods and material for containment and cleaning up Methods for containment Methods for cleaning up
Prevent further leakage or spillage if safe to do so. Soak up with inert absorbent material. Pick up and transfer to properly labeled containers.
After cleaning, flush away traces with water. Prevent product from entering drains.
7. HANDLING AND STORAGE
Precautions for safe handling Advice on safe handling
Conditions for safe storage, including any incompatibilities Storage Conditions
Incompatible materials
Ensure adequate ventilation, especially in confined areas. Use personal protective equipment as required.
Keep out of the reach of children. Keep container tightly closed. Keep containers tightly closed in a cool, well-ventilated place.
None known based on information supplied.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters Exposure Guidelines
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
2-(2-methoxypropoxy)propano
34590-94-8
NIOSH IDLH Immediately Dangerous to Life or Health
Other Information
Appropriate engineering controls Engineering Controls Individual protection measures, such as personal protective equipment
.
STEL: 150 ppm
TWA: 100 ppm
S*
TWA: 600 mg/m
(vacated) TWA: 100 ppm
(vacated) TWA: 600 mg/m
(vacated) STEL: 150 ppm
(vacated) STEL: 900 mg/m
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962 (11th Cir., 1992).
Showers, Eyewash stations & Ventilation systems.
TWA: 100 ppm
(vacated) S*
S*
3
3
3
IDLH: 600 ppm TWA: 100 ppm
TWA: 600 mg/m
STEL: 150 ppm
STEL: 900 mg/m
3
3
Loading...
+ 4 hidden pages