SAFETY DATA SHEET
Issue Date 05-Nov-2018 Revision Date 16-May-2018 Version 1
1. PRODUCT AND COMPANY IDENTIFICATION
Product identifier
Product Name
Other means of identification
Product Code
Synonyms
Details of the supplier of the safety data sheet
Company Name
Emergency telephone number
Emergency Telephone
Classification
Air Conditioning Coil & Fin Cleaner
670282
None
Global Industrial
2505 Mill Center Parkway
Buford GA 30518
(888) 978-7759
Chemtrec (US &Canada) 800-424-9300
Chemtrec (outside US & Canada) 703-527-3887
2. HAZARDS IDENTIFICATION
OSHA Regulatory Status
This product has been classified in accordance with the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200)
Acute toxicity - Oral Not classified
Acute toxicity - Dermal Not classified
Skin corrosion/irritation Category 3
Label elements
Emergency Overview
Warning
Hazard statements
Causes mild skin irritation
Appearance Clear Blue Physical state Liquid Odor Cherry
Precautionary Statements - Response
Immediately call a POISON CENTER or doctor/physician
Specific Treatment (See Section 4 on the SDS)
IF ON SKIN: Wash with plenty of soap and water
If skin irritation occurs: Get medical advice/attention
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing
Call a POISON CENTER or doctor/physician if you feel unwell
IF SWALLOWED: Rinse mouth. DO NOT induce vomiting
Drink plenty of water
Immediately call a POISON CENTER or doctor/physician
Precautionary Statements - Disposal
Disposal should be in accordance with applicable regional, national and local laws and regulations
_____________________________________________________________________________________________
Page 1 / 7
670282 Air Conditioning Coil & Fin Cleaner Revision Date 16-May-2018
_____________________________________________________________________________________________
Hazards not otherwise classified (HNOC)
Other Information
Unknown Acute Toxicity 1% of the mixture consists of ingredient(s) of unknown toxicity
3. COMPOSITION/INFORMATION ON INGREDIENTS
Chemical Name CAS No. Weight-% Trade Secret
2-Hydroxypropanoic acid 79-33-4 1-5 *
Surfactant Blend Proprietary 1-5 *
PROPRIETARY Proprietary 1-5 *
*The exact percentage (concentration) of composition has been withheld as a trade secret.
4. FIRST AID MEASURES
First aid measures
Skin Contact
Eye contact
Inhalation
Ingestion
Most important symptoms and effects, both acute and delayed
Symptoms
Indication of any immediate medical attention and special treatment needed
Note to physicians
Wash off immediately with soap and plenty of water. If skin irritation persists, call a
physician.
Rinse thoroughly with plenty of water for at least 15 minutes, lifting lower and upper eyelids.
Consult a physician.
Remove to fresh air.
Clean mouth with water and drink afterwards plenty of water.
Any additional important symptoms and effects are described in Section 11: Toxicology
Information.
Treat symptomatically.
5. FIRE-FIGHTING MEASURES
Suitable extinguishing media
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Unsuitable extinguishing media
Specific hazards arising from the chemical
No Information available.
Caution: Use of water spray when fighting fire may be inefficient.
Explosion data
Sensitivity to Mechanical Impact
Sensitivity to Static Discharge
Protective equipment and precautions for firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full
protective gear.
None.
None.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Personal precautions
Ensure adequate ventilation, especially in confined areas.
670282 Air Conditioning Coil & Fin Cleaner Revision Date 16-May-2018
_____________________________________________________________________________________________
Environmental precautions
Environmental precautions
Methods and material for containment and cleaning up
Methods for containment
Methods for cleaning up
Do not allow into any storm sewer drains, lakes, streams, ponds, estuaries, oceans or other
surface water bodies. Should not be released into the environment. Dispose of according to
all local city, state and federal rules and regulations.
Prevent further leakage or spillage if safe to do so.
Pick up and transfer to properly labeled containers.
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on safe handling
Conditions for safe storage, including any incompatibilities
Storage Conditions
Incompatible materials
Handle in accordance with good industrial hygiene and safety practice.
Keep containers tightly closed in a dry, cool and well-ventilated place.
None known based on information supplied.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Appropriate engineering controls
Engineering Controls
Individual protection measures, such as personal protective equipment
Eye/face protection
Skin and body protection
Respiratory protection
General Hygiene
Showers, Eyewash stations & Ventilation systems.
Safety glasses or chemical splash goggles.
Wear chemical resistant gloves. Wear suitable protective clothing.
If exposure limits are exceeded or irritation is experienced, NIOSH/MSHA approved
respiratory protection should be worn. Positive-pressure supplied air respirators may be
required for high airborne contaminant concentrations. Respiratory protection must be
provided in accordance with current local regulations.
Handle in accordance with good industrial hygiene and safety practice.
9. PHYSICAL AND CHEMICAL PROPERTIES
Information on basic physical and chemical properties
Physical state
Appearance
Color
Odor
Odor threshold
Property Values Remarks • Method
pH
Specific Gravity
Viscosity
Melting point/freezing point
Flash point
Boiling point / boiling range
Evaporation rate
Liquid
Clear Blue
Blue
Cherry
No Information available
2.5 - 4.0
1.011
< 25 cP @ 25°C
No Information available
> 205 °F
No Information available