Global Industrial 641527, 641528, 641529 User Manual

Page 1/7
Safety Data Sheet
Printing date :Aug.20th,2019 Revision: Aug.20th,2019
1 Identification of the substance/preparation and of the company/undertaking
·
Product details
·
·
Registration number:
·
Application of the substance / the preparation:
To provide power, mainly for remote control, flashlight and so on.
·
Manufacturer/Supplier:
WUXI NORAN BATTERY CO., LTD. Zhetangbang village, QQqianzhou town,huishan district,wuxi, jiangsu, China. Tel: +86-510-83381858 Fax: +86-510-83399778
·
Further information obtainable from:
·
Information in case of emergency:
Andrew MP: 13376218678
·
Email:
·
Reference Number:
enquiries@live.cn
Not available.
WUXI NORAN BATTERY CO., LTD.
OGCSH090122-1; SH9000538-1/CHEM
2 Hazards identification
·
Hazard description:
N Dangerous for the environment
·
Information concerning particular hazards for human and environment:
The product has to be labelled due to the calculation procedure of the "General Classification guideline for preparations of the EU" in the latest valid version. R 50/53 Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.
·
Classification system:
The classification is according to the latest editions of the EU-lists, and extended by company and literature data.
3 Composition/information on ingredients
·
Chemical characterization
·
Description:
Mixture of substances listed below with nonhazardous additions. For the wording of the listed risk phrases refer to section 16.
·
Dangerous components:
CAS: 1313-13-9 EINECS: 215-202-6 EU Number: 025-001-00-3
CAS: 7440-66-6 EINECS: 231-175-3
CAS: 1310-58-3 EINECS: 215-181-3 EU Number: 019-002-00-8
CAS: 7782-42-5 EINECS: 231-955-3
·
Non-dangerous component:
CAS: 12597-69-2 Steel
CAS: 7440-50-8 EINECS: 231-159-6
CAS: 32131-17-2 Nylon-66
manganese dioxide Xn; R 20/22 35-40 %
Zinc powder - zinc dust (pyrophoric) F, N; R 15-17-50/53 10-22 %
potassium hydroxide C, Xn; R 22-35 5-9 %
Graphite Xi; R 36/37 2.5- 3 %
copper
15-20%
2-4 %
1- Q2 %
(Contd. on page 2)
EU
DR
Safety Data Sheet
Trade name:Alkaline Battery LR6 LR03 LR20 LR14 6LR61
·
Remark :
manganese dioxide (CAS No. 1313-13-9) Synonym: MnO
Zinc (CAS No. 7440-66-6) Synonym: Zn
potassium hydroxide (CAS No. 1310-58-3) Synonym: KOH
copper (CAS No. 7440-50-8) Synonym: Cu
4 First aid measures
Page 2/7
Revision:Aug.20th,2019Printing date: Aug.20th,2019
(Contd. of page 1)
·
General information:
·
After inhalation:
·
After skin contact:
·
After eye contact:
·
After swallowing:
Immediately remove any clothing soiled by the product.
Supply fresh air; consult doctor in case of complaints.
Immediately rinse with water. Rinse opened eye for several minutes under running water. Then consult a doctor. If symptoms persist consult doctor.
5 Fire-fighting measures
, sand, extinguishing powder. Do not use water.
·
Suitable extinguishing agents:
·
Protective equipment:
CO
Wear fully protective suit. Wear self-contained respiratory protective device. Do not inhale explosion gases or combustion gases.
6 Accidental release measures
·
Person-related safety precautions:
Wear protective equipment. Keep unprotected persons away. Ensure adequate ventilation. Use respiratory protective device against the effects of fumes/dust/aerosol. Keep away from ignition sources.
·
Measures for environmental protection:
Do not allow product to reach sewage system or any water course. Inform respective authorities in case of seepage into water course or sewage system. Do not allow to enter sewers/ surface or ground water.
·
Measures for cleaning/collecting:
Do not flush with water or aqueous cleansing agents
7 Handling and storage
·
Handling
·
Information for safe handling:
Ensure good ventilation/exhaustion at the workplace. Keep away from heat and direct sunlight. Open and handle receptacle with care.
·
Information about fire - and explosion protection:
Protect against electrostatic charges. Keep ignition sources away - Do not smoke. Keep respiratory protective device available.
·
Storage
·
Requirements to be met by storerooms and receptacles:
Store in a cool location. Store only in the original receptacle.
DR
(Contd. on page 3)
EU
Page 3/7
Safety Data Sheet
Printing date:Aug.20th,2019 Revision: Aug.20th,2019
Trade name:Alkaline Battery LR6 LR03 LR20 LR14 6LR61
(Contd. of page 2)
·
Information about storage in one common storage facility:
Store away from foodstuffs. Store away from flammable substances.
·
Further information about storage conditions:
Keep container tightly sealed. Store in cool, dry conditions in well sealed receptacles.
8 Exposure controls/personal protection
·
Additional information about design of technical facilities:
·
Ingredients with limit values that require monitoring at the workplace:
No further data; see item 7.
1313-13-9manganese dioxide (35-40%)
WEL (Great Britain)
5 mg/m³ as Mn
PEL (USA)
Short-term value:: C 5 mg/m³ as Mn
REL (USA)
Short-term value:: 3 mg/m³ Long-term value:: 1 mg/m³ as Mn
TLV (USA)
0,2 mg/m³ as Mn
1310-58-3potassium hydroxide (5-9%)
WEL (Great Britain) REL (USA) TLV (USA)
Short-term value:: 2 mg/m³ 2 mg/m³ Short-term value:: C 2 mg/m³
7440-50-8copper (2-4,0%)
WEL (Great Britain)
Short-term value:: 2** mg/m³ Long-term value:: 0,2* 1** mg/m³ *fume **dusts and mists (as Cu)
PEL (USA)
1* 0,1** mg/m³ as Cu *dusts and mists **fume
REL (USA)
Short-term value:: II (2)** mg/m³ Long-term value:: 1* 0,1 R** mg/m³ as Cu *dusts and mists **fume
TLV (USA)
Short-term value:: (0,1)** mg/m³ Long-term value:: (1)* (02)** mg/m³ *dusts and mists; **fume; as Cu
7782-42-5Graphite (2,5-3%)
PEL (USA) REL (USA)
15 mppcf mg/m³ 2,5* mg/m³ *respirable dust
TLV (USA)
2 R mg/m³ all forms except graphite fibers
·
DNELs:
·
PNECs:
·
Additional information:
·
Personal protective equipment
·
General protective and hygienic measures:
Not available. Not available.
The lists valid during the making were used as basis.
Keep away from foodstuffs, beverages and feed. Immediately remove all soiled and contaminated clothing. Wash hands before breaks and at the end of work.
·
Respiratory protection:
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.
(Contd. on page 4)
EU
DR
Loading...
+ 4 hidden pages