GENERAL SAFETY INSTRUCTIONS
Read instructions carefully before assembling or installing your fan. It is important that you observe all safety information to help prevent personal injury and/or property damage.
TO REDUCE THE RISK OF SHOCK, THIS FAN
MUST BE INSTALLED WITH A GENERAL USE
ISOLATING WALL CONTROL/SWITCH.
1.Installation work and electrical wiring should be done by qualified person only in accordance with all applicable codes and standards.
2.All wiring and installation procedures must satisfy National Electrical Codes (ANSI/ NFPA 70) and Local Codes.
3.Disconnect the fan from the power supply before any servicing.
4.Use this fan only in the manner intended by the manufacturer. This fan is intended for permanent installation and to be used for circulation only.
5.The secondary support cable included with the fan must be properly connected.
6.To reduce the risk of personal injury, do not bend the blade mount when installing the mount onto the motor, installing the blades onto the mount, or cleaning the fan.
7.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
8.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
9.Do not insert foreign objects in between rotating fan blades.
10.Ceiling fans without guards are to be installed at least 10 feet above the floor with adequate clearance between blades and adjacent walls, furnishings, etc.
11.When mounted in cathedral ceiling, blade tips should be at least 1 foot from the angled roof line or air turbulence may cause the fan to sway.
12.The supporting beam must be capable of holding at least 90 pounds (or the weight of the fan plus any accessories that might be added).
Chemical Burn Hazard. Keep batteries away from children. This product contains a lithium button/coin cell battery. If a new or used lithium button/coin cell battery is swallowed or enters the body, it can cause severe internal burns and can lead to death in as little as 2 hours. Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
-The cells shall be disposed of properly, including keeping them away from children.
-Even used cells may cause injury.
To reduce the risk of personal injury, do not bend
the blade bracket (flange or blade holder) when
installing the brackets, balancing the blades, or
cleaning the fan. Do Not Insert Foreign Objects In
Between Rotating Fan Blades.
13.For supply connections, if the conductor of a fan is identified as a grounded conductor, then it should be connected to a grounded conductor power supply. If the conductor of a fan is identified as an ungrounded conductor, then it should be connected to an ungrounded conductor power supply. If the conductor of a fan is identified for equipment grounding, then it should be connected to an equipment grounding conductor.
14.To reduce the risk of fire or electric shock, do not use this fan with other types of solid-state speed control devices.
SPECIFICATION
Model 293047 293048 293049
Size(inch) 72 96 108
Voltage(V) 120 120 120
Frequency(Hz) 60 60 60
Wattage(W) 47.5 47.5 48
AMPS(A) 0.68 0.68 0.7
RPM 145 92 81
Airflow(CFM) 11,290 17,018 19,448
Downrod Dimensions 26mmx6” 26mmx6” 26mmx6”
Blade Pitch
Speeds 6 6 6
Net Weight(lbs) 21.6 24.7 25.6
Certification UL,cUL UL,cUL UL,cUL
User’s Manual
3
REF QTY DESCRIPTION
1 1 Mounting Bracket
2 2 Downrod/Ball Joint Assembly
3 2 Canopy
4 1 Canopy Cover
5 1 Downrod Cover
6 1 Motor Assembly
7 1 Fan Blade Holder
8 6 Fan Blade
9 6 Fan Blade Cap
10 6 Fan Blade Screw Cover
11 1 Bottom Cover
1 2
3
4
65
8
7
11
9
10
PARTS OF THE FAN
Industrial DC Ceiling Fan
User’s Manual
4
H1
H2
H3
H4
H5 H6
H8
H9
H14
H7
REF QTY DESCRIPTION
H1 2 10#-32x3/4 Screw
H2 3 Wire Caps
H3 1
3/16x2” Wood Screw
+Ф5.5xФ25xT1.5 Lock Washer(For cUL Only)
H4 1 Mounting Pin
H5 28 M5x10mm Long Screw
H6 1 Cotter Pin
H7 7 1/4-20x3/8” Long Screw
H8 7 Ф6 Lock Washer
H9 10 M4x6mm Long Screw
H10 10 Ф4 Plain Washer
H11 38 Ф5 Lock Washer
H12 10 M5x8mm Long Screw
H13 1 Remote and Remote Bracket
H14 1 Battery
PARTS OF THE FAN
H12
H11
H10
H13
Industrial DC Ceiling Fan
Model D H
293047 72 425mm
293048 96 425mm
293049 108 425mm
Dimensions(inch)