Global Industrial 293018 User Manual

Blower HeElectric
Models: 653561 653560 6535
653558 653562 246067
g
globalindustrial.ca
Customer Service
US: 1-800-645-2986
Servicio de atención al Clien
México: 01.800.681.6940
DE CFDistribucion Industrial Globales S DE RL
ectives d’assemblageDir
Service à la clientèle
Canada: 888-645-2986
THESE
050117
1
READ & SAVE
INSTRUCTIO
Wall Mount Models: 653566 653567 653568
653569 246068
Washdown Rated Stainless Steel
Pedestal and Wall Mounted Fan
READ & SAVE THESE
INSTRUCTIONS
Models:293018 293019 293020
and 293021
User’s Manual
2
GENERAL SAFETY INSTRUCTIONS
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Do not use the fan if any part is damaged or missing. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Do not depend on any switch as the sole means of
disconnecting power when installing or servicing the
fan. Failure to do so may result in fatal electrical shock.
1. Ensure that the power source conforms to the electrical requirements of the fan.
2. Installed in accordance with the United States National Electrical Code (NEC) and all applicable local codes and ordinances. This work must be done by a qualified electrician, using copper wire only.
3. For the power cord connection, the appropriate wire Type SJTW should be used.The specifications are not lower than NO.18AWG,rated minimum 300 V, 80C.Cord length minimum
1.5 m and 1.8 m long for USL and CNL respectively, maximum
7.6 m and 3 m for USL and CNL .
4. Do not kink the cord or allow it to contact oil, grease, chemicals, hot surfaces, or sharp or abrasive objects.
5. This fan is to be operated ONLY with its OSHA compliant guards in place to prevent persons and/or objects from contacting the revolving propeller. Any other use voids warranty and may create unsafe conditions.
6. Fan is intended for general air circulation ONLY. It must NOT be used in potentially dangerous locations such as flammable, explosive or chemical-laden atmospheres. Do not attach ductwork to the fan.
Do not insert fingers or foreign objects into the fan. Do
not block or tamper with the fan in any manner while it is
in operation.
To reduce the risk of fire or electric shock, do not use this fan with any solid state speed control device. This fan must be grounded, when using a plug cable, must be a three-pin plug. This fan is suitable for wet location. When Installed In A GFCI Protected Branch Circuit.The fan is a double voltage device and it must be wired and grounded according to the wiring diagram.If the plug does not fit into the outlet, contact a qualified electrician.
Do not attempt to bypass this safety feature.
SPECIFICATION
Model 293018 293019 293020 293021
Size(inch) 24 30 24 30
Voltage(V) 115/230 115/230 115/230 115/230
Frequency(Hz) 60 60 60 60
Wattage(W) 310/305 310/305 310/305 310/305
AMPS(A) 2.85/1.55 2.85/1.55 2.85/1.55 2.85/1.55
RPM 1050/1060 1050/1060 1050/1060 1050/1060
Airflow(CFM) 7200 9600 7200 9600
Net Weight(KG) 21.5 23.7 25.9 28.3
Certification UL&cUL UL&cUL UL&cUL UL&cUL
Washdown Rated Stainless Steel
Pedestal and Wall Mounted Fan
7. Fan motor is equipped with an automatically resetting control circuit that will disconnect power if the motor overheats. Always unplug fan before removing guard, as motor may restart unexpectedly.
8. Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair.
9. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
10.Disconnect the fan when moving it from one location to another.
11.Make sure the fan is on a stable, flat surface while it is in operation.
12.Disconnect the fan when removing the guards for cleaning.
Do not touch motor. May be hot enough to cause injury.
Unplug prior to servicing unit.
IMPORTANT: Surges in electrical power or excessive heat could
cause the fan to automatically shut off. Should this occur, wait approximately 15 minutes for the fan to resume operation.
NOTE: Air circulator is not to be used in unattended areas.
The fan must be grounded and installed in A GFCI
Protected Branch Circuit. Improper connection may
create the risk of electrocution. Use of such adapters is
prohibited in Canada.
Washdown Rated Stainless Steel
Pedestal and Wall Mounted Fan
User’s Manual
3
PARTS OF THE FAN
Contains
REF QTY DESCRIPTION
1 1 Front Fan Guard
2 1 Blade
3 1 Rear Fan Guard
4 1 Motor Assembly
5 1 Upper Column
6 1 Lower Column
7 1 Base Assembly
Washdown Rated Stainless Steel Pedestal Fan Model: 293020 and 293021
Washdown Rated Stainless Steel Wall Mounted Fan Model: 293018 and 293019
Contains
REF QTY DESCRIPTION
1 1 Front Fan Guard
2 1 Blade
3 1 Rear Fan Guard
4 1 Motor Assembly
5 1 Wall Mounting Bracket Assembly
1
4
2
3
5
6
7
4
5
3
2
1
User’s Manual
4
Washdown Rated Stainless Steel
Pedestal and Wall Mounted Fan
PRE-INSTALLATION: All necessary screws are installed in the associate part for ease of tracking for customer. Please use the following pictures as guide to locate installation parts.
INSTALLATION INSTRUCTIONS
For the Washdown Rated Stainless Steel Pedestal Fan
1.Loosen the screw from the base assembly, insert the lower column to the base assembly. Align the hole of the lower column and base assembly, then tighten it.
2.Loosen the screws from the upper pose, insert the upper column to the lower column. Align the hole of the upper column
and lower column , then tighten it.
3.Align the motor flange and column.
4.Insert the pivot screw through the motor flange, column and washer. Attach using the position nut and tighten it. Insert the smaller position screw through the bottom radius. Attach it with the position nut.
5.Unscrew the nuts and washers from the motor .
6.Arrange the rear guard in its proper position.
7.Attach the rear guard by inserting and tightening the nuts to the motor (through the eyelets on the guard).
8.Insert the blade into the motor shaft until it reaches a stopping point and the set screw is in line with the flat groove on the motor shaft. NOTE: Make sure the blade’s set screw is facing the motor. You may need to loosen the set screw at the rear of the blade to slide it onto the shaft.
9.Firmly tighten the blade’s set screw with the spanner (not supplied).
CAUTION: Do not alter the angle of the blades.
10.Hang front grill on top rib of rear grill by utilizing the “U” shaped fixed clip at top of front grill rim.
User’s Manual
5
Washdown Rated Stainless Steel
Pedestal and Wall Mounted Fan
For the Washdown Rated Stainless Steel Wall Mounted Fan
1.Located a wall stud secure and solid enough to hold the weight of the base assembly. Carefully located and mark the center of wall stud. If you do not have a solid structural framing member at that location then you must provide an adequate alternative for mounting the fan.
2.Place mounting bracket against the wall centered with the centerline of the wall stud and 4 holes.
3.Drill 4 holes on the wall and secure bracket to wall using 4 lag screwsnot provided.
If mounting on a concrete wall, be sure to locate a structurally solid and secure location to hold the weight of the fan assembly and use suitable concrete anchors (not provided ) to mount the base to the wall.
4.Remove the 2 bolts, washers and nuts from the mounting bracket.
5.Align the holes on the mounting bracket with the holes in the motor flange on the motor assembly.
6.Insert the bolts and replace the washers and nuts removed in step 4.
7.Tighten the position bolt and nut. CAUTION: BE SURE TO SECURE THE KNOB.
8.Removed the 4 nuts, spring washers and flat washers from the bolts around the motor shaft.
9.Carefully slide the rear grille over the bolts.
10.Secure with the flat washers, spring washers and nuts removed in Step 8.
11.Carefully slide the blade assembly over the shaft and align the inner hex head driver provided with the slot on the shaft of the motor.
12.Tighten the blade assembly (16) with the hex head screw using the hex head driver provided with the fan.
NOTE: Keep the hex driver for future use. CAUTION: DO NOT ALTER THE ANGLE OF THE BLADES.
13.Hang front grille on top rib of rear grille by utilizing the hook.
14.Snap the front grille into the rear grille to secure.
62.8mm
113.6mm
User’s Manual
6
Washdown Rated Stainless Steel
Pedestal and Wall Mounted Fan
ELECTRICAL WIRING
Your licensed electrician is responsible for providing all electrical components and making all necessary connections from the motor to the appropriate power source.
All Washdown Rated Stainless Steel Fans come with a wiring schematic, usually printed on the nameplate of the motor. Fans must be wired exactly as shown. In the case of a dual voltage motor, take care to select the correct wiring configuration based on your voltage level. Warning: Improper wiring can damage motors, cause injury, and affect warranty coverage.
It is highly recommended that all fans have an independent disconnect switch located within visual sight of the fan. This switch should be used in conjunction with all “lock out, tag out” procedures during service and maintenance.
ELECTRICAL INSTALLATION
1. Remove the 4 screws from the Junction Box.Open the Junction Box Cover.
2. Unscrew the Thread-Lock Sealing Nut.
3. Thread the appropriate power cord through the Thread-Lock Sealing Nut and Cable Gland bodyin turn.
4. Follow the wiring diagram (Figure 2: 115V/60Hz, Figure 3: 230V/60Hz and table1:Plug and socket) for proper connections.
5. Tighten the Thread-Lock Sealing Nut. Thread-Lock Sealing Nut tightening requirements: No movement of the power cord under a maximum tension of 36 LBS.
6. Install the junction box cover: CAUTION:Make sure the sealing ring is in the original position after installation. Installation standard Requirements: Screws are tightened with a torque of 2.4NM.
Figure 2
Figure1 Strain Relief Bushing
A


Box Cover
Screw
A
MOTOR
TO MOTOR
Line
Thread-Lock Sealing Nut
GREEN
Cable Gland Body
GROUND TO
SWITCH BOX
115V/60Hz
Connected to Power Ground Wire (Green)
BROWN
WHITE
YELLOW
BLACK
ORANGE
RED
BLUE
Connected to Power Line Wire (Black)
Connected to Power Neatral Wire (White)
Connected together and insulated with the connector,
avoid the living parts touching the shell
ORANGE
WHITE
YELLOW
BLACK
RED
BLUE
BROWN
WHITE
GREEN
BLACK
115 VOLTS
LINE IN
plug
User’s Manual
7
Washdown Rated Stainless Steel
Pedestal and Wall Mounted Fan
Table1 Plug and socket
Wiring 115V, according to the user socket, you can choose 5-15P, 5-20P, 5-30P,5-50P. Wiring 230V, according to the user socket, you can choose 6-15P, 6-20P, 6-30P,-50P.
MAINTAINANCE AND CLEANING
Parts replacement and troubleshooting to be
performed only by qualified personnel.
Do not depend on any switch as the sole
means of disconnecting power when installing
or servicing the fan. Failure to do so may result
in fatal electrical shock.
1.To clean the fan, use a soft damp cloth. Wipe down with a dry cloth. Do not use cleaners that are harmful to paints or plastics.
CAUTION: Do not use gasoline, benzene, thinner, harsh cleaners, etc., which are dangerous and will damage the air circulator.
2 The propeller, guard, and motor should be cleaned periodically to prevent overheating, and/or operating in an imbalanced condition.
3. If cleaning requires the removal of a guard, remove only the front guard and re-install when finished in its originally installed position. Do not repair propeller if it becomes damaged. The propeller is accurately balanced at the factory and should be replaced if damaged.
4. Do not bend the blades.
5. Motor is permanently lubricated.
TROUBLESHOOTING
If your fan fails to operate, please follow these Instructions:
1. Make sure the fan is plugged in and the electrical outlet is working properly.
2. Check for any obstruction. If you find an obstruction, turn the fan “OFF”. Unplug the fan and carefully remove the obstruction.
3. Plug the fan in and turn it on again and see if it resumes normal.
NOTE: IF YOU EXPERIENCE A PROBLEM WITH YOUR FAN, PLEASE DO NOT ATTEMP TO OPEN OR REPAIR THE FAN YOURSELF. DOING SO COULD CAUSE DAMAGE OR
PERSONAL INJURY. Always consult the authorized dealer or certified electrician for further action.
CAUTION: There is no user maintenance part except regular cleaning as following description. All other servicing or mainte­nance should be performed by qualified service personnel.
Figure 3
230V/60Hz
Connected to Power Ground Wire (Green)
BROWN
YELLOW
BLACK
BLUE
ORANGE
RED
WHITE
Connected to Power Line Wire (Black)
Connected to Power Neatral Wire (White) Insulated with the connector, avoid the living parts touching the shell
Connected together and insulated with the connector, avoid the living parts touching the shell
TO MOTOR
BLUE
ORANGE
YELLOW
BLACK
RED
WHITE
BROWN
WHITE
GREEN
BLACK
GROUND TO SWITCH BOX
GREEN
230 VOLTS
LINE IN
plug
Loading...
+ 14 hidden pages