Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before installing and using this appliance. Please keep this Use and Care Manual properly for future reference.
2 / 18
Safety Instructions
1. Electrical Specifications
1. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding to the following instructions, please contact a qualified electrician.
2. The unit must be installed in accordance with national wiring regulations. Check available power supply and resolve any wiring problems before installation and operation of this unit.
3. For your safety and protection, this unit will be grounded through the power cord plug when plugging into a matching wall outlet. If you are not sure whether the wall outlet at your home are properly grounded, please consult an electrician. If supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid any hazards.
4. This appliance is not intended for people(including children)with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Young children should be supervised to ensure that they do not play with the appliance
2. WARNING:
To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow up these basic precautions:
Indoor use only, it is prohibited to use this unit outdoors or in humid environment such as bathroom etc. Do not remove ground prong. Do not use an adapter. Do not use an extension code. Never share the power outlet with other appliances. Never connect or disconnect the power plug with wet hands to avoid electric shocks. Never turn off the unit by unplugging. Unplug air conditioner before servicing. Never dismantle, repair or modify the unit without authorization to avoid body injury or property damage, be sure
it repaired by manufacturer or professionals.
Never put any objects into the unit. Never cover or obstruct air inlet or outlet to prevent overheating. Never hit or shake the unit to prevent damage. Never spray water or place the unit near water to prevent electric shocks. Never place the unit near gas appliances, fire or flammable liquids. Move and install the unit by two or more people. Keep children away from the unit. This appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or
3 / 18
instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision
3.Cautions:
Keep the unit at least 1 meter away from TV or radios to avoid electromagnetic interference. Do not expose the unit under direct sun light to avoid surface color fading. Do not tilt the unit for more than 35 degrees or upside-down while transporting. Place the unit on a flat surface and upright with less than 5 degrees inclination. The unit operates more efficiently in certain room locations (see Installation and Adjustment) Keep the drain hose in good condition without flexure then connect with unit. Manually adjust the vertical and horizontal louvers slightly to protect louvers from any damage. Empty the condensed drainage pan before putting the unit in storage to prolong the unit lifetime end of the
season.
Do not use chemical solvents (e.g. Benzene, alcohol-glazer) to clean the unit surface, do not scratch or damage
the unit.
Make sure to cut off the power before disassembling or installing the filter.
Remark: Do not use this unit in cooling mode if the ambient temperature is higher than 95
Function and Technical Specification
This new series of portable air-conditioners is designed with different cooling capacity levels. This unit offers cooling, dry, fan and sleep modes, ideal for home and office use.
4 / 18
This unit has two different fan-speed levels, accessible by panel control and remote control. Temperature setting range of this unit is 62-86℉(17-30℃) ※ This unit is designed with various protection functions such as 24-hour programmable timer, auto condensate
circle, super intelligent temperature sensor and water-full control and warning etc.
Technical Specification:
Model
Unit
NPA-10C
Power Supply
V~,Hz,Ph
110~120,60,1
Cooling Capacity
kW
2.93
Refrigerant/Charge
Oz
R410A/17.63
Rated input
Cooling W 1050
Rated Current
Cooling A 10.2
Moisture Removal
L/h
1.1
Air Circulation
m³/h
380
Noise
High
dB(A)
56
Low
dB(A)
52
Body Size
W×H×D
mm
300×761×360
Package Size
W×H×D
mm
355×882×460
Net Weight/Gross Weight
kg
24.5 /28.5
Application Area
13~18
Remark: The above cooling capacity is measured at standard working condition of ambient temperature dry-bulb 95, wet-bulb 75 (Indoor and outdoor, the same conditions)
Features and Identification of Parts
1. Features
New appearance and compact. Both horizontal and vertical louvers can be manually adjusted to enhance cooling performance. Integrated design of humanized handle and remote control compartment. Large LED control panel, more visualized. Power cord winding pillar and universal plug fixing holes to protect the power cord. High position of exhaust air outlet, easy assembly and exhaust venting quickly. 24-hour Timer function, unique on/off reminding music. 3-minute re-start delay protection to compressor and other multiple protection functions. Unique exhaust hose and fasteners, convenient installation.
2. Identification of Parts:
5 / 18
Screws for window kit assembly. 3 total
.
1. Control panel
2. Vertical louvers
3. Horizontal louvers
4. Air outlet frame
5. Front shell
6. Universal wheel
7. Back shell
8. Main vertical louver
9. Horizontal louvers connecting rod
10. Vertical louvers connecting rod
11. Handle (right side for remote control storage)
12. Protective net of exhaust vent
13. Universal plug fixing holes
14. Wire winding pillar
15. Back shell
16. Power cord
17. Drain hole and cover
18. Filter
19. Filters
20. Filter
21. Chassis
22. Remote controller
23. Exhaust hose assembly
24. Exhaust hose adapter
25. Window seal-plate assembly
26. 3 screws for window kit .
Installation & Adjustment
6 / 18
1. Installation Warning:
Keep this mobile air-conditioner in an upright position for at least 4 hours before first installation. Keep the unit in upright position at all times, even when moving to a new location. The air-conditioner should
be placed on a flat surface.
Do not install or operate this air-conditioner in a bathroom or other wet environments.
1.1 Installation of exhaust hose assembly and its adapter
1) Take out the exhaust hose assembly and its adapter from plastic bag.
2) Extend the exhaust hose at one end, screw the round end of adapter into exhaust hose in counter clockwise direction (as Photo)).
Note: Screw adapter into position, at least 3 full rotations, to insure a good connection of exhaust hose assembly and its adapter (as Photo).
1.2 Installation of the exhaust hose assembly into unit
1) Determine window seal-plate position, vertical or horizontal direction.
2) If window seal-plate will be in horizontal position, the slanted portion of the adapter should face right.
3) If window seal-plate will be in vertical position, the slanted portion of the adapter should be facing up.
1. Take the two ends of exhaust hose and its adapter assembly (in Photo below, figure A).
2. Put the hose end of the exhaust assembly without the adapter into exhaust vent on back panel (as in Photo).
Figure A.
Remarks:
Slant Panel A