GLI International 677F Operating Instructions Manual

OPERATING INSTRUCTION MANUAL
Model 677F
Remote-mount Analog
Flowmeter/Transmitter
Worldwide Sales:
GLI International, Inc.
phone: [414] 355-3601 fax: [414] 355-8346 e-mail: info@gli.com
In the interest of improving and updating its equipment, GLI reserves the right to alter specifications to equipment at any time.
Rev. 1-398 Model 677F Remote-mount Analog Flowmeter/Transmitter
European Sales:
GLI International Ltd
Eastman Way, Hemel Hempstead Hertfordshire. HP2 7HB England
phone: 01442 229310 fax: 01442 229311 e-mail: gli@gli.co.uk
A Member of the Environmental Instrumentation Group
1
HELPFUL IDENTIFIERS
In addition to information on installation and operation, this instruction manual may contain WARNINGS pertaining to user safety, CAUTIONS regarding possible instrument malfunction, and NOTES on important, useful operating guidelines.
A WARNING LOOKS LIKE THIS. ITS PURPOSE IS TO WARN YOU OF THE POTENTIAL FOR PERSONAL INJURY.
A CAUTION LOOKS LIKE THIS. ITS PURPOSE IS TO ALERT YOU TO POSSIBLE INSTRUMENT MALFUNCTION OR DAMAGE.
NOTE: A note looks like this. Its purpose is to alert you to im-
portant, useful operating information.
2
TABLE OF CONTENTS
PART ONE - INTRODUCTION
SECTION 1 GENERAL INFORMATION
1.1 Instrument Capability ...................................................5
1.2 Product Identification ................................................... 5
SECTION 2 SPECIFICATIONS................................................................6
PART TWO - INSTALLATION
SECTION 1 UNPACKING........................................................................7
SECTION 2 MECHANICAL REQUIREMENTS
2.1 Location........................................................................7
2.2 Mounting ...................................................................7-9
2.3 Conduit Hole Requirements.........................................9
SECTION 3 ELECTRICAL CONNECTIONS
3.1 Impeller Flow Sensor ................................................. 10
3.2 Power Supply............................................................. 10
3.3 Load Device (optional)...............................................10
3.4 Remote Reset Switch (only applies to 6-digit tot.) .....10
PART THREE - OPERATION
SECTION 1 OPERATING CONTROLS................................................. 12
SECTION 2 CALIBRATION...................................................................13
SECTION 3 RESETTING OPTIONAL 6-DIGIT TOTALIZER ................ 13
PART FOUR - SERVICE AND MAINTENANCE
SECTION 1 GENERAL INFORMATION
1.1 Keeping Sensor Clean............................................... 14
1.2 Avoiding Electrical Interference .................................14
SECTION 2 CUSTOMER ASSISTANCE..........................................14-15
PART FIVE - SPARE PARTS AND ACCESSORIES
Rev. 1-398 Model 677F Remote-mount Analog Flowmeter/Transmitter
......................................................................................16-17
3
TABLE OF CONTENTS (continued)
ILLUSTRATIONS
Figure 2-1 Mounting Arrangements ...........................................................................8
Figure 2-2 Installation Dimension Details ..................................................................9
Figure 2-3 Electrical Hookup Diagram.....................................................................11
4
PART ONE - INTRODUCTION SECTION 1 - GENERAL INFORMATION
PART ONE - INTRODUCTION
SECTION 1
GENERAL INFORMATION
1.1 Instrument Capability
1.2 Product Identification
The Model 677F remote-mount analog flowmeter/transmitter can be used with any GLI impeller flow sensor. With stan­dard brackets, the Model 677F can be panel, surface, or horizontal pipe mounted. When ordered with special, op­tional mounting brackets, the Model 677F can be vertical pipe mounted.
The Model 677F provides flow rate measurements, and may be equipped with a 6-digit resetting totalizer or a 7-digit non-resetting totalizer. In this case, the Model 677F also provides a reading of total volumetric flow.
The Model 677F transmits a 4-20 mA signal, corresponding to the measured flow rate, on a simple two-wire hookup. Any of the following (or similar type) devices can be con­nected to the Model 677F:
Data logger
Recorder
Remote readout
The instrument serial number is located on the backside of
the display board. Refer to this serial number for convenient identification should technical assistance be required.
Rev. 1-398 Model 677F Remote-mount Analog Flowmeter/Transmitter
5
PART ONE - INTRODUCTION SECTION 2 - SPECIFICATIONS
SECTION 2
SPECIFICATIONS
2.1 Operational
Display:
Flow Rate............................. 5-1/2 inch (140 mm) dual-scaled meter with
250° meter movement
Total Flow (optional)............. 7-digit non-resetting totalizer or 6-digit reset-
ting totalizer, each with 0.15 inch (4 mm) high digits
Measuring Range....................... From 0-5 to 0-80,000 GPM (0-18 to
0-300,000 LPM) with ±2% of full scale accuracy
2.2 Performance
(Electrical, 4-20 mA Output)
2.3 Mechanical
Ambient Conditions .................... 14 to 122°F (-10 to +50°C); 0-90% relative
humidity
Sensor-to-Transmitter
Distance ............................... 2000 ft. (609 m) maximum
Output Transmission Distance ... Limited only by wire resistance and power
supply voltage
Power Requirements.................. 18-36 VDC, 6 watts maximum
Stability...................................... 0.06% of span per 24 hours, non-cumulative
Repeatability.............................. 0.05% of span
Non-linearity ..............................0.06% of span
Temperature Drift ....................... Zero: 0.01% of span per °C;
Span: 0.02% of span per °C
Response Time.......................... Selectable, 2 or 10 seconds (approximately)
to 90% of value upon step change
Load Driving Capacity................ Maximum load (in ohms) is dependent on
power supply voltage. Use the following equation to calculate the maximum allowable load:
Load (ohms) = (Power Supply VDC - 5) x 50
Enclosure (optional)................... NEMA 4X; ½ DIN, polycarbonate; surface
mount
Net Weight................................. 1 lb. (0.46 kg) approximately
6
Loading...