GLG Pastello Minibeam MKII User Manual

GLG LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
1
USER
M
ANUA
L
Pastello Minibeam MKII
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
2
CON
TE
NTS
1. General information 2
2.
Safety
instructions 3
3. Trait
and skill specifications 4
4. Operation
panel 6
5.
Dimensional
drawings 6
6. Photometric
data 7
7.
Mounting and
Installation 7
8. Power supply and Signal connection 9
9.
Display menu
11
10.
DMX
traits
18
11. Circuit
connecting
diagram
22
12. Trouble
dispose
23
13.
Cleaning and
Maintenance
24
14.
Duty exonerat
ive and
Copyright protection
24
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
3
1
. GENERAL
IN
FOR
MAT
IO
N
INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable LED fixtures on the market today. Our company has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
Notice: As part of our ongoing commitment to continuous products
update, company will keep the right to improve this products, the information in this menu may be changed in the future, the company reserve the right to change the data without any advises.
UNPACKING: Thank you for purchasing our company products. Every product has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for damage and be sure all accessories necessary to operate the fixture have arrived intact. In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Inside the box you should find: the fixture, a DMX XLR cable, a power cable, and this user manual.
Please do not discard the shipping carton in the trash. Please recycle whenever possible.
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
4
2
. SAFETY
INSTRUCT
IO
NS
Notice:
To guarantee proper and consistent operation, it is important to follow the guidelines in this manual. Our company will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual.
1. In order to ensure the light could operate normally, the ambient temperature couldn't be higher than 38and no lower than- 2.
2. Under normal condition, the highest sectional surface temperature
may be up to 60 .
3.These projectors are designed depends on the electric shock
protection, the projector should be connected with the power supply system which connected ground enough. The projector's ground cable should be connected with the ground cable of the power supply system as well. The ground mark of the light metal cover should be connecting with the installation bricked steadily.
4. Don't use the power cable when the insulation is damaged.
It must be the manufacturer or distributor or the professional person to change the damaged power cable in order to avoid any dangerous.
5.Please check the voltage, frequency data of power supply system is
suitable for the mentioned on the projector. Please do avoid the different voltage between them and burn the projector.
6.Do not attempt to operate this fixture if the power cord has become
damaged or frayed.
7.Never open this fixture while in use.
8.Never look directly into the light source. You risk injury to your
retina, which may induce blindness.
9.Please be aware that damages caused by modifications to the device
are not subject to warranty.
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
5
3. PERFORMANCE
TRAIT AND SKILL S
PECIFICATIO
NS
Voltage:AC100~240V 50/60Hz.Power118W.
LED chip:10W,RGBW 4 in 1 LED chip.
LED QTY7PCS.
LED life:50000H.
Lens degree:standard 8°.
Beam angle:12°.
Color: RGBW macro color system.
Strobe:1-30 times/ second electronic strobe and random strobe.
Dimmer :65536 class dimmer.
Pan/Tilt : Pan :540° times /1.5 seconds Tilt:180°/0.5 seconds.
Control Mode: DMX512, RDM, Stand-alone mode ,Voice Control
mode , Mater-Slave mode , Wireless DMX512.
Channel: Standard Channel : 9 , Extend Channel : 15.Display Menu:
1. 2.4 inches TFT touch screen, Chinese and English two version language. 2, Display board can record device’s using time , show device’s temperature, channel data and software version . 3, Edit the procedure
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
6
Other feature :
1.Extend IP address function , each IP address maximum can set 64 ID
2.Support DMX signal priority identification, when lose the signal
it would be turn into Black , default scene , Automatic function
etc according to your set.
3.Remote control function: control the procedure, speed etc function
by the remote controller when the product under the condition
without signal.
4.software upgrade : upgrade software by XRL cable.
Outlooking: adopt ABS anti-fire plastic.
Carton size : 270×260×350MM. N.W.: 3.8KG G.W.: 5.7KG
Light size:226×268MM
GLG LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
7
4. OPERATION
P
AN
EL
5. DIMENSIONAL D
RAWIN
GS
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
8
6. PHOTOMETRIC DATA
7
. MOUNTING AND INSTA
LLATION
Cautions:
For added protection mount the fixtures in areas outside walking paths, seating areas, and away from areas were unauthorized personnel might reach the fixture. Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device's weight. Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable. To avoid injury, never stand directly below the device when mounting, removing, or servicing the fixture. Mounting points:
Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet.
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
9
Mountin
g
Our company is fully operational in any mounting position, hanging upside-down, side mounted, or set on a flat level surface, etc. Be sure this fixture is kept at least 0.5m (about 1.6feet) away from any flammable materials (decoration etc.).
When clamp mounting; always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure. See the image below.
GLG LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
10
8
. POWER SUPPLY AND SIGNAL
CONN
ECTIO
N
1. Power s
upp
ly
Use the professional plug to connect the projector and main power supply. Please pay attention to the voltage, frequency the same as the mentioned on the projector. Suggest each light has separately switched of the power supply so that could turn on or turn o each projector desultorily.
2. Signal c
onnection
Please use the round 3/5-pin XLR plugs &sockets oered
by menu facture to connect the rst projector's output to the second projector' input and connect the second projector's output to the third device's input. And in the same way for the rest, eventually connect the last device's output, all the devices are together as the following gure.
The devices’ control signal output or input by using the 3/5-pin XLR pug and socket. If need to long then the communication cable, p
lease make sure the both side of 3/5-pin plug is one to one. (one to one, two to two, three to three). Otherwise, the communication cable will be interrupted.
The communicate cable is 2-pin shielded cable 75 Resistance with each core is at least a 0.5mm diameter. (Caution: All the inside leading wire of 3/5-pin XLR plug couldn't touch each other or plinth). Recommend to use the DMX signal terminator for the installation to avoid the electronic noise damage the digital control signal. Simply
GLG LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
11
speaking, DMX terminator is an XLR connector with a 120 1/2w resistor connected across pin 2 and 3.Which is then plugged into the output socket on the last projector in the chain. Refer to the connection as above:(Picture ).We suggest using the DMX signal distributor when the distance of the lights over 15meter,In case of eect the light communication because of the signal feeble.
3. Light power connection:
After doing the above operation and making sure all the devices had been installed with natural operate, press the power switch to check whether everything is working normally.
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
12
9
. DISPLAY
M
EN
U
Menu
Menu
Menu
R
emark
SETTING
DMX Ad
dress
001-512
Fixture ID
000-064
Channel mode
S
tandard(9CH
) D
efault
E
xtended(
15CH
DMX
input
mode
Wired
input
D
efault
Wireless
input
Reset wireless
DMX
function
Hold Black D.scene
Program
1
Program
2
Program
3
Program
4
Program
5
Program
6
Program
7
Program
8
Slave-Master
Slave
mode
Master mode
Music
control
Close
Open
Exit
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
12
Menu
Menu
Menu
R
emark
INFO
Fixture times
Power
on time
****H
Lamp
on time
****H
Fixture
t
emperatures
LAMP_TEM
***℃
RDM
UID
3888:********
DMX live
1.
Dimmer 0-
255
2.
Dimmer
fine 0-
255
3. Shutter 0-
255
4.
Red 0-
255
5. Green 0-
255
6. Blue 0-
255
7. White 0-
255
8.
Macro
colour 0-
255
9. Pan 0-
255
10. Pan fine 0-
255
11. Tilt 0-
255
12. Tilt fine 0-
255
13. Fixture control 0-
255
14. Calibration 0-
255
15. Slave ID 0-
255
Version info
LED_XY_SOFT:V*.** LED_DPY_SO F T:V*.**
Exit
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
13
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
14
Menu
Menu
Menu
Menu
Remark
PERSON
Pan/Tilt
PT swap
OFF Default ON
Pan invert
OFF Default ON
Tilt invert
OFF Default ON
Exit
DMX reset
ON
Default
OFF
Reset
System reset
Exit
Quick
closedown
Open
Close
P/T angle limit
Close
Open
Program on/off
Close
Open
Set p/t angle
Pan start
Pan end
Tilt start
Tilt end
Exit
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
15
Menu
Menu
Menu
Menu
R
emark
PERSON
Display
Display
language
English(英文
) D
efault
C
hinese(中文
)
Display sleep
Light always
2 minutes
D
efault
4 minutes
6 minutes
Display
intensity
10-100
D
efault
:50
Display
rotation
Normal
D
efault
Rotate 180
TFT calibration
Exit
Exit
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
16
Menu
Menu
Menu
R
emark
MANUAL
1.
Dimmer
0-255
2.
Dimmer fin
0-255
3.
Shutter
0-255
4.
Red
0-255
5.
Green
0-255
6.
Blue
0-255
7.
White
0-255
8.
Macro colo
0-255
9.
Pan
0-255
10.
Pan fine
0-255
11.
Tilt
0-255
12.
Tilt fine
0-255
13.
Fixture c
0-255
14.
Calibrati
0-255
15.
Slave ID 0-255
Exit
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
17
Menu
Menu
Menu
Menu
PROGRAM
Edit
program
Edit
program
1
Scene 0-
100
1.
Dimmer
0-255
2.
Dimmer fin
0-255
3.
Shutter
0-255
4.
Red
0-255
5.
Green
0-255
6.
Blue
0-255
7.
White
0-255
8.
Macro colo
0-255
9.
Pan
0-255
10.
Pan fine
0-255
11.
Tilt
0-255
12.
Tilt fine
0-255
13.
Fixture c
0-255
14.
Calibrati
0-255
15.
Slave ID 0-255
Save scene
Exit
Edit
program
2
Same as Edit program1
Edit
program
3
Same as Edit program1
Edit
program
4
Same as Edit program1
Edit
program
5
Same as Edit program1
Edit
program
6
Same as Edit program1
Edit
program
7
Same as Edit program1
Edit
program
8
Same as Edit program1
Exit
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
18
Menu
Menu
Menu
Menu
PROGRAM
Set program
Set program 1
Start step 0-100 End step 0-100 Step time 0-255 Save Exit
Set program 2 Same as Set program 1
Set program 3 Same as Set program 1
Set program 4 Same as Set program 1
Set program 5 Same as Set program 1
Set program 6 Same as Set program 1
Set program 7 Same as Set program 1
Set program 8 Same as Set program 1
Exit
Run Running program…
Fixed scene
Scene
001-100
Exit
SERVICE
Error list
Adjust
Pan
±5.00%
Tilt
±5.00%
Exit
Factory
Factory default **** Adjust default **** Time clean **** Developer **** Machine sel. **** Exit
Updata
****
Exit
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
19
10
DMX TRAIT
S
Channel
DMX
values
%
Effect
1.
Dimmer
0-255 0-100
2.
Dimmer fine
0-255 0-100
3.
Shutter
0-9 0-3 Unused range
10-49 4-19
Lightdarkslowfast
50-89 20-34
Darklightslowfast
90-119 35-46
Darklightdarkslow→fast
120-179 47-70 Random fastslow strobe
180-249 71-98 In-phase, slowfast
250-255 99-100 Unused range
4. Red 0-255 0-100
5. Green 0-255 0-100
6. Blue 0-255 0-100
7. White 0-255 0-100
8.
Macro colour
0-1 0-1 Unused range
2-254 1-99 Shadow
255 100 Unused range
9.
Pan
0-255 0-100
10.
Pan fine
0-255 0-100
11.
Tilt
0-255 0-100
12.
Tilt fine
0-255 0-100
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
20
Channel
DMX
values
%
Effect
13.
Fixture
control
0-9 0-3 Unused range
10-14 4-5 Complete reset
15-19 5-7 Open
20-24 7-9 Close
25-29 10-11 Quick open
30-34 12-13 Quick close
35-239 14-93 Unused range
240-244 94-95
Pan
245-249 96-97
Tilt
250-255 98-100 Unused range
14.
Calibration
0-255 0-100
15.
Slave ID
0-2
0
All IDs are efficient lighting its own
ID to 0, the channel set to any value
is valid
3-5 1-2 ID:1 effective
6-8 2-3 ID:2 effective
... ...
192-194 75-76 ID:64 effective
195-197
76-77
ID is(2*n)+1 effective,(n=0-31)
13579…63
198-200
77-78
ID is(2*n)+2 effective,(n=0-31)
246810…64
201-203
78-79
ID is(3*n)+1 effective,(n=0-21)
1471013…64
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
21
Channel
DMX
values
%
Effect
15.
Slave ID
204-206
80-81
ID is(3*n)+2 effective,(n=0-20)
258111462
207-209
81-82
ID is(3*n)+3 effective,(n=0-20)
369121563
210-212
82-83
ID is(4*n)+1 effective,(n=0-15)
159131761
213-215
83-84
ID is(4*n)+2 effective,(n=0-15)
2610141862
216-218
84-85
ID is(4*n)+3 effective,(n=0-15)
3711151963
219-221
85-86
ID is(4*n)+4 effective,(n=0-15)
4812162064
222-224
87-88
ID is(5*n)+1 effective,(n=0-12)
1611162161
225-227
88-89
ID is(5*n)+2 effective,(n=0-12)
2712172262
228-230
89-90
ID is(5*n)+3 effective,(n=0-12)
3813182363
231-233
90-91
ID is(5*n)+4 effective,(n=0-12)
4914192464
234-236
91-92
ID is(5*n)+5 effective,(n=0-11)
51015202560
237-239
93-94
ID is(6*n)+1 effective,(n=0-10)
1713192561
GLG
LIGHTING EQUIPMENT
www.goedlichtengeluid.nl
info@goedlichtengeluid.nl
22
Channel
DMX
values
%
Effect
15.
Slave ID
240-242
94-95
ID is(6*n)+2 effective,(n=0-10)
2814202662
243-245
95-96
ID is(6*n)+3 effective,(n=0-10)
3915212763
246-248
96-97
ID is(6*n)+4 effective,(n=0-10)
41016222864
249-251
97-98
ID is(6*n)+5 effective,(n=0-9)
51117232959
252-254
98-99
ID is(6*n)+6 effective,(n=0-9)
61218243060
255
100
All IDs are valid
Standard(9CH)
1.Dimmer 4.Green 7.Pan
2.Shutter 5.Blue 8.Tilt
3.Red 6.White 9.Fixture control
Extended(15
CH
1.Dimmer 6. Blue 11.Tilt
2.
Dimmer fine
7.White 12.Tilt fine
3.Shutter
8.Macro colour
13.Fixture control
4.Red 9. Pan 14.Calibration
5.Green 10.Pan fine 15.Slave ID
GLG
LIGHTING EQUIPMENT
www.goedlichtengluid.nl
info@goedlichtengeluid.nl
22
11.
CIRCUIT CONNECTING DIA
GRAM
GLG
LIGHTING EQUIPMENT
www.goedlichtengluid.nl
info@goedlichtengeluid.nl
23
12
. TROUBLE DISPO
SE
It is recommended some solution for some normal trouble shooting. Any inextricability problems should always be handling by the professional person. Disconnect the power supply before maintenance the light.
LED off
1. Please check if install the suitable voltage
2. Please check whether the led will reach the end of their life can explode; please replace a same description led.
3. Please check if the power supply is enough.
4. Please check whether the DMX 512 controller pass the "turn on" order.
Though the light is lighting, but it couldn't accept the control order:
1. Please check the start code address and the function option are
correct.
2. Please check whether the communicate control cable is on good connection or the cable is too long or interrupt.
3. Please check the control system is not valid, check the signal amplifier of chain connected is valid.
4. Please check whether the communicate cable is too long or the other equipment is mutually conjugate.
5. Please arrange the wire well, shorter the signal cable, put the high voltage cable and low voltage cable separately.
6. Add the signal amplify isolator.
7. Signal cable is used the excellent screening doublet (Resistance 75 OHM
8. The end of the light end and the end resistance.
The light can't move:
1. Please check if the power supply is suitable for the light voltage
data.
2. Please check the fuse of input voltage is defective.
3. Please check the light if they are deformation, inside parts is broken, become wet etc will lead the loose contact.
GLG
LIGHTING EQUIPMENT
www.goedlichtengluid.nl
info@goedlichtengeluid.nl
24
13
. CLEANING AND MAIN
TE
NANCE
1. In order to ensure the projector could work normally. It should be
kept clean always .The lens should also be regularly cleaned to maintain an optimum light output. Do not use any type of solvent on lens. It will damage the projector.
2. Suggestion: The continue usage of the light don't exceed 4 hours. Or
it will shorter the usage of the lamp. Please use the alternative operation to solve this problem.
3. Please disconnect the power supply when begin to maintenance take
down the light. Please let the parts cool down 10 minute at least then begin to install.
4. Please inspect the lens or other moving parts timing and keep them
clear and static. If find anything damaged or looseness must change a lamp or fix the lamp in order to avoid the accident.
14.DUTY EXONERATIVE
AND
COPYRIGHT PRO
TECT
ION
Any products broken that didn't according to the instruction is not guarantee to keep it in good repair.
The commentary for all the instruction belongs to the supplier in final.
No authorize can't copy.