If a permanent connection is used, the appliance's power supply line must be fitted with an omni polar breaking
device with contact gap of at least 3 mm, located in an easily accessible position close to the appliance itself.
If a socket and plug connection is used, check that they are of the same type. Do not use reducers, adapters or
junctions since they may cause overheating or burns.
Operation at 220-240 V~: use a type H05RR-F three-wire cable
(Cable of 3 x 1.5 mm²).
The earth wire (yellow-green) must be at least 20 mm longer than
the other wires at the end for connection to the appliance.
The manufacturer declines all responsibility for injury or damage caused by failure to comply with the
above regulations or deriving from tampering with even just one part of the appliance.
4.2 Positioning the oven
Only a qualified person in compliance with the instructions provided install the appliance. The
manufacturer declines all responsibility for improper installation, which may harm persons and animals and
damage property.
Important: - The power supply to the appliance must be cut off before any adjustments or maintenance work
is done on it;
- Air duct is supposed to use in Ventilation;
- cabinets with a veneer exterior must be assembled with glues which can withstand
temperatures of up to 100℃.
Installation of Built-in Ovens
In order to ensure that the built-in appliance functions properly, the cabinet containing it must be appropriate.
The appliance is designed for built-in installation (class 3) in cabinets of any heat-resistant material. Comply
with the dimensions shown in figures 1, 2and3. when installing under worktops, comply with the
dimensions shown in figure 1-3. when installing under worktops incorporating hobs, a gap of at least 110 mm
must be left from any side wall, as shown in figure 1 . when installing in tall units , comply with the dimensions
shown in figure 1-2 , bearing in mind that the top/rear of the unit must have an opening 45mm deep. Screw the
4 screws A into the inside of the frame (fig.1) .For installation under tops, make sure that the rear/bottom of the
unit has an opening similar to that shown in figure 1 (B),and that the front/bottom of the unit has an opening an
aperture of at least 45×560mm similar to that shown in figure 1-3 (C) ,or the aperture similar to window shade,
make sure that aperture area of at least 45×560mm. see the instructions supplied with the hob for the relative
positioning and fixing procedures.
In compliance with current safety standards, contact with the electrical parts of the oven must not be possible
once it has been installed.
All parts, which ensure the safe operation of the appliance, must be removable only with the aid of a tool.