TECHNICAL SPECIFICATIONS
T
OUGHENED
GLASS
COOKTOP
Total Gas
Model
CT 1021 GT FB HF CT 1033 GT XL FB DD CT 1033 GT XL FB DD BL CT 1038 GT FB CT 1038 GT FB M CT 1038 SQ GT FB CT 1038 SQ BL FB CT 1038 GT FB M BL CT 1042 GT FB CT 1042 GT FB M CT 1042 GT FB M BL CT 1048 GT FB CT 1048 GT FB M CT 1048 SQ GT FB CT 1048 SQ BL FB CT 1048 GT FB M BL CT 1049 GT FB CT 1049 SQ GT FB
Rating
g/h kcal/h
364 541 541 541 541 541 541 541 684 684 684 684 684 684 684 684 684 684
FREE STANDING HOB
Total Gas
Model
BH 1073 FS FB BW BH 1074 FS FB BW
Rating
g/h kcal/h
541 684
For Use with Comme rcial L .P.G. at 2.942 k N/mm² (30gf /cm²)
Small
Burner
g/h kcal/h
3966
143
1554
1 x
5896
143
1554
1 x
5896
143
1554
1 x
5896
143
1554
1 x
5896
143
1554
1 x
5896
143
1554
1 x
5896
143
1554
1 x
5896
143
1554
1 x
7450
143
1554
2 x
7450
143
1554
2 x
7450
143
1554
2 x
7450
143
1554
2 x
7450
143
1554
2 x
7450
143
1554
2 x
7450
143
1554
2 x
7450
143
1554
2 x
7450
143
1554
2 x
7450
143
1554
2 x
Small
Burner
g/h kcal/h g/h kcal/h g/h kcal/h
5896
143
1554
1 x
7450
143
1554
2 x
DEALER’S STAMP & SIGNATURE
A. BURNER RATINGS
Big
Burner
g/h kcal/h g/h kcal/h
-
-
­1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
177
1930
1 x
A. BURNER RATINGS
Big
Burner
177
1930
1 x 1 x
1 x
177
1930
1 x
High Flame
Burner
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
2412
221
High Flame
Burner
2412
221
2412
221
B. OVERALL DIMENSION (mm)
Width
660 726 726 780 780 780 780 780 600 600 600 700 700 700 700 700 950 900
Depth
400 445 445 460 460 460 460 460 565 565 565 565 565 565 565 565 445 465
Height
118 118 118 118 118 140 140 118 118 118 118 118 118 140 140 118 118 140
Approx.
Wt. (Kg.)
10.20
10.20
11.40
11.40
11.20
11.20
11.40
10.50
10.50
10.50
12.00
12.00
12.90
12.90
12.90
12.00
13.20
B. OVERALL DIMENSION (mm)
Width
730 770
Depth
450 540
Height
130 130
Approx.
Wt. (Kg.)
11.40
12.90
Subje ct to change without pr ior notice
8.50
U S E R ’ S G U I D E
SERAIL NO. MODEL NO.
DATE OF PURCHASE
NAME & ADDRESS OF OWNER
Manufactured by
Plot No. 919, Sec-68, IMT, Faridabad, Haryana.-121004.
I-34, DLF Indl. Area, Phase 1, Faridabad (Haryana), INDIA.
E-mail : cr@glenindia.com Website : www.glenindia.com
Glen Appliances Pvt. Ltd.
Customer Care & H.O.
Phone : 0129-2254191
TOUGHENED
GLASS
(ONLY IN GT MODELS)
STURDY PAN
SUPPORT
IS : 4246
CM/L - No. - 9512382523
INSTALLATION
The gas cylinder should be placed vertically and should not tilt. The Product should be placed at a convenient working height against a wall. It should be
kept away from shelves and curtains Windows should be closed and the use of fans should be avoided during its operation. The flexible tube connecting the cylinder to the Product should be gas resistant and of an
approved brand. It should not be longer than a meter and should be kept away from any source of heat. The tube should not be subjected to external pressure, twisted or sharply looped
When the Product is not in operation ensure that the regulating knobs on the Product are in the ‘OFF’ position and the regulating valve on the cylinder is ‘CLOSED’
Push the rubber hose onto the inlet nozzle as far as it will go.
INSTRUCTIONS FOR USE
To light the Product, open the regulating valve, light a match stick and hold it close to the burner port. Now press the corresponding regulating knob and turn it anticlockwise to the ‘ON’ position.
To turn off the flame, turn the regulating knob to the ‘OFF’ position. During cooking, ensure that the ingredients being cooked do not overflow, which may
extinguish the flame or choke the burner ports. In case of leakage of gas or any other defect, report to your gas dealer and get the Product
checked/rectified by an authorised person only. Use a damp cloth to clean your Product. Make sure that there are no inflammables near the Product. When the Product is in use check from time to time that it burns normally.
While using a lighter to ignite the burner, keep a distance of atleast 0.5 cm between them to prevent gas from burning in the Gas pipe. In case this happens, immediately switch off the burner and re-ignite
Toughened glass is used for the cooking table in GT models. However necessary precautions in handling of glass is very important. make sure that when the glass is hot, there should not be any dripping of cold water or liquid on glass as it may damage the glass.
Glass may break if gas tandoor is used. The breakage of glass due to any reason is not covered under guarantee.
GUARANTEE
This GLEN Product is fully guaranteed against any defect arising out of defective materials or faulty workmanship for a period of two years from the date of purchase. Should any defect develop in this Product during the guarantee period, Glen Appliances Pvt. Ltd. Undertakes to get the Product or any parts thereof repaired free of charge.
GUARANTEE IS NOT VALID IF
The Product is not used according to the direction given in the instruction manual. Defects are caused by improper or reckless use. The repair work is carried out by persons not authorised by the company. The serial no. has been deleted, defaced or altered. The breakage of glass due to any reason whatsoever is not covered under guarantee. The Bill/cash memo is not presented . Any modification or alteration of any nature is made in the Product. The manufacturer is not responsible for any consequential losses arising out of misuse of
the appliance or due to non-observance of necessary precautions in using L.P. Gas/Electric power.
TERMS & CONDITIONS FOR 5 YEAR WARRANTY
Customer has to register online for availing this 5 year warranty on the Glen India Website or Mobile App (in process).
The registration should be done within 90 days of date of purchase. The product has been used as per the instruction mentioned in the instruction manual. The product has been used for domestic purpose only, in case used for commercial
purpose the warranty is not valid. The product has not been put to misuse and serviced at regular intervals at least once in a
year by the authorised service centre. The warranty is valid on the Forged Brass Burner only and not on the mixing tube. In case of Toughened Glass the maximum number of free replacements will be limited to
2 times with in the 5 years period . In case the glass breaks while using Pathri Tawa or Gas Tandoor for making Bati then the
warranty is not valid. In case of any requirement of change of above parts only the parts will be replaced free of
charge the labour cost and service/visit charges will have to be paid by the customer. Customer will have to produce this warranty card and the cash memo to avail the
warranty. In case the Gas Valve is changed from LPG to PNG not by the company authorised
service centre then the warranty will not be valid. In case of any problem customer can get in touch with us at :-
Toll Free 92666-55555, E-mail : cr@glenindia.com and we will be willing to help.
Loading...