![](/html/36/36dc/36dc46c87dc896345b846fcf562855615f5be591df3561c674f977bb2892b68c/bg1.png)
Thanks for
choosing
our goods please read this
manual carefully
before your
operating
![](/html/36/36dc/36dc46c87dc896345b846fcf562855615f5be591df3561c674f977bb2892b68c/bg2.png)
Introduction .........................................................3
Dimensions...........................................................4
Safety Information ...............................................5
Using for the first time .........................................7
AC power..............................................................8
Data link................................................................9
Setup&
Menu chart
...............................................10
Operation and effects...........................................13
DMX Protocol......................................................15
Channel Function.................................................22
Service and maintenance......................................25
![](/html/36/36dc/36dc46c87dc896345b846fcf562855615f5be591df3561c674f977bb2892b68c/bg3.png)
Introduction
This kind of wash use 19*15W Osram 4in1 RGBW leds with low energy consumption
super brightness and long life time,it allow you to create an endless range of variations
color and super effects.
19pcs 15W multi color LEDs individually controllable offer more options for the
designers and also with eye candy looks LEDs offer single lens with fully pre mixed
color. Beam angle zooming 11-58 degrees provide both Beam and Wash effects.
Features
Color mixing: multi RGBW 4 in 1 LED,individually controllable with eye candy looks
LED board,RGB color mixing.
Beam color temperature control: CTO variable 10 000 - 2500 K
5 DMX Channels mode: 14CH 17CH 28CH 74CH 93CH 85CH
Color LCD display,New design operation buttons
Input : 100V~240V,50Hz~60Hz
DMX input port:3pin;5pin XLR
Pan / tilt:540°/ 270°16bit
Fan cooling
Color macro effects
Linear smooth dimming 0-100%
![](/html/36/36dc/36dc46c87dc896345b846fcf562855615f5be591df3561c674f977bb2892b68c/bg4.png)
Dimensions
AII dimensions are in millimeters
![](/html/36/36dc/36dc46c87dc896345b846fcf562855615f5be591df3561c674f977bb2892b68c/bg5.png)
Safety Information
The following symbols are used to identify important safety information on the product and in this manual
Risk Group 3 (high risk) LED product according to EN 62471. Do not view the light
Output with optical instruments or any devices that may concentrate the beam.
This product is for professional use only.It is not for household use.
This product exist risks of severe injury or dead due to fire and burn hazard.!
electric shock and falls.
Read this manual before installing powering or servicing the fixture.
follow the safety precautions below and observe all warnings in this manual and printed on
the fixture.Contact the dealer if needed.
![](/html/36/36dc/36dc46c87dc896345b846fcf562855615f5be591df3561c674f977bb2892b68c/bg6.png)
PROTECTION FROM ELECTRIC SHOCK
• Disconnect the fixture from AC power before removing or installing any
cover or part and when not in use.
• Always ground (earth) the fixture electrically.
• Use only a source of AC power that complies with local building and
electrical codes and has both overload and ground-fault (earth-fault) protection.
• Before using the fixture check that all power distribution equipment and
cables are in perfect condition and rated for the current requirements of all
connected devices.
• Power input and throughput cables must be rated 20 A minimum,have three
conductors 1.5 mm2 (16 AWG) minimum conductor size and an outer cable
diameter of 5 - 15 mm (0.2 - 0.6 in.). Cables must be hard usage type (SJT or
equivalent) and heat-resistant to 90°C (194° F) minimum. In the EU the cable
must be HAR approved or equivalent.
• Use only Neutrik Powercon NAC3FCA cable connectors to connect to power
input sockets. Use only Neutrik Powercon NAC3FCB cable connectors to
connect to power throughput sockets.
• Isolate the fixture from power immediately if the power plug or any seal cover
cable or other component is damaged defective deformed wet or showing signs
of overheating. Do not reapply power until repairs have been completed.
• Do not expose the fixture to rain or moisture.
PROTECTION FROM BURNS AND FIRE
• Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C
(104° F).
• The exterior of the fixture becomes hot during use. Avoid contact by persons
and materials. Allow the fixture to cool for at least 10 minutes before handling.
• Keep all combustible materials (e.g. Fabric,wood,paper) at least 100 mm
(3.9 in.) away,from the fixture.
• Keep flammable materials well away from the fixture.
• Ensure that there is free and unobstructed airflow around the fixture.
• Do not expose the front glass to sunlight or other strong light sources from any
angle.
![](/html/36/36dc/36dc46c87dc896345b846fcf562855615f5be591df3561c674f977bb2892b68c/bg7.png)
• Do not illuminate surfaces within 200 mm (7.9 ins.) of the Gaea.
• Do not attempt to bypass thermostatic switches or fuses.
• Do not stick filters masks or other materials onto any optical component.
• Do not modify the fixture in any way not described in this manual
• Do not look at LEDs with magnifiers telescopes binoculars or similar optical
instruments that may concentrate the light output.
• Fasten the fixture securely to a fixed surface or structure when in use. The
fixture is not portable when installed.
• Ensure that any supporting structure and/or hardware used can hold at least
10 times the weight of all the devices they support.
• Allow enough clearance around the head to ensure that it cannot collide with
an object or another fixture when it moves.
• Check that all external covers and rigging hardware are securely fastened.
• Block access below the work area and work from a stable platform whenever
installing servicing or moving the fixture.
• Do not operate the fixture with missing or damaged covers shields or any
Important! Open the package make sure everything is in good conditions
before using if damage happened please don't connect power ,contact the
supplier as soon as possible !
Please read carefully before
using"Safety I
nformation"
• Check that the local AC mains Dower source is within the fixture's Dower
![](/html/36/36dc/36dc46c87dc896345b846fcf562855615f5be591df3561c674f977bb2892b68c/bg8.png)
Warning! Read "Safety Information" starting on page 5 before connecting
the Gaea to AC mains power.
Warning! For protection from electric shock,the Gaea must be grounded
(earthed).The power distribution circuit must be equipped with a fuse or circuit
breaker and ground-fault (earth-fault) protection.
Warning! Socket outlets or external power switches used to supply the Gaea
with power must be located near the fixture and easily accessible so that the
fixtures can easily be disconnected from power.
Important!Do not insert or remove live Neutrik Powercon connectors to
apply or cut power ,as this may cause arcing at the terminals and damage the
connectors.
Important! Do not use an external dimming system to supply power to the
Gaea as this may cause damage to the fixture that is not covered by the product
warranty.
Power voltage
Warning! Check that the voltage range specified on the fixture's serial number
label matches the local AC mains power voltage before applying power to the
Gaea fixtures accept AC mains power at 100-240 V nominal50/60 Hz. 00 not
apply AC mains power to the fixture at any other voltage than that specified on
the fixture's serial number label.
Data link
A DMX 512 data link is required in order to control a Gaea via DMX.
The Gara has 5-pin XLR connectors for DMX data input and output. The pin-out
on all connectors is pin 1= shield ,pin 2 = cold (-),and pin 3 = hot (+). Pins 4
and 5 in the 5-pin XLR connectors are not used in the Gaea but are available for
possible additional data signals as required by the DMX512-A standard.