Page 10 Page 11
StainlessLite Plus Direct
Basic Appliance
1. Hot water draw o (22mm) compression
2. Pressure and temperature relief valve
89-96°/6 bar
3. Hot water secondary return 22mm
(not tted to smaller sizes, see table 1)
4. Immersion heater 1¾” BSP 3kW
(normally on-peak)
5. 22mm cold supply compression
6. Immersion heater 1¾” BSP 3kW
(normally o-peak)
Additional immersion heater 1¾” BSP 3kW
(normally o-peak - 400 litre model only)
Part G3 loose components supplied in a
separate box
A. Combination inlet group incorporating
pressure reducing valve, strainer, check
valve, balance cold take o point, expansion
relief valve and expansion vessel connection
points.
B. Potable expansion vessels c/w exible hose
and integral wall bracket
C. Tundish
StainlessLite Plus Indirect
Basic Appliance
1. Hot water draw o (22mm) compression
2. Lift up temperature & pressure relief valve
89-96°/6 bar
3. Hot water secondary return 22mm
(not tted to smaller sizes, see table 2)
4. Immersion heater 1¾” BSP 3kW
5. 22mm cold supply compression
6. Immersion heater 1¾” BSP 3kW
7. Dual control/overheat stat pocket (22mm)
8. Primary return (22mm)
- (28mm tails for 400 litre models)
9. Primary ow (22mm)
- (28mm tails for 400 litre models)
Part G3 loose components supplied in a
separate box
A. Combination inlet group incorporating
pressure reducing valve, strainer, check
valve, balance cold take o point, expansion
relief valve and expansion vessel connection
points.
B. Potable expansion vessels c/w exible hose
and integral wall bracket
C. Tundish
D. Dual control thermostat and combined
overheat thermostat
E. Two por t (22mm) zone valve for
primary circuit
F. Wiring junction box for primary system
1
2
5
3
4
6
1
2
3
4
7
5
6
8
9
1
2
5
3
4
11
9
6
12
12
10
7
8
StainlessLite Plus Direct Solar
Basic Appliance
1. Hot water draw o (22mm) compression
2. Lift up temperature & pressure relief valve
89-96°/6 bar
3. Hot water secondary return 22mm
(not tted to smaller sizes, see table 1)
4. Immersion heater 1¾” BSP 3kW
(normally on-peak)
5. 22mm cold supply
6. Immersion heater 1¾” BSP 3kW
(normally o-peak)
7. Dual control/Overheat stat pocket (solar)
8. Solar coil return to panel collector (22mm)
compression
9.
Solar coil ow from panel (22mm) compression
10. Solar thermostat pocket
Part G3 loose components supplied in a
separate box
A.
Combination inlet group incorporating
pressure reducing valve, strainer, check valve,
balance cold take o point, expansion relief
valve and expansion vessel connection points.
B. Potable expansion vessels c/w exible hose
and integral wall bracket
C. Tundish
D. Dual control thermostat and combined
overheat thermostat
StainlessLite Plus Indirect Solar
Basic Appliance
1. Hot water draw o (22mm) compression
2. Lift up temperature & pressure relief valve
89-96°/6 bar
3. Hot water secondary return 22mm
(not tted to smaller sizes, see table 2)
4. Immersion heater 1¾” BSP 3kW
5. 22mm cold supply
6. Dual control/Overheat stat pocket (solar)
7. Primary return (22mm)
- (28mm tails for 400 litre models)
8. Primary ow (22mm)
- (28mm tails for 400 litre models)
9. Dual control/Overheat stat pocket (boiler)
10. Solar coil return to panel collector (22mm)
compression
11.
Solar coil ow from panel (22mm) compression
12. Solar thermostat pocket
Part G3 loose components supplied in a
separate box
A.
Combination inlet group incorporating
pressure reducing valve, strainer, check valve,
balance cold take o point, expansion relief
valve and expansion vessel connection points.
B. Potable expansion vessels c/w exible hose
and integral wall bracket
C. Tundish
D. Dual control thermostat and combined
overheat thermostat (x2)
E. Two por t (22mm) zone valve for
primary circuit
F. Wiring junction box for primary system
1
2
5
3
4
9
10
10
6
8
7
DESIGN DESIGN
SYSTEM DESIGN SYSTEM DESIGN