ADDENDUM INSTRUCTIONS
FOR SOLAR APPLIANCE
PLEASE LEAVE THESE INSTRUCTIONS IN THE POCKET PROVIDED ON
THE BACK OF THE FRONT PANEL
A SEALED SYSTEM CENTRAL HEATING AND MAINS
PRESSURE HOT WATER SUPPLY APPLIANCE WITH
THERMAL STORE DESIGNED SPECIFICALLY FOR USE
WITH SOLAR ENERGY
THESE INSTRUCTIONS MUST BE READ IN
CONJUNCTION WITH THE STANDARD
BOILERMATE A-CLASS SP
DESIGN, INSTALLATION AND SERVICING
INSTRUCTIONS BEFORE INSTALLATION
TM
benchmark
The code of practice for the installation,
commissioning & servicing of central heating systems
Models
BMA 200 SP - SOL
BMA 220 SP - SOL
BMA 240 SP - SOL
BoilerMate SP SOL
A - C L A S S
![](/html/7a/7a8f/7a8fe482d9da70c648a05f4b549906c976d00a54b732ed9182ee44705fc1bf13/bg2.png)
Page 2
CONTENTS
Section Page
1.0 Design 3
1.1 Introduction 3
1.2 Technical Data 5
Terms & Conditions 9
The Gledhill BoilerMate range is a WBS
listed product and complies with the WMA
Specification for integrated thermal storage
products. The principle was developed in
conjunction with British Gas. This product
is manufactured under an ISO 9001:2000
Quality System audited by BSI.
Patents Pending
The Gledhill Group’s first priority is to give a
high quality service to our customers.
Quality is built into every Gledhill product
and we hope you get satisfactory service
from Gledhill.
If not please let us know.
ISSUE 1: 10-06
Building Regulations and Benchmark Commissioning
The Building Regulations (England & Wales) require that the installation of a heating
appliance be notified to the relevant Local Authority Building Control Department.
From 1st April 2005 this can be achieved via a Competent Person Self Certification
Scheme as an option to notifying the Local Authority directly. Similar arrangements
will follow for Scotland and will apply in Northern Ireland from 1st January 06.
CORGI operates a Self Certification Scheme for gas heating appliances.
These arrangements represent a change from the situation whereby compliance with
the Building Regulations was accepted if the Benchmark Logbook was completed and
this was then left on site with the customer).
With the introduction of a self certification scheme, the Benchmark Logbook is being
replaced by a similar document in the form of a commissioning check list and a service
interval record is included with all gas appliance manuals. However, the relevant
Benchmark Logbook is still being included with all Thermal Storage products and
unvented cylinders.
Gledhill fully supports the Benchmark aims to improve the standards of installation
and commissioning of central heating systems in the UK and to encourage the regular
servicing of all central heating systems to ensure safety and efficiency.
Building Regulations require that the heating installation should comply with the
manufacturer’s instructions. It is therefore important that the commissioning check
list is completed by the competent installer. This check list only applies to installations
in dwellings or some related structures.
TM
benchmark
The code of practice for the installation,
commissioning & ser vicing of central heating systems
![](/html/7a/7a8f/7a8fe482d9da70c648a05f4b549906c976d00a54b732ed9182ee44705fc1bf13/bg3.png)
Page 3
BOILERMATE
A-CLASS
SP SOL
1.0 DESIGN
1.1 INTRODUCTION
The arrangement of a typical BoilerMate A-Class SP Solar installation is shown
schematically below. The basic unit which is covered by these instructions incorporates
the Danfoss SH - E01 solar controller.
The appliance generally follows the principles of the standard BoilerMate A-Class SP
appliance but is fitted with a separate set of coils to allow it to accept the maximum
amount of heat available from the solar panels/controls. This is then used to
supplement the hot water system.
The operation of the appliance/solar system is controlled by a number of sensors. The
location and reference numbers of the various sensors is shown eg 2, S6.
Sensors S1/S2, S3, S4, S5 and S6 are connected to the appliance control PCB which
operates all the heating and hot water functions as the basic BoilerMate appliance.
Sensors T1, T2 and T3 are connected to the Danfoss controller and operate all the
solar functions.
Model Selection Data Table/Weights
Model Reference BMA 200 SP SOL BMA 220 SP SOL BMA240 SP SOL
Dwelling type
Bedrooms 2-3 2-4 3-5
Bathrooms 1 2 2
En-Suite 2 1 2
Weight Empty (kg) - 79 -
Full (kg) - 260 -
SensorT3 provides a high temperature interlock
to de-activate the solar pump at a temperature
of 90ºC in the store.
Although sensors T1 and T2 are wired in to the
solar controller the cable provided for Sensor
T1 (3 metres long) may require to be extended
by the installer dependant on the location
of the solar panels/appliance. (2 x 0.75mm2
double insulated cable) up to a maximum total
length of 50 metres.
It is important that the installer checks the
hardness of the water supply and if this exceeds
200 ppm (mg/l) the factory fitted scale inhibitor
is ordered with the appliance at the time of
order to reduce the rate of accumulation of
scale in line with the requirements of the
Domestic Heating Compliance guide.
Solar
Controls
Solar
Collector
T1
V
V
Solar
Circuit
S4
S3
F & E Tank
(for thermal store)
S1/S2
T2
BoilerMate
A-Class SP Sol
T3
Heating/hot
water controls
(ACB)
Heating Return
Boiler
Mains
cold in
Hot out
Heating circuit
Sealed system kit
(available as an
optional extra)
Components fitted
within the
appliance
case
Note: The standard manual fill model BMA SP Sol
appliance is shown. A ballvalve and overflow are
available as an optional extra at the time of order
Schematic Diagram of Typical BoilerMate SP solar system
S6
S5
Automatic
Bypass
Heating Flow
![](/html/7a/7a8f/7a8fe482d9da70c648a05f4b549906c976d00a54b732ed9182ee44705fc1bf13/bg4.png)
Page 4
The above dimensions do not include the
100mm high installation base.
The above dimensions include the 100mm high
installation base and assume the F & E cistern is
in the same cupboard.
Note: Add 100mm to the above minimum
cupboard dimensions if a ballvalve and
overflow are being fitted.
Options at Extra Cost
See standard BoilerMate A-Class SP model
manual for details of the above.
1.0 DESIGN
B
E
600mm min clear opening - if door is
located directly in front of the
appliance.
Maintenance
access
*Increase to 350mm to
provide the minimum
maintenance access to
comply with the Water
Regulations if a ballvalve
and overflow are being
fitted.
F
C
300mm
420mm
280mm
600mm
100mm
*250mm
D
A
F & E Cistern
F & E Cistern
BoilerMate A-Class Solar
Appliance Dimensions
Model Height (A) Width (B) Depth (C)
BMA 200-SP SOL 1330 560 620
BMA 220-SP SOL 1330 560 620
BMA 240-SP SOL 1575 560 620
Minimum Cupboard Dimensions
Model Height (D) Width (E) Depth (F)
BMA 200-SP SOL 1825 660 630
BMA 220-SP SOL 1980 660 630
BMA 240-SP SOL 2225 660 630
1.0 INTRODUCTION