Gleamous DSK-45EP Instruction Manual

Instant Hot Water Heater
For proper operation and maintenance please
Read the instruction manual before installation.
www.gleamoushotwater.com.au
Instruction Manual
DSK - 45EP
88
240V~
50Hz
L
N E
1
Thank you for your choice of our products.To enjoy the service of this unit, Please read this manual carefully and follow the instruction rules.
I. Product Feartures
1. Energy-saving 4. Endless Hot warter
2. Supply hot water
on-demand
3. Easy operation 6. LED Temperature display
5. 240 volt 15amp
II. SCHEMATIC WIRING DIAGRAM FOR DSK-45EP
Resid ual cur rent pr otect ive dev ices
Contr ol PC B
Temper ature indicator
Heati ng elem ent
SCHEMATIC WI RING DIAGRAM FO R DSK-45EP
1
2
3
IIITECHNICAL PARAMETERS
DSK-45EP
240V~
50Hz
3.3kW
IPX5
182×83× 244mm
0KPa
Model
Voltage
Frequency
Power
Splash proof
Dimension
Rated Pressure
2
IV. Part Designation and Installation Diagram
88
1
2
6
3
DSK-45EP
4
N L E
5
LEA KAGE PRO TEATIO N SWI TCH
1. Mains Pressure Cold Water Inlet
2. Adjustable Temperature Setting
3. Safety Cover
4. Hot Water Supply Outlet
5. 15 AMP power cable
6. Digital Temperature display
Fig2
8mm x 25m m
Expan sion Bo lt
Mason ary Wall or Plast er boar d
8mm x 25m m
Expan sion Bo lt
10cm
2
4
cm
2
4
cm
10
Fixing Holes for fixed water Heater
V. Installation procedure
1. The unit must only be installed by a licenced Electrical Contractor.
2. A earth leakage circuit breaker with 30mA is required to install for the circuit controlling this unit.
3. The electric water heater should be wall-mounted installed. First determine the right position for installation of the unit (See fig 2). Mark
& drill three holes(8mmx25), insert the expansion bolt on the top, keep
Fig1
Installation diagram
Installation di agram of DSK-45 EP
Loading...
+ 5 hidden pages