Glastender UCR24X-L, UCR24X-R Operation Manual

Operation Manual, Parts Directory and Price List
UndercoUnter refrigerator
UCR24X-L, UCR24X-R, UCR24S-L, & UCR24S-R
IMPORTANT!!
Please review the important warranty information on page 4. If you believe a
service call should be covered by the factory, please call the factory for authorization
between 8AM and 5PM EST, Monday through Friday.
Glastender, Inc. · North Michigan Road · Saginaw, MI · 48604-9780
800.748.0423 · 989.752.4275 · Fax 800.838.0888 / 989.752.4444 · www.glastender.com
Rev. 06-01-10
UCR24S-LUCR24X-L
© 2010 Glastender, Inc.
Ucr24 UndercoUnter refrigerator
STARTER
operation
The operating temperature range is 36°F (2°C) to 40°F (5°C). UCR24S models include an automatic defrost system. The refrigerator will defrost every six hours for approximately 20 minutes. During the defrost, the fan inside the cooler will remain on and the refrigeration system will turn off.
technical information
Electrical: 120 Volt AC, 1 Phase, 60 Hz. 4.7 full load Amps, 1/4HP A separate 15 Amp circuit is recommended. A 6-foot grounded cord and plug is included with self-contained models.
Plumbing:
Refrigerant:
cleaning instrUctions
Cleaning is essential to sustaining the integrity of your equipment and preventing corrosion.
ESTIMATED CLEANING TIME: 5 to 10 minutes per unit daily, 45 minutes quarterly FREQUENCY: Daily cleaning of exterior & door gaskets. Quarterly cleaning of interior, including shelves. PROCEDURE:
1. A non-chlorine based cleaner or mild detergent and warm water applied with a soft cloth or sponge to all contact surfaces.
2. Immediately rinse off cleaning agent(s), using clean warm water, clean soft cloth or sponge.
3. Dry with a soft clean cloth, removing standing water as soon as possible.
nOTES:
1. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or chlorine based cleaners on stainless steel surfaces, since they will break down
the passivity layer and allow corrosion to occur.
2. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite® pad for more stubborn stains. Always scrub with the direction of
the grain. Follow with a thorough cleaning as described above.
3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if not removed.
4. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to premature failure, since alcohol
and moisture build-up breaks down the gasket material.
Automatic condensate evaporator is included. No drain connection required.
10.0 oz, R134a, Operating pressure high is 186 PSIG, low is 88 PSIG.
sealing refrigerator to floor
To comply with NSF & health codes, the refrigerator base must be sealed to the floor using NSF listed sealant. Place a bead of sealant along outer edges of the base and remove excess with disposable towel. The floor sealing procedure does not apply to models that include legs or casters.
16ga Wire
MAIN
POWER
SUPPLY
CORD
115v AC
5.5amp
Wiring diagram
Ucr24 m
odels
60hz
BALLAST
BLACK
BLACK
WHITE
GREEN
CONDENSER FAN
BLACK
COM
RUN
LIGHT SWITCH
BLACK
OVERLOAD
START
RED
BLACK
WHITE
RELAY
STARTER
BLUE
S
LIGHT
EVAPORATOR FAN
BLUE
YELLOW
WHITE
WHITE
WHITE
ORANGE
DEFROST TIMER
4 32 1
BLUE
ORANGE
THERMOSTAT
COMPRESSOR
ALL WIRE TO BE 16 GA.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
2
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
Loading...
+ 2 hidden pages